scholarly journals Characterization of Photoactivity of Nanostructured BiVO4 at Polarized Liquid–Liquid Interfaces by Scanning Electrochemical Microscopy

2017 ◽  
Vol 121 (46) ◽  
pp. 25941-25948 ◽  
Author(s):  
Shokoufeh Rastgar ◽  
Gunther Wittstock
Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1132 ◽  
Author(s):  
Rejane M. P. da Silva ◽  
Javier Izquierdo ◽  
Mariana X. Milagre ◽  
Abenchara M. Betancor-Abreu ◽  
Isolda Costa ◽  
...  

Amperometric and potentiometric probes were employed for the detection and characterization of reactive sites on the 2098-T351 Al-alloy (AA2098-T351) using scanning electrochemical microscopy (SECM). Firstly, the probe of concept was performed on a model Mg-Al galvanic pair system using SECM in the amperometric and potentiometric operation modes, in order to address the responsiveness of the probes for the characterization of this galvanic pair system. Next, these sensing probes were employed to characterize the 2098-T351 alloy surface immersed in a saline aqueous solution at ambient temperature. The distribution of reactive sites and the local pH changes associated with severe localized corrosion (SLC) on the alloy surface were imaged and subsequently studied. Higher hydrogen evolution, lower oxygen depletion and acidification occurred at the SLC sites developed on the 2098-T351 Al-alloy.


2020 ◽  
Vol MA2020-02 (1) ◽  
pp. 159-159
Author(s):  
Di Huang ◽  
Chaiwat Engtrakul ◽  
Sanjini U. Nanayakkara ◽  
Hongmei Luo ◽  
Robert Tenent

2000 ◽  
Vol 483 (1-2) ◽  
pp. 163-173 ◽  
Author(s):  
Jörg Strutwolf ◽  
Anna L Barker ◽  
Marylou Gonsalves ◽  
Daren J Caruana ◽  
Patrick R Unwin ◽  
...  

2014 ◽  
Vol 707 ◽  
pp. 113-116 ◽  
Author(s):  
Shou Huan Zhao ◽  
Ji Yong Zheng ◽  
Jing Ya Yang ◽  
Cun Guo Lin ◽  
Wei Wang ◽  
...  

The alternating current scanning electrochemical microscopy (AC-SECM) is an important method to characterize the electrochemical activity of living cells. In this paper, we apply AC-SECM to measure the electrochemical activity of diatom biofilm. We find that the diatom biofilm presents insulating effect to decrease the current, when the electrode is close to the biofilm. The alternating current impedance of diatom biofilm is overall smaller than that of the bare glass. To investigate the possible effect of chemical stimulus on cellular activity, the diatoms were immersed into paeonol solution (100 μg/mL), and AC-SECM imaging experiments were conducted when immersion time reached 20 h, 25 h and 35 h. The AC measurements performed at high frequencies show that phase angle decreases over time, which preliminarily indicates that the cellular activity of diatoms is affected by paeonol.


2006 ◽  
Vol 78 (15) ◽  
pp. 5436-5442 ◽  
Author(s):  
Maurizio R. Gullo ◽  
Patrick L. T. M. Frederix ◽  
Terunobu Akiyama ◽  
Andreas Engel ◽  
Nico F. deRooij ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document