Use of a new variable wavelength detector in high performance liquid chromatography

1974 ◽  
Vol 46 (6) ◽  
pp. 743-746 ◽  
Author(s):  
C. David. Carr
2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
James Prah ◽  
Elvis Ofori Ameyaw ◽  
Richmond Afoakwah ◽  
Patrick Fiawoyife ◽  
Ernest Oppong-Danquah ◽  
...  

Most prescribers and patients in Ghana now opt for the relatively expensive artemether/lumefantrine rather than artesunate-amodiaquine due to undesirable side effects in the treatment of uncomplicated malaria. The study sought to determine the existence of substandard and/or counterfeit artemether-lumefantrine tablets and suspension as well as artemether injection on the market in Cape Coast. Six brands of artemether-lumefantrine tablets, two brands of artemether-lumefantrine suspensions, and two brands of artemether injections were purchased from pharmacies in Cape Coast for the study. The mechanical properties of the tablets were evaluated. The samples were then analyzed for the content of active ingredients using High Performance Liquid Chromatography with a variable wavelength detector. None of the samples was found to be counterfeit. However, the artemether content of the samples was variable (93.22%−104.70% of stated content by manufacturer). The lumefantrine content of the artemether/lumefantrine samples was also variable (98.70%–111.87%). Seven of the artemether-lumefantrine brands passed whilst one failed the International Pharmacopoeia content requirements. All brands of artemether injections sampled met the International Pharmacopoeia content requirement. The presence of a substandard artemether-lumefantrine suspension in the market should alert regulatory bodies to be more vigilant and totally flush out counterfeit and substandard drugs from the Ghanaian market.


2007 ◽  
Vol 177 (4S) ◽  
pp. 295-295
Author(s):  
Michael Mullerad ◽  
Haleem J. Issaq ◽  
Alexander Kravtsov ◽  
Timothy Waybright ◽  
Brian Luke ◽  
...  

2013 ◽  
Vol 83 (2) ◽  
pp. 122-128 ◽  
Author(s):  
Cécile Renaud ◽  
Jacques Berger ◽  
Arnaud Laillou ◽  
Sylvie Avallone

Vitamin A deficiency is still one of the major public health problems in least developed countries. Fortification of vegetable oils is a strategy implemented worldwide to prevent this deficiency. For a fortification program to be effective, regular monitoring is necessary to control food quality in the producing units. The reference methods for vitamin A quantification are expensive and time-consuming. A rapid method should be useful for regular assessment of vitamin A in the oil industry. A portable device was compared to high-performance liquid chromatography (HPLC) for three plant oils (rapeseed, groundnut, and soya). The device presented a good linearity from 3 to 30 mg retinol equivalents per kg (mg RE.kg- 1). Its limits of detection and quantification were 3 mg RE.kg- 1 for groundnut and rapeseed oils and 4 mg RE.kg- 1 for soya oil. The intra-assay precision ranged from 1.48 % to 3.98 %, considered satisfactory. Accuracy estimated by the root mean squares error ranged from 3.99 to 5.49 and revealed a lower precision than HPLC (0.4 to 2.25). Although it offers less precision than HPLC, the device estimates quickly the vitamin A content of the tested oils from 3 or 4 to 15 mg RE.kg- 1.


Sign in / Sign up

Export Citation Format

Share Document