Comparative study on the critical current performance of Bi-2223/Ag and YBCO wires in low magnetic fields at liquid nitrogen temperature

2011 ◽  
Vol 471 (9-10) ◽  
pp. 293-296 ◽  
Author(s):  
F. Feng ◽  
T.-M. Qu ◽  
C. Gu ◽  
Y. Xin ◽  
W.-Z. Gong ◽  
...  
1987 ◽  
Vol 99 ◽  
Author(s):  
K. Tachikawa ◽  
M. Sugimoto ◽  
N. Sadakata ◽  
O. Kohno

Since discovery of the Y-Ba-Cu oxide compound showing superconductivity above liquid nitrogen temperature, intensive study has been under way to clarify nature of the high Tc oxides[l-4]. Much efforts were also made in the field of superconductor applications. A number of studies have been carried out by a powder metallurgical process of Y-Ba-Cu oxide compound wires, although, obtained critical current densities were still low at liquid nitrogen temperature[5–6]. Other techniques for wire fabrication is also being attempted[7–9]. In this study, Y-Ba-Cu oxide superconducting composite tapes were prepared by a diffusion process, which is one of the promising methods to obtain a high critical current density.


2013 ◽  
Vol 35 (7) ◽  
pp. 1294-1305 ◽  
Author(s):  
Dian-Sen Li ◽  
Chuang-Qi Zhao ◽  
Lei Jiang ◽  
Na Lu ◽  
Li-Ming Chen ◽  
...  

1987 ◽  
Vol 01 (07n08) ◽  
pp. 309-314 ◽  
Author(s):  
DING SHIYING ◽  
YAN JIALIE ◽  
SHI KEXING ◽  
YU ZHENG ◽  
CHENG JUN ◽  
...  

We have measured the magnetizations and determined the dependence of lower critical magnetic fields on temperature for high Tc Y-Ba-Cu-O Superconductor in liquid nitrogen temperature region. The structure examinations and the measurements of virgin magnetization in small fields show that our samples are made up of granules coupled to each other. Therefore the measured lower critical fields are attributed to the values at which flux enters the granulas.


1976 ◽  
Vol 54 (8) ◽  
pp. 827-829 ◽  
Author(s):  
S. A. Wender ◽  
L. Keszthelyi ◽  
J. A. Cameron

The integral rotation of the angular distribution of γ rays from the 749 keV level of 51 Cr excited by the (α,n) reaction in Ti5Fe95 and Ti5Ni95 targets has been used to measure the hyperfine magnetic fields at Cr nuclei in these alloys at liquid nitrogen temperature. The values are[Formula: see text]


1938 ◽  
Vol 34 (4) ◽  
pp. 625-633
Author(s):  
R. G. Stansfield

The magnetic anisotropy of crystals of calcite and sodium nitrate does not alter between room temperature and liquid nitrogen temperature. By using such diamagnetic crystals, it is easy to compare strong magnetic fields to 1 part in 1000. The effect is large enough for the measurement of fields of the order of 100 gauss, but in small fields the accuracy is limited by ferromagnetic contamination.


1992 ◽  
Vol 275 ◽  
Author(s):  
H. M. Duan ◽  
T. S. Kaplan ◽  
B. Dlugosch ◽  
A. M. Hermann

ABSTRACTLarge single crystals of Tl2Ba2CaCu2O8 superconductors were grown by a two step self-flux process. Crystals are plate-like. The in-plane crystal sizes are as large as 5mmX5mm and the thickness range from 0.01mm to 0.8mm. The critical currents were extracted from I-V curves measured at different temperatures. jc was about 2.4×104 A/cm2 at liquid nitrogen temperature.


2003 ◽  
Vol 17 (04n06) ◽  
pp. 966-971
Author(s):  
L. GIANNI ◽  
S. GINOCCHIO ◽  
L. ROGNONI ◽  
S. ZANNELLA ◽  
I. BALDI ◽  
...  

For power applications of HTS it is crucial to predict their AC losses in the typical operating conditions. We report measurements of energy losses in Bi-2223 multifilamentary tapes carrying AC currents and exposed to AC magnetic fields oriented perpendicular or parallel to their wide surface. Losses have been evaluated at liquid nitrogen temperature by transport and magnetisation measurements. The results have been compared to the experimental values obtained by calorimetric method the values estimated by a numerical model specifically developed of evaluation of AC losses in HTS tapes.


Sign in / Sign up

Export Citation Format

Share Document