scholarly journals Optimized cryo-focused ion beam sample preparation aimed at in situ structural studies of membrane proteins

2017 ◽  
Vol 197 (2) ◽  
pp. 73-82 ◽  
Author(s):  
Miroslava Schaffer ◽  
Julia Mahamid ◽  
Benjamin D. Engel ◽  
Tim Laugks ◽  
Wolfgang Baumeister ◽  
...  
Author(s):  
Jian-Shing Luo ◽  
Hsiu Ting Lee

Abstract Several methods are used to invert samples 180 deg in a dual beam focused ion beam (FIB) system for backside milling by a specific in-situ lift out system or stages. However, most of those methods occupied too much time on FIB systems or requires a specific in-situ lift out system. This paper provides a novel transmission electron microscopy (TEM) sample preparation method to eliminate the curtain effect completely by a combination of backside milling and sample dicing with low cost and less FIB time. The procedures of the TEM pre-thinned sample preparation method using a combination of sample dicing and backside milling are described step by step. From the analysis results, the method has applied successfully to eliminate the curtain effect of dual beam FIB TEM samples for both random and site specific addresses.


2016 ◽  
Vol 850 ◽  
pp. 722-727 ◽  
Author(s):  
Hui Wang ◽  
Shang Gang Xiao ◽  
Qiang Xu ◽  
Tao Zhang ◽  
Henny Zandbergen

The preparation of thin lamellas by focused ion beam (FIB) for MEMS-based in situ TEM experiments is time consuming. Typically, the lamellas are of ~5μm*10μm and have a thickness less than 100nm. Here we demonstrate a fast lamellas’ preparation method using special fast cutting by FIB of samples prepared by conventional TEM sample preparation by argon ion milling or electrochemical polishing methods. This method has been applied successfully on various materials, such as ductile metallic alloy Ti68Ta27Al5, brittle ceramics K0.5Na0.5NbO3-6%LiNbO3 and semiconductor Si. The thickness of the lamellas depends on the original TEM sample.


Author(s):  
R.J. Young ◽  
A. Buxbaum ◽  
B. Peterson ◽  
R. Schampers

Abstract Scanning transmission electron microscopy with scanning electron microscopes (SEM-STEM) has become increasing used in both SEM and dual-beam focused ion beam (FIB)-SEM systems. This paper describes modeling undertaken to simulate the contrast seen in such images. Such modeling provides the ability to help understand and optimize imaging conditions and also support improved sample preparation techniques.


Author(s):  
Jian-Shing Luo ◽  
Hsiu-Ting Lee ◽  
San-Lin Liew ◽  
Ching-Shan Sung ◽  
Yi-Jing Wu

Abstract The use of in-situ lift-out combined with focused ion beam milling has become a favorable choice as it offers several indispensable advantages compared to the conventional mechanical and ex-situ lift-out sample preparation techniques. This paper discusses the procedures of the multiple-post in-situ lift-out grids preparation using a dicing saw. In addition, a real case is described to show that the multiple-post in-situ lift-out grids have been successfully applied to failure analysis. The multiple-post in-situ lift-out grids provide more positions and flatter surfaces for TEM sample mounting. The flat surface greatly increases the mounting efficiency and success rate. For the real case application, a thick Al fluoride oxide layer and Al corrosion were found above the Al bond pads, which had NOSP problem, and their neighbor area, respectively.


1993 ◽  
Vol 21 (1-4) ◽  
pp. 375-378 ◽  
Author(s):  
L. Frey ◽  
W. Ergele ◽  
T. Falter ◽  
L. Gong ◽  
H. Ryssel