scholarly journals Patterns of Left Ventricular Geometry and Clinical Outcome After Transcatheter Aortic Valve Replacement

2019 ◽  
Vol 12 (4) ◽  
pp. 383-384
Author(s):  
Masahiko Asami ◽  
Thomas Pilgrim
Author(s):  
Jakob Ledwoch ◽  
Carolin Fröhlich ◽  
Ida Olbrich ◽  
Felix Poch ◽  
Ruth Thalmann ◽  
...  

Abstract Aims Atrial fibrillation (AF) is associated with increased mortality after transcatheter aortic valve replacement (TAVR). Cerebrovascular complications and bleeding events associated with anticoagulation therapy are discussed to be possible causes for this increased mortality. The present study sought to assess whether AF is associated with impaired left ventricular (LV) reverse remodeling representing another possible mechanism for poor outcome. Methods All patients who underwent TAVR in our institution and had 1-year echocardiography follow-up were included. LV mass index (LVMI) at baseline and follow-up as well as LVMI change at 1 year were assessed with respect to the presence of AF (either at baseline or during hospitalization after TAVR) and sinus rhythm (SR). Results A total of 213 patients (n = 95 in AF; n = 118 in SR) were enrolled in the present study. Patients with AF had higher LVMI at 1 year compared to those with SR (173 ± 61 g/m2 vs. 154 ± 55 g/m2; p = 0.02) and they showed lower relative LVMI change at 1 year (− 2 ± 28% vs. − 9 ± 29%; p = 0.04). In linear regression analysis, AF was independently associated with relative LVMI change (regression coefficient ß 0.076 [95% CI 0.001–0.150]; p = 0.04). With respect to clinical outcome depending on AF and LVMI regression, the Kaplan–Meier estimated event-free of death or cardiac rehospitalization at 3 years was lowest among patients with AF and no LVMI regression. Conclusions The present study identified a significant association of AF with changes in LVMI after TAVR, which was also shown to be associated with clinical outcome.


2021 ◽  
Vol 5 (5) ◽  
Author(s):  
Klaus-Dieter Hönemann ◽  
Steffen Hofmann ◽  
Frank Ritter ◽  
Gerold Mönnig

Abstract Background A rare, but serious, complication following transcatheter aortic valve replacement (TAVR) is the occurrence of an iatrogenic ventricular septal defect (VSD). Case summary We describe a case of an 80-year-old female who was referred with severe aortic stenosis for TAVR. Following thorough evaluation, the heart team consensus was to proceed with implantation via a transapical approach of an ACURATE neo M 25 mm valve (Boston Scientific, Natick, MA, USA). The valve was deployed harnessing transoesophageal echocardiographic (TOE) guidance under rapid pacing with post-dilation. Directly afterwards a very high VSD close to the aortic annulus was detected. As the patient was haemodynamically stable, the procedure was ended. The next day another TOE revealed a shunt volume (left-to-right ventricle) between 50% and 60%. Because the defect was partly located between the stent struts of the ACURATE valve decision was made to fix this leakage with implantation of a further valve and we chose an EVOLUT Pro 29 mm (Medtronic Inc., Minneapolis, MN, USA). The valve-in-valve was implanted 2–3 mm below the lower edge of the first valve, more towards the left ventricular outflow tract (LVOT) with excellent result: VSD was reduced to a very small residual shunt without any hemodynamic relevance. Discussion We suggest that an iatrogenic VSD located near the annulus may be treated percutaneously in a bail-out situation with implantation of a second valve that should be implanted slightly more into the LVOT to cover the VSD.


Sign in / Sign up

Export Citation Format

Share Document