In vivo corrosion of a magnesium plate-screw osteosynthesis system – soft and hard tissue response in a calvarial model on miniature pigs

Author(s):  
B. Schaller ◽  
P. Soong ◽  
E. Liu ◽  
T. Iizuka
2016 ◽  
Vol 44 (3) ◽  
pp. 309-317 ◽  
Author(s):  
Benoit Schaller ◽  
Nikola Saulacic ◽  
Thomas Imwinkelried ◽  
Stefan Beck ◽  
Edwin Wei Yang Liu ◽  
...  

2010 ◽  
Vol 95A (3) ◽  
pp. 940-949 ◽  
Author(s):  
Erhan Bat ◽  
Josée A. Plantinga ◽  
Martin C. Harmsen ◽  
Marja J. A. van Luyn ◽  
Jan Feijen ◽  
...  

Author(s):  
Mohammed Mousa Bakri ◽  
Sung Ho Lee ◽  
Jong Ho Lee

Abstract Background A compact passive oxide layer can grow on tantalum (Ta). It has been reported that this oxide layer can facilitate bone ingrowth in vivo though the development of bone-like apatite, which promotes hard and soft tissue adhesion. Thus, Ta surface treatment on facial implant materials may improve the tissue response, which could result in less fibrotic encapsulation and make the implant more stable on the bone surface. The purposes of this study were to verify whether surface treatment of facial implant materials using Ta can improve the biohistobiological response and to determine the possibility of potential clinical applications. Methods Two different and commonly used implant materials, silicone and expanded polytetrafluoroethylene (ePTFE), were treated via Ta ion implantation using a Ta sputtering gun. Ta-treated samples were compared with untreated samples using in vitro and in vivo evaluations. Osteoblast (MG-63) and fibroblast (NIH3T3) cell viability with the Ta-treated implant material was assessed, and the tissue response was observed by placing the implants over the rat calvarium (n = 48) for two different lengths of time. Foreign body and inflammatory reactions were observed, and soft tissue thickness between the calvarium and the implant as well as the bone response was measured. Results The treatment of facial implant materials using Ta showed a tendency toward increased fibroblast and osteoblast viability, although this result was not statistically significant. During the in vivo study, both Ta-treated and untreated implants showed similar foreign body reactions. However, the Ta-treated implant materials (silicone and ePTFE) showed a tendency toward better histological features: lower soft tissue thickness between the implant and the underlying calvarium as well as an increase in new bone activity. Conclusion Ta surface treatment using ion implantation on silicone and ePTFE facial implant materials showed the possibility of reducing soft tissue intervention between the calvarium and the implant to make the implant more stable on the bone surface. Although no statistically significant improvement was observed, Ta treatment revealed a tendency toward an improved biohistological response of silicone and ePTFE facial implants. Conclusively, tantalum treatment is beneficial and has the potential for clinical applications.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Christine L. Farnsworth ◽  
Peter O. Newton ◽  
Eric Breisch ◽  
Michael T. Rohmiller ◽  
Jung Ryul Kim ◽  
...  

Study Design. Combinations of metal implants (stainless steel (SS), titanium (Ti), and cobalt chrome (CC)) were placed in porcine spines. After 12 months, tissue response and implant corrosion were compared between mixed and single metal junctions. Objective. Model development and an attempt to determine any detriment of combining different metals in posterior spinal instrumentation. Methods. Yucatan mini-pigs underwent instrumentation over five unfused lumbar levels. A SS rod and a Ti rod were secured with Ti and SS pedicle screws, SS and Ti crosslinks, SS and CC sublaminar wires, and Ti sublaminar cable. The resulting 4 SS/SS, 3 Ti/Ti, and 11 connections between dissimilar metals per animal were studied after 12 months using radiographs, gross observation, and histology (foreign body reaction (FBR), metal particle count, and inflammation analyzed). Results. Two animals had constructs in place for 12 months with no complications. Histology of tissue over SS/SS connections demonstrated 11.1 ± 7.6 FBR cells, 2.1 ± 1.7 metal particles, and moderate to extensive inflammation. Ti/Ti tissue showed 6.3 ± 3.8 FBR cells, 5.2 ± 6.7 particles, and no to extensive inflammation (83% extensive). Tissue over mixed components had 14.1 ± 12.6 FBR cells and 13.4 ± 27.8 particles. Samples surrounding wires/cables versus other combinations demonstrated FBR (12.4 ± 13.5 versus 12.0 ± 9.6 cells, P = 0.96), particles (19.8 ± 32.6 versus 4.3 ± 12.7, P = 0.24), and inflammation (50% versus 75% extensive, P = 0.12). Conclusions. A nonfusion model was developed to study corrosion and analyze biological responses. Although no statistical differences were found in overlying tissue response to single versus mixed metal combinations, galvanic corrosion between differing metals is not ruled out. This pilot study supports further investigation to answer concerns when mixing metals in spinal constructs.


2010 ◽  
Vol 79 (4) ◽  
pp. 613-620 ◽  
Author(s):  
Lucie Urbanová ◽  
Robert Srnec ◽  
Pavel Proks ◽  
Ladislav Stehlík ◽  
Zdeněk Florian ◽  
...  

The study deals with the determination of mechanical properties, namely resistance to bending forces, of flexible buttress osteosynthesis using two different bone-implant constructs stabilizing experimental segmental femoral bone defects (segmental ostectomy) in a miniature pig ex vivo model using 4.5 mm titanium LCP and a 3 mm intramedullary pin (“plate and rod” construct) (PR-LCP), versus the 4.5 mm titanium LCP alone (A-LCP). The “plate and rod” fixation (PR-LCP) of the segmental femoral defect is significantly more resistant (p < 0.05) to bending forces (200 N, 300 N, and 500 N) than LCP alone (A-LCP). Stabilisation of experimental segmental lesions of the femoral diaphysis in miniature pigs by flexible bridging osteosynthesis 4.5 mm LCP in combination with the “plate and rod” construct appears to be a suitable fixation of non-reducible fractures where considerable strain of the implants by bending forces can be assumed. These findings will be used in upcoming in vivo experiments in the miniature pig to investigate bone defect healing after transplantation of mesenchymal stem cells in combination with biocompatible scaffolds.


Biomaterials ◽  
2005 ◽  
Vol 26 (9) ◽  
pp. 1043-1052 ◽  
Author(s):  
Shula Radin ◽  
Gehan El-Bassyouni ◽  
Edward J. Vresilovic ◽  
Evert Schepers ◽  
Paul Ducheyne

2021 ◽  
Vol 17 (9) ◽  
pp. 1812-1823
Author(s):  
Fei Liu ◽  
Xinyu Wang ◽  
Shujun Li ◽  
Yiheng Liao ◽  
Xinxin Zhan ◽  
...  

Ti–24Nb–4Zr–8Sn (Ti2448) alloys, with a relatively low elastic modulus and unique mechanical properties, are desirable materials for oral implantation. In the current study, a multifaceted strontium-incorporating nanotube coating was fabricated on a Ti2448 alloy (Ti2-NTSr) through anodization and hydrothermal procedures. In vitro, the Ti2-NTSr specimens demonstrated better osteogenic properties and more favorable osteoimmunomodulatory abilities. Moreover, macrophages on Ti2-NTSr specimens could improve the recruitment and osteogenic differentiation of osteoblasts. In vivo, dense clots with highly branched, thin fibrins and small pores existed on the Ti2-NTSr implant in the early stage after surgery. Analysis of the deposition of Ca and P elements, hard tissue slices and the bone-implant contact rate (BIC%) of the Ti2-NTSr implants also showed superior osseointegration. Taken together, these results demonstrate that the Ti2-NTSr coating may maximize the clinical outcomes of Ti2448 alloys for implantation applications.


Author(s):  
Ross S. Johnson ◽  
Terry W. Lewis ◽  
Elden G. Lampecht
Keyword(s):  

2019 ◽  
Vol 61 (1) ◽  
pp. 14-26 ◽  
Author(s):  
Michalina Gramatyka ◽  
ᴌukasz Boguszewicz ◽  
Mateusz Ciszek ◽  
Dorota Gabryś ◽  
Roland Kulik ◽  
...  

Abstract Ionizing radiation may cause cardiotoxicity not only at high, but even at low (considered as harmless) doses, yet the molecular mechanisms of the heart’s response to low doses are not clear. In this work, we used high-resolution nuclear magnetic resonance (NMR) spectroscopy to detect the early and late effects of radiation on the metabolism of murine hearts. The hearts of C57Bl/6NCrl female mice were irradiated in vivo with single 0.2 Gy or 2 Gy doses using 6 MV photons, then tissues were collected 48 h and 20 weeks after exposure. The most distinct changes in the profile of polar metabolites were detected 48 h after irradiation with 2 Gy, and included increased levels of pantothenate and glutamate as well as decreased levels of alanine, malonate, acetylcarnitine, glycine and adenosine. Significant effects of the 2 Gy dose were also observed 20 weeks after irradiation and included decreased levels of glutamine and acetylcarnitine when compared with age-matched controls. Moreover, several differences were observed between hearts irradiated with 2 Gy and analyzed either 48 h or 20 weeks after the exposure, which included changes in levels of acetylcarnitine, alanine, glycine, glutamate, glutamine, formate, myo-inositol and trimethylamine. No statistically significant effects induced by the 0.2 Gy dose were observed 20 weeks after irradiation. In general, radiation-affected compounds were associated with energy metabolism, fatty acid beta-oxidation, oxidative stress and damage to cell structures. At the same time, radiation-related effects were not detected at the level of tissue histology, which indicated a higher sensitivity of metabolomics-based tests for cardiac tissue response to radiation.