3D numerical analysis of column shortening and shore safety under construction of high-rise building

2017 ◽  
Vol 150 ◽  
pp. 242-255 ◽  
Author(s):  
Yun Lee ◽  
Jin-Keun Kim ◽  
Hyun-Cheol Seol ◽  
Joo-Kyoung Yang ◽  
Ki-Jung Kim
2019 ◽  
Vol 262 ◽  
pp. 04002
Author(s):  
Leszek Chomacki

One of the basic roles of foundations is to safely transfer loads from the structure to the subsoil in a controlled manner. Often a key parameter in deciding whether the foundation was designed correctly is the value of settlement of the building and the ground around it. This paper attempts to numerically reproduce the measured settlement of a high-rise building using geotechnical parameters already available. For this purpose, numerical calculations were carried out using two constitutive soil models: the elastic-perfectly plastic model with Mohr-Coulomb plastic criteria (MC) model and the Hardening Soil (HS) model. The resulting settlement values were compared with surveying measurements taken during and after the building’s construction. In the summary the results obtained with the use of different constitutive models, the calculation process and the adopted soil parameters are analysed and discussed.


2021 ◽  
Vol 28 (2) ◽  
pp. 125-132
Author(s):  
Alif Muhammad Reza ◽  
Herlien D. Setio

Abstract Various studies have been carried out to evaluate the feasibility and effectiveness of the story isolation system. The results obtained are also quite impressive, where the story isolation system gave a better story drift reduction than the base isolation system. However, these studies only focused on low-rise buildings, even though the story isolation system will be more engaging if it could also be compatible with high-rise buildings. In this study, a numerical analysis will be carried out on 30-, 40-, 50-, and 60-story buildings to evaluate the story isolator’s location, so that the system gives an optimum reduction of story drift and story shear. Then a general solution is sought to become a reference for buildings with different plans and heights. Keywords: Story isolation system, story isolator optimum location, high-rise building. Abstract Berbagai penelitian telah dilakukan untuk mengevaluasi kelayakan dan efektivitas sistem isolasi tingkat. Hasil yang diperoleh juga cukup mengesankan, dimana sistem isolasi tingkat memberikan reduksi simpangan antar tingkat yang lebih baik dibandingkan dengan sistem isolasi dasar. Namun, studi tersebut hanya berfokus pada bangunan bertingkat rendah, padahal sistem isolasi lantai akan lebih menarik jika dapat juga digunakan pada bangunan bertingkat tinggi. Dalam studi ini, analisis numerik akan dilakukan pada bangunan berlantai 30, 40, 50, dan 60 untuk mengevaluasi lokasi isolator tingkat yang memberikan reduksi simpangan tingkat dan geser tingkat terbesar. Kemudian dicari solusi umum untuk menjadi acuan untuk bangunan dengan denah dan ketinggian yang berbeda. Kata kunci: Sistem isolasi tingkat, lokasi optimum isolator tingkat, bangunan bertingkat tinggi.


2013 ◽  
Vol 281 ◽  
pp. 639-644 ◽  
Author(s):  
V.N. Alekhin ◽  
A.A. Antipin ◽  
S.N. Gorodilov

In the paper the wind loads on 52 flore building "Iset Tower" are investigated. Distribution of pressure to the building and velocities are presented. Performed calculations show qualitative agreement with experimental results. According to the results of numerical simulation of wind effects it can be concluded that both aerodynamic experiments and numerical analysis are needed in the design. If there is coincidence of experimental and numerical results then they can be used to calculate the skeleton of the building.