Infrared chemical imaging: Spatial resolution evaluation and super-resolution concept

2010 ◽  
Vol 674 (2) ◽  
pp. 220-226 ◽  
Author(s):  
Marc Offroy ◽  
Yves Roggo ◽  
Peyman Milanfar ◽  
Ludovic Duponchel
2019 ◽  
Author(s):  
Le Wang ◽  
Devon Jakob ◽  
Haomin Wang ◽  
Alexis Apostolos ◽  
Marcos M. Pires ◽  
...  

<div>Infrared chemical microscopy through mechanical probing of light-matter interactions by atomic force microscopy (AFM) bypasses the diffraction limit. One increasingly popular technique is photo-induced force microscopy (PiFM), which utilizes the mechanical heterodyne signal detection between cantilever mechanical resonant oscillations and the photo induced force from light-matter interaction. So far, photo induced force microscopy has been operated in only one heterodyne configuration. In this article, we generalize heterodyne configurations of photoinduced force microscopy by introducing two new schemes: harmonic heterodyne detection and sequential heterodyne detection. In harmonic heterodyne detection, the laser repetition rate matches integer fractions of the difference between the two mechanical resonant modes of the AFM cantilever. The high harmonic of the beating from the photothermal expansion mixes with the AFM cantilever oscillation to provide PiFM signal. In sequential heterodyne detection, the combination of the repetition rate of laser pulses and polarization modulation frequency matches the difference between two AFM mechanical modes, leading to detectable PiFM signals. These two generalized heterodyne configurations for photo induced force microscopy deliver new avenues for chemical imaging and broadband spectroscopy at ~10 nm spatial resolution. They are suitable for a wide range of heterogeneous materials across various disciplines: from structured polymer film, polaritonic boron nitride materials, to isolated bacterial peptidoglycan cell walls. The generalized heterodyne configurations introduce flexibility for the implementation of PiFM and related tapping mode AFM-IR, and provide possibilities for additional modulation channel in PiFM for targeted signal extraction with nanoscale spatial resolution.</div>


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
C. Callenberg ◽  
A. Lyons ◽  
D. den Brok ◽  
A. Fatima ◽  
A. Turpin ◽  
...  

AbstractImaging across both the full transverse spatial and temporal dimensions of a scene with high precision in all three coordinates is key to applications ranging from LIDAR to fluorescence lifetime imaging. However, compromises that sacrifice, for example, spatial resolution at the expense of temporal resolution are often required, in particular when the full 3-dimensional data cube is required in short acquisition times. We introduce a sensor fusion approach that combines data having low-spatial resolution but high temporal precision gathered with a single-photon-avalanche-diode (SPAD) array with data that has high spatial but no temporal resolution, such as that acquired with a standard CMOS camera. Our method, based on blurring the image on the SPAD array and computational sensor fusion, reconstructs time-resolved images at significantly higher spatial resolution than the SPAD input, upsampling numerical data by a factor $$12 \times 12$$ 12 × 12 , and demonstrating up to $$4 \times 4$$ 4 × 4 upsampling of experimental data. We demonstrate the technique for both LIDAR applications and FLIM of fluorescent cancer cells. This technique paves the way to high spatial resolution SPAD imaging or, equivalently, FLIM imaging with conventional microscopes at frame rates accelerated by more than an order of magnitude.


2021 ◽  
Vol 13 (10) ◽  
pp. 1944
Author(s):  
Xiaoming Liu ◽  
Menghua Wang

The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite has been a reliable source of ocean color data products, including five moderate (M) bands and one imagery (I) band normalized water-leaving radiance spectra nLw(λ). The spatial resolutions of the M-band and I-band nLw(λ) are 750 m and 375 m, respectively. With the technique of convolutional neural network (CNN), the M-band nLw(λ) imagery can be super-resolved from 750 m to 375 m spatial resolution by leveraging the high spatial resolution features of I1-band nLw(λ) data. However, it is also important to enhance the spatial resolution of VIIRS-derived chlorophyll-a (Chl-a) concentration and the water diffuse attenuation coefficient at the wavelength of 490 nm (Kd(490)), as well as other biological and biogeochemical products. In this study, we describe our effort to derive high-resolution Kd(490) and Chl-a data based on super-resolved nLw(λ) images at the VIIRS five M-bands. To improve the network performance over extremely turbid coastal oceans and inland waters, the networks are retrained with a training dataset including ocean color data from the Bohai Sea, Baltic Sea, and La Plata River Estuary, covering water types from clear open oceans to moderately turbid and highly turbid waters. The evaluation results show that the super-resolved Kd(490) image is much sharper than the original one, and has more detailed fine spatial structures. A similar enhancement of finer structures is also found in the super-resolved Chl-a images. Chl-a filaments are much sharper and thinner in the super-resolved image, and some of the very fine spatial features that are not shown in the original images appear in the super-resolved Chl-a imageries. The networks are also applied to four other coastal and inland water regions. The results show that super-resolution occurs mainly on pixels of Chl-a and Kd(490) features, especially on the feature edges and locations with a large spatial gradient. The biases between the original M-band images and super-resolved high-resolution images are small for both Chl-a and Kd(490) in moderately to extremely turbid coastal oceans and inland waters, indicating that the super-resolution process does not change the mean values of the original images.


2021 ◽  
Vol 57 (28) ◽  
pp. 3492-3495
Author(s):  
Zhaoshuai Gao ◽  
Pei Wu ◽  
Lixin Yin ◽  
Bin Kang ◽  
Hong-Yuan Chen ◽  
...  

Super-resolution plasmonic scattering imaging was realized with a 65 nm spatial resolution on 50 nm gold nanoparticles.


Author(s):  
R. S. Hansen ◽  
D. W. Waldram ◽  
T. Q. Thai ◽  
R. B. Berke

Abstract Background High-resolution Digital Image Correlation (DIC) measurements have previously been produced by stitching of neighboring images, which often requires short working distances. Separately, the image processing community has developed super resolution (SR) imaging techniques, which improve resolution by combining multiple overlapping images. Objective This work investigates the novel pairing of super resolution with digital image correlation, as an alternative method to produce high-resolution full-field strain measurements. Methods First, an image reconstruction test is performed, comparing the ability of three previously published SR algorithms to replicate a high-resolution image. Second, an applied translation is compared against DIC measurement using both low- and super-resolution images. Third, a ring sample is mechanically deformed and DIC strain measurements from low- and super-resolution images are compared. Results SR measurements show improvements compared to low-resolution images, although they do not perfectly replicate the high-resolution image. SR-DIC demonstrates reduced error and improved confidence in measuring rigid body translation when compared to low resolution alternatives, and it also shows improvement in spatial resolution for strain measurements of ring deformation. Conclusions Super resolution imaging can be effectively paired with Digital Image Correlation, offering improved spatial resolution, reduced error, and increased measurement confidence.


2021 ◽  
Vol 8 (1) ◽  
pp. 28
Author(s):  
Cinzia Lastri ◽  
Gabriele Amato ◽  
Massimo Baldi ◽  
Tiziano Bianchi ◽  
Maria Fabrizia Buongiorno ◽  
...  

This paper describes the activities related to a feasibility study for an Earth observation optical payload, operating in the medium infrared, based on super-resolution and compressive sensing techniques. The presented activities are running in the framework of the ASI project SISSI, aiming to improve ground spatial resolution and mitigate saturation/blooming effects. The core of the payload is a spatial light modulator (SLM): a bidimensional array of micromirrors electronically actuated. Thanks to compressive sensing approach, the proposed payload eliminates the compression board, saving mass, memory and energy consumption.


2018 ◽  
Vol 10 (8) ◽  
pp. 1212 ◽  
Author(s):  
Xiaohong Yang ◽  
Zhong Xie ◽  
Feng Ling ◽  
Xiaodong Li ◽  
Yihang Zhang ◽  
...  

Super-resolution land cover mapping (SRM) is a method that aims to generate land cover maps with fine spatial resolutions from the original coarse spatial resolution remotely sensed image. The accuracy of the resultant land cover map produced by existing SRM methods is often limited by the errors of fraction images and the uncertainty of spatial pattern models. To address these limitations in this study, we proposed a fuzzy c-means clustering (FCM)-based spatio-temporal SRM (FCM_STSRM) model that combines the spectral, spatial, and temporal information into a single objective function. The spectral term is constructed with the FCM criterion, the spatial term is constructed with the maximal spatial dependence principle, and the temporal term is characterized by the land cover transition probabilities in the bitemporal land cover maps. The performance of the proposed FCM_STSRM method is assessed using data simulated from the National Land Cover Database dataset and real Landsat images. Results of the two experiments show that the proposed FCM_STSRM method can decrease the influence of fraction errors by directly using the original images as the input and the spatial pattern uncertainty by inheriting land cover information from the existing fine resolution land cover map. Compared with the hard classification and FCM_SRM method applied to mono-temporal images, the proposed FCM_STSRM method produced fine resolution land cover maps with high accuracy, thus showing the efficiency and potential of the novel approach for producing fine spatial resolution maps from coarse resolution remotely sensed images.


2013 ◽  
Vol 135 (2) ◽  
Author(s):  
Julian Le Rouzic ◽  
Tom Reddyhoff

Surface temperature measurements within sliding contacts are useful since interfacial heat dissipation is closely linked to tribological behavior. One of the most powerful techniques for such measurements is in-contact temperature mapping whereby a sliding contact is located beneath an infrared microscope. In this approach, one of the specimens must be transparent to infrared and coated such that radiation components can be distinguished and isolated from background values. Despite its effectiveness, a number of practical constraints prevent this technique from being applied to rough surfaces—a research area where temperature maps could provide much needed two-dimension input data to inform mixed and boundary friction models. The research described in this paper is aimed at improving the infrared temperature mapping technique in terms of validity, robustness, and spatial resolution, so that measurements of rough surfaces contacts can be made. First, Planck's law is applied in order to validate the use of surface coating as a means of removing background radiation. Second, a refined method of calibration is put forward and tested, which negates the need for a soft aluminum coating and hence enables rough surfaces to be measured. Finally, the use of super-resolution algorithms is assessed in order extend spatial resolution beyond the current limit of 6 μm.


Author(s):  
Robert A. Lazenby ◽  
Ryan J. White

This review discusses a broad range of recent advances (2013-2017) of chemical imaging using electrochemical methods, with a particular focus on techniques that have been applied to study cellular processes, or techniques that show promise for use in this field in the future. Non-scanning techniques such as microelectrode arrays (MEAs) offer high time-resolution (&lt; 10 ms) imaging, however at reduced spatial resolution. In contrast, scanning electrochemical probe microscopies (SEPMs) offer higher spatial resolution (as low as a few nm per pixel) imaging, with images collected typically over many minutes. Recent significant research efforts to improve the spatial resolution of SEPMs using nanoscale probes, and to improve the temporal resolution using fast scanning have resulted in movie (multiple frame) imaging with frame rates as low as a few seconds per image. Many SEPM techniques lack chemical specificity or have poor selectivity (defined by the choice of applied potential for redox-active species). This can be improved using multifunctional probes, ion-selective electrodes and tip-integrated biosensors, although additional effort may be required to preserve sensor performance after miniaturization of these probes. We discuss advances to the field of electrochemical imaging, and technological developments which are anticipated to extend the range of processes that can be studied. This includes imaging cellular processes with increased sensor selectivity and at much improved spatiotemporal resolution than has been previously customary.


Sign in / Sign up

Export Citation Format

Share Document