True atomic resolution under ambient conditions obtained by atomic force microscopy in the contact mode

1999 ◽  
Vol 68 (4) ◽  
pp. 399-402 ◽  
Author(s):  
T. Schimmel ◽  
T. Koch ◽  
J. Küppers ◽  
M. Lux-Steiner
2001 ◽  
Vol 86 (7) ◽  
pp. 1287-1290 ◽  
Author(s):  
M. R. Jarvis ◽  
Rubén Pérez ◽  
M. C. Payne

Friction ◽  
2021 ◽  
Author(s):  
Xinfeng Tan ◽  
Dan Guo ◽  
Jianbin Luo

AbstractDynamic friction occurs not only between two contact objects sliding against each other, but also between two relative sliding surfaces several nanometres apart. Many emerging micro- and nano-mechanical systems that promise new applications in sensors or information technology may suffer or benefit from noncontact friction. Herein we demonstrate the distance-dependent friction energy dissipation between the tip and the heterogeneous polymers by the bimodal atomic force microscopy (AFM) method driving the second order flexural and the first order torsional vibration simultaneously. The pull-in problem caused by the attractive force is avoided, and the friction dissipation can be imaged near the surface. The friction dissipation coefficient concept is proposed and three different contact states are determined from phase and energy dissipation curves. Image contrast is enhanced in the intermediate setpoint region. The work offers an effective method for directly detecting the friction dissipation and high resolution images, which overcomes the disadvantages of existing methods such as contact mode AFM or other contact friction and wear measuring instruments.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Juan Gros-Otero ◽  
Samira Ketabi ◽  
Rafael Cañones-Zafra ◽  
Montserrat Garcia-Gonzalez ◽  
Cesar Villa-Collar ◽  
...  

Abstract Background To compare the anterior surface roughness of two commercially available posterior chamber phakic intraocular lenses (IOLs) using atomic force microscopy (AFM). Methods Four phakic IOLs were used for this prospective, experimental study: two Visian ICL EVO+ V5 lenses and two iPCL 2.0 lenses. All of them were brand new, were not previously implanted in humans, were monofocal and had a dioptric power of − 12 diopters (D). The anterior surface roughness was assessed using a JPK NanoWizard II® atomic force microscope in contact mode immersed in liquid. Olympus OMCL-RC800PSA commercial silicon nitride cantilever tips were used. Anterior surface roughness measurements were made in 7 areas of 10 × 10 μm at 512 × 512 point resolution. The roughness was measured using the root-mean-square (RMS) value within the given regions. Results The mean of all anterior surface roughness measurements was 6.09 ± 1.33 nm (nm) in the Visian ICL EVO+ V5 and 3.49 ± 0.41 nm in the iPCL 2.0 (p = 0.001). Conclusion In the current study, we found a statistically significant smoother anterior surface in the iPCL 2.0 phakic intraocular lenses compared with the VISIAN ICL EVO+ V5 lenses when studied with atomic force microscopy.


2000 ◽  
Vol 39 (Part 2, No. 2A) ◽  
pp. L113-L115 ◽  
Author(s):  
Kousuke Yokoyama ◽  
Taketoshi Ochi ◽  
Akira Yoshimoto ◽  
Yasuhiro Sugawara ◽  
Seizo Morita

1996 ◽  
Vol 273 (1-2) ◽  
pp. 138-142 ◽  
Author(s):  
Seizo Morita ◽  
Satoru Fujisawa ◽  
Eigo Kishi ◽  
Masahiro Ohta ◽  
Hitoshi Ueyama ◽  
...  

1995 ◽  
Vol 413 ◽  
Author(s):  
V. Shivshankar ◽  
C. Sung ◽  
J. Kumar ◽  
S. K. Tripathy ◽  
D. J. Sandman

ABSTRACTWe have studied the surface morphology of free standing single crystals of thermochromic polydiacetylenes (PDAs), namely, ETCD and IPUDO (respectively, the ethyl and isopropyl urethanes of 5,7-dodecadiyn-1,12-diol), by Atomic Force Microscopy (AFM) under ambient conditions. Micron scale as well as molecularly resolved images were obtained. The micron scale images indicate a variable surface, and the molecularly resolved images show a well defined 2-D lattice that is interpreted in terms of molecular models and known crystallographic data. Thereby information about surface morphology, which is crucial to potential optical device or chromic sensor performance is available. We also report the observation of a “macroscopic shattering” of the IPUDO monomer crystal during in-situ UV polymerization studies.


2008 ◽  
Vol 1143 ◽  
Author(s):  
Bijandra Kumar ◽  
Mickaël Castro ◽  
Jianbo Lu ◽  
Jean-François Feller

ABSTRACTOrganic vapour sensors based on poly (methylmethacrylate)-multi-wall carbon nanotubes (PMMA-CNT) conductive polymer nanocomposite (CPC) were developed via layer by layer technique by spray deposition. CPC Sensors were exposed to three different classes of solvents (chloroform, methanol and water) and their chemo-electrical properties were followed as a function of CNTcontent in dynamic mode. Detection time was found to be shorter than that necessary for full recovery of initial state. CNT real three dimensional network has been visualized by Atomic force microscopy in a field assisted intermittent contact mode. More interestingly real conductive network system and electrical ability of CPC have been explored by current-sensing atomic force microscopy (CS-AFM). Realistic effect of voltage on electrical conductivity has been found linear.


Sign in / Sign up

Export Citation Format

Share Document