scholarly journals Three-dimensional joit kinematics using bone surface registration: A computer assisted approach with an application to the wrist joint in vivo

Author(s):  
Joseph J. Crisco ◽  
Robert D. McGovern ◽  
Scott W. Wolfe
2006 ◽  
Vol 26 (12) ◽  
pp. 4539-4552 ◽  
Author(s):  
Keqin Zhang ◽  
Cielo Barragan-Adjemian ◽  
Ling Ye ◽  
Shiva Kotha ◽  
Mark Dallas ◽  
...  

ABSTRACT Within mineralized bone, osteocytes form dendritic processes that travel through canaliculi to make contact with other osteocytes and cells on the bone surface. This three-dimensional syncytium is thought to be necessary to maintain viability, cell-to-cell communication, and mechanosensation. E11/gp38 is the earliest osteocyte-selective protein to be expressed as the osteoblast differentiates into an osteoid cell or osteocyte, first appearing on the forming dendritic processes of these cells. Bone extracts contain large amounts of E11, but immunostaining only shows its presence in early osteocytes compared to more deeply embedded cells, suggesting epitope masking by mineral. Freshly isolated primary osteoblasts are negative for E11 expression but begin to express this protein in culture, and expression increases with time, suggesting differentiation into the osteocyte phenotype. Osteoblast-like cell lines 2T3 and Oct-1 also show increased expression of E11 with differentiation and mineralization. E11 is highly expressed in MLO-Y4 osteocyte-like cells compared to osteoblast cell lines and primary osteoblasts. Differentiated, mineralized 2T3 cells and MLO-Y4 cells subjected to fluid flow shear stress show an increase in mRNA for E11. MLO-Y4 cells show an increase in dendricity and elongation of dendrites in response to shear stress that is blocked by small interfering RNA specific to E11. In vivo, E11 expression is also increased by a mechanical load, not only in osteocytes near the bone surface but also in osteocytes more deeply embedded in bone. Maximal expression is observed not in regions of maximal strain but in a region of potential bone remodeling, suggesting that dendrite elongation may be occurring during this process. These data suggest that osteocytes may be able to extend their cellular processes after embedment in mineralized matrix and have implications for osteocytic modification of their microenvironment.


2005 ◽  
Vol 119 (9) ◽  
pp. 693-698 ◽  
Author(s):  
Beom-Cho Jun ◽  
Sun-Wha Song ◽  
Ju-Eun Cho ◽  
Chan-Soon Park ◽  
Dong-Hee Lee ◽  
...  

The aim of this study was to investigate the usefulness of a three-dimensional (3D) reconstruction of computed tomography (CT) images in determining the anatomy and topographic relationship between various important structures. Using 40 ears from 20 patients with various otological diseases, a 3D reconstruction based on the image data from spiral high-resolution CT was performed by segmentation, volume-rendering and surface-rendering algorithms on a personal computer. The 3D display of the middle and inner ear structures was demonstrated in detail. Computer-assisted measurements, many of which could not be easily measured in vivo, of the reconstructed structures provided accurate anatomic details that improved the surgeon’s understanding of spatial relationships. A 3D reconstruction of temporal bone CT might be useful for education and increasing understanding of the anatomical structures of the temporal bone. However, it will be necessary to confirm the correlation between the 3D reconstructed images and histological sections through a validation study.


2000 ◽  
Vol 122 (5) ◽  
pp. 528-533 ◽  
Author(s):  
C. P. Neu ◽  
R. D. McGovern ◽  
J. J. Crisco

The use of registration techniques to determine motion transformations noninvasively has become more widespread with the increased availability of the necessary software. In this study, three surface registration techniques were used to generate carpal bone kinematic results from a single cadaveric wrist specimen. Surface contours were extracted from specimen computed tomography volume images of the forearm, carpal, and metacarpal bones in four arbitrary positions. Kinematic results from each of three registration techniques were compared with results derived from multiple spherical markers fixed to the specimen. Kinematic accuracy was found to depend on the registration method and bone size and shape. In general, rotation errors of the capitate and scaphoid were less than 0.5 deg for all three techniques. Rotation errors for the other bones were generally less than 2 deg, although error for the trapezoid was greater than 2 deg in one technique. Translation errors of the bones were generally less than 1 mm, although errors of the trapezoid and trapezium were greater than 1 mm for two techniques. Tradeoffs existed in each registration method between image processing time and overall kinematic accuracy. Markerless bone registration (MBR) can provide accurate measurements of carpal kinematics and can be used to study the noninvasive, three-dimensional in vivo kinematics of the wrist and other skeletal joints. [S0148-0731(00)01105-5]


2021 ◽  
Vol 10 (18) ◽  
pp. 4183
Author(s):  
Yen-Ting Han ◽  
Wei-Chun Lin ◽  
Fang-Yu Fan ◽  
Chih-Long Chen ◽  
Chia-Cheng Lin ◽  
...  

This study compared the accuracy of static computer-assisted implant surgery (sCAIS) planned through dental surface image registration and fiducial marker registration. Stone models of 30 patients were converted into digital dental casts by using a desktop scanner. Cone-beam computed tomography (CBCT) was performed and superimposed to the digital dental casts with two methods: matching the dental surface images or matching the fiducial markers on a stereolithographic radiographic template. Following the implant planning, stereolithographic surgical guides were fabricated, and 56 fully guided implants were inserted by the same doctor. Deviations between planned and inserted implants were measured and compared using postoperative CBCT images. After adjustment for other potential influencing factors, compared with the fiducial marker registration group, significantly larger mean lateral deviations were noted in the dental surface registration group at both the implant platform and apex (p = 0.0188 and 0.0371, respectively). However, the mean lateral deviations for the dental surface registration (0.83 ± 0.51 mm at implant platform and 1.24 ± 0.68 mm at implant apex) were comparable to the literature. In conclusion, our findings indicate that although sCAIS planned using dental surface image registration was not statistically as accurate as that using fiducial marker registration, its accuracy was satisfactory for clinical use.


2003 ◽  
Vol 33 (2) ◽  
pp. 104-109 ◽  
Author(s):  
Rosalia Csutak ◽  
Lukas Unterassinger ◽  
Claudia Rohrmeister ◽  
Manfred Weninger ◽  
Klara A. Vergesslich

2012 ◽  
Vol 443-444 ◽  
pp. 537-541
Author(s):  
Xiao Peng Wang ◽  
Yuan Zhi Cheng ◽  
Ming Ming Zhao ◽  
Xiao Hua Ding ◽  
Jing Bai

We describe a technique for the registration of three dimensional (3D) knee bone surface points from MR image data sets. This technique is grounded on a mathematical theory – Lipschitz optimization. Based on this theory, we propose a global search algorithm that simultaneously determines the transformation and point correspondences. Compared with the other three registration approaches (ICP, EM-ICP, and genetic algorithms), the new proposed method achieved the highest registration accuracy on animal data.


Author(s):  
D. Reis ◽  
B. Vian ◽  
J. C. Roland

Wall morphogenesis in higher plants is a problem still open to controversy. Until now the possibility of a transmembrane control and the involvement of microtubules were mostly envisaged. Self-assembly processes have been observed in the case of walls of Chlamydomonas and bacteria. Spontaneous gelling interactions between xanthan and galactomannan from Ceratonia have been analyzed very recently. The present work provides indications that some processes of spontaneous aggregation could occur in higher plants during the formation and expansion of cell wall.Observations were performed on hypocotyl of mung bean (Phaseolus aureus) for which growth characteristics and wall composition have been previously defined.In situ, the walls of actively growing cells (primary walls) show an ordered three-dimensional organization (fig. 1). The wall is typically polylamellate with multifibrillar layers alternately transverse and longitudinal. Between these layers intermediate strata exist in which the orientation of microfibrils progressively rotates. Thus a progressive change in the morphogenetic activity occurs.


Author(s):  
A.M. Jones ◽  
A. Max Fiskin

If the tilt of a specimen can be varied either by the strategy of observing identical particles orientated randomly or by use of a eucentric goniometer stage, three dimensional reconstruction procedures are available (l). If the specimens, such as small protein aggregates, lack periodicity, direct space methods compete favorably in ease of implementation with reconstruction by the Fourier (transform) space approach (2). Regardless of method, reconstruction is possible because useful specimen thicknesses are always much less than the depth of field in an electron microscope. Thus electron images record the amount of stain in columns of the object normal to the recording plates. For single particles, practical considerations dictate that the specimen be tilted precisely about a single axis. In so doing a reconstructed image is achieved serially from two-dimensional sections which in turn are generated by a series of back-to-front lines of projection data.


Author(s):  
Greg V. Martin ◽  
Ann L. Hubbard

The microtubule (MT) cytoskeleton is necessary for many of the polarized functions of hepatocytes. Among the functions dependent on the MT-based cytoskeleton are polarized secretion of proteins, delivery of endocytosed material to lysosomes, and transcytosis of integral plasma membrane (PM) proteins. Although microtubules have been shown to be crucial to the establishment and maintenance of functional and structural polarization in the hepatocyte, little is known about the architecture of the hepatocyte MT cytoskeleton in vivo, particularly with regard to its relationship to PM domains and membranous organelles. Using an in situ extraction technique that preserves both microtubules and cellular membranes, we have developed a protocol for immunofluorescent co-localization of cytoskeletal elements and integral membrane proteins within 20 µm cryosections of fixed rat liver. Computer-aided 3D reconstruction of multi-spectral confocal microscope images was used to visualize the spatial relationships among the MT cytoskeleton, PM domains and intracellular organelles.


Sign in / Sign up

Export Citation Format

Share Document