Kinematic Accuracy of Three Surface Registration Methods in a Three-Dimensional Wrist Bone Study

2000 ◽  
Vol 122 (5) ◽  
pp. 528-533 ◽  
Author(s):  
C. P. Neu ◽  
R. D. McGovern ◽  
J. J. Crisco

The use of registration techniques to determine motion transformations noninvasively has become more widespread with the increased availability of the necessary software. In this study, three surface registration techniques were used to generate carpal bone kinematic results from a single cadaveric wrist specimen. Surface contours were extracted from specimen computed tomography volume images of the forearm, carpal, and metacarpal bones in four arbitrary positions. Kinematic results from each of three registration techniques were compared with results derived from multiple spherical markers fixed to the specimen. Kinematic accuracy was found to depend on the registration method and bone size and shape. In general, rotation errors of the capitate and scaphoid were less than 0.5 deg for all three techniques. Rotation errors for the other bones were generally less than 2 deg, although error for the trapezoid was greater than 2 deg in one technique. Translation errors of the bones were generally less than 1 mm, although errors of the trapezoid and trapezium were greater than 1 mm for two techniques. Tradeoffs existed in each registration method between image processing time and overall kinematic accuracy. Markerless bone registration (MBR) can provide accurate measurements of carpal kinematics and can be used to study the noninvasive, three-dimensional in vivo kinematics of the wrist and other skeletal joints. [S0148-0731(00)01105-5]

2018 ◽  
Vol 140 (4) ◽  
Author(s):  
Gordon M. Best ◽  
Michelle L. Zec ◽  
David R. Pichora ◽  
Robin N. Kamal ◽  
Michael J. Rainbow

Previous two-dimensional (2D) studies have shown that there is a spectrum of carpal mechanics that varies between row-type motion and column-type motion as a function of wrist laxity. More recent three-dimensional (3D) studies have suggested instead that carpal bone motion is consistent across individuals. The purpose of this study was to use 3D methods to determine whether carpal kinematics differ between stiffer wrists and wrists with higher laxity. Wrist laxity was quantified using a goniometer in ten subjects by measuring passive wrist flexion–extension (FE) range of motion (ROM). In vivo kinematics of subjects' scaphoid and lunate with respect to the radius were computed from computed tomography (CT) volume images in wrist radial and ulnar deviation positions. Scaphoid and lunate motion was defined as “column-type” if the bones flexed and extended during wrist radial–ulnar deviation (RUD), and “row-type” if the bones radial–ulnar deviated during wrist RUD. We found that through wrist RUD, the scaphoid primarily flexed and extended, but the scaphoids of subjects with decreased laxity had a larger component of RUD (R2 = 0.48, P < 0.05). We also determined that the posture of the scaphoid in the neutral wrist position predicts wrist radial deviation (RD) ROM (R2 = 0.46, P < 0.05). These results suggest that ligament laxity plays a role in affecting carpal bone motion of the proximal row throughout radial and ulnar deviation motions; however, other factors such as bone position may also affect motion. By developing a better understanding of normal carpal kinematics and how they are affected, this will help physicians provide patient-specific approaches to different wrist pathologies.


2009 ◽  
Vol 30 (05) ◽  
pp. 432-438 ◽  
Author(s):  
Akira Goto ◽  
Hisao Moritomo ◽  
Tomonobu Itohara ◽  
Tetsu Watanabe ◽  
Kazuomi Sugamoto

2002 ◽  
Vol 27 (2) ◽  
pp. 233-242 ◽  
Author(s):  
Douglas C. Moore ◽  
Kathleen A. Hogan ◽  
Joseph J. Crisco ◽  
Edward Akelman ◽  
Manuel F. DaSilva ◽  
...  

2002 ◽  
Vol 17 (7) ◽  
pp. 506-514 ◽  
Author(s):  
T.M Moojen ◽  
J.G Snel ◽  
M.J.P.F Ritt ◽  
J.M.G Kauer ◽  
H.W Venema ◽  
...  

1998 ◽  
Vol 14 (3) ◽  
pp. 312-326 ◽  
Author(s):  
Timothy J. Koh ◽  
Mark D. Grabiner ◽  
John J. Brems

Shoulder kinematics, including scapular rotation relative to the trunk and humeral rotation relative to the scapula, were examined during humeral elevation in three vertical planes via video analysis of intracortical pins. Helical axis parameters provided an easily interpretable description of shoulder motion not subject to the limitations associated with Cardan/Euler angles. Between 30 and 150° of elevation in each plane, the scapula rotated almost solely about an axis perpendicular to the scapula. Additional scapular rotation appeared to support the notion that the scapula moves “toward” the plane of elevation. Humeral rotation took place mainly in the plane of the scapula independent of the plane of elevation. Many parameters of shoulder complex kinematics were quite similar across all planes of elevation, suggesting a consistent movement pattern with subtle differences associated with the plane of elevation.


2016 ◽  
Vol 138 (9) ◽  
Author(s):  
Koren E. Roach ◽  
Bibo Wang ◽  
Ashley L. Kapron ◽  
Niccolo M. Fiorentino ◽  
Charles L. Saltzman ◽  
...  

Measurements of joint kinematics are essential to understand the pathomechanics of ankle disease and the effects of treatment. Traditional motion capture techniques do not provide measurements of independent tibiotalar and subtalar joint motion. In this study, high-speed dual fluoroscopy images of ten asymptomatic adults were acquired during treadmill walking at 0.5 m/s and 1.0 m/s and a single-leg, balanced heel-rise. Three-dimensional (3D) CT models of each bone and dual fluoroscopy images were used to quantify in vivo kinematics for the tibiotalar and subtalar joints. Dynamic tibiotalar and subtalar mean joint angles often exhibited opposing trends during captured stance. During both speeds of walking, the tibiotalar joint had significantly greater dorsi/plantarflexion (D/P) angular ROM than the subtalar joint while the subtalar joint demonstrated greater inversion/eversion (In/Ev) and internal/external rotation (IR/ER) than the tibiotalar joint. During balanced heel-rise, only D/P and In/Ev were significantly different between the tibiotalar and subtalar joints. Translational ROM in the anterior/posterior (AP) direction was significantly greater in the subtalar than the tibiotalar joint during walking at 0.5 m/s. Overall, our results support the long-held belief that the tibiotalar joint is primarily responsible for D/P, while the subtalar joint facilitates In/Ev and IR/ER. However, the subtalar joint provided considerable D/P rotation, and the tibiotalar joint rotated about all three axes, which, along with translational motion, suggests that each joint undergoes complex, 3D motion.


2007 ◽  
Vol 27 (10) ◽  
pp. 1742-1755 ◽  
Author(s):  
Albertine Dubois ◽  
Julien Dauguet ◽  
Anne-Sophie Herard ◽  
Laurent Besret ◽  
Edouard Duchesnay ◽  
...  

Besides the newly developed positron emission tomography scanners (microPET) dedicated to the in vivo functional study of small animals, autoradiography remains the reference technique widely used for functional brain imaging and the gold standard for the validation of in vivo results. The analysis of autoradiographic data is classically achieved in two dimensions (2D) using a section-by-section approach, is often limited to few sections and the delineation of the regions of interest to be analysed is directly performed on autoradiographic sections. In addition, such approach of analysis does not accommodate the possible anatomical shifts linked to dissymmetry associated with the sectioning process. This classic analysis is time-consuming, operator-dependent and can therefore lead to non-objective and non-reproducible results. In this paper, we have developed an automated and generic toolbox for processing of autoradiographic and corresponding histological rat brain sections based on a three-step approach, which involves: (1) an optimized digitization dealing with hundreds of autoradiographic and histological sections; (2) a robust reconstruction of the volumes based on a reliable registration method; and (3) an original 3D-geometry-based approach to analysis of anatomical and functional post-mortem data. The integration of the toolbox under a unified environment (in-house software BrainVISA, http://brainvisa.info ) with a graphic interface enabled a robust and operator-independent exploitation of the overall anatomical and functional information. We illustrated the substantial qualitative and quantitative benefits obtained by applying our methodology to an activation study (rats, n = 5, under unilateral visual stimulation).


Sign in / Sign up

Export Citation Format

Share Document