X-ray determination of the mean Debye-Waller factors, amplitudes of vibrations and the Debye temperatures of CdO, PbS and MnS

Pramana ◽  
1978 ◽  
Vol 10 (4) ◽  
pp. 357-360 ◽  
Author(s):  
K G Subhadra ◽  
D B Sirdeshmukh
Keyword(s):  
X Ray ◽  
1997 ◽  
Vol 30 (4) ◽  
pp. 427-430 ◽  
Author(s):  
F. Sánchez-Bajo ◽  
F. L. Cumbrera

A modified application of the variance method, using the pseudo-Voigt function as a good approximation to the X-ray diffraction profiles, is proposed in order to obtain microstructural quantities such as the mean crystallite size and root-mean-square (r.m.s.) strain. Whereas the variance method in its original form is applicable only to well separated reflections, this technique can be employed in the cases where there is line-profile overlap. Determination of the mean crystallite size and r.m.s. strain for several crystallographic directions in a nanocrystalline cubic sample of 9-YSZ (yttria-stabilized zirconia) has been performed by means of this procedure.


Pramana ◽  
1992 ◽  
Vol 38 (6) ◽  
pp. 681-683 ◽  
Author(s):  
K G Subhadra ◽  
B Raghavendra Rao ◽  
D B Sirdeshmukh
Keyword(s):  
X Ray ◽  

1987 ◽  
Vol 70 (4) ◽  
pp. 664-667
Author(s):  
Tee-Siaw Koh

Abstract Fifty-one laboratories from 14 countries participated in a survey on the determination of selenium (Se) in 8 bovine blood samples with Se concentrations ranging from 0.2 μmol/L (0.016 μg/mL) to 14 μmol/L (1.1 μg/mL). The methods used (and the percentage of participants using each method) were fiuorometry (61), hydride-generation atomic absorption spectrophotometry (AAS) (23), graphitefurnace AAS (6), gas chromatography (4), neutron activation analysis (4), and X-ray fiuorometry (2). There was little difference in the mean Se results obtained by fiuorometry or hydride-generation AAS (P > 0.05). Mean intralaboratory coefficients of variation (CVs) from known replicates ranged from 4 to 14% for all samples. Interlaboratory CVs were related to blood Se concentration and increased to 55% at Se levels below 0.4 μmol/L (0.032 μg/mL). Laboratories that used quality control (QC) schemes had lower interlaboratory CVs than those that did not, but the advantage began to diminish at blood Se concentration below 0.4 μmol/L (0.032 μg/mL). The high interlaboratory CVs, coupled with the false assurance from the low intralaboratory CVs and the ineffectiveness of the QC schemes at blood Se concentrations below 0.4 μmol/L (0.032 μg/mL), are of concern in diagnosis of marginal Se deficiency in livestock where the concentrations of interest are in the range 0.15-0.5 μmol/L (0.012-0.039 μg/mL).


1999 ◽  
Vol 34 (2) ◽  
pp. 305-316 ◽  
Author(s):  
E.H. Bakraji ◽  
J. Karajo

Abstract Total reflection X-ray fluorescence spectrometry and chemical preconcentration have been applied for multi-elemental analysis of Damascus drinking water. Water was taken directly from taps of several city sectors and analyzed for the following trace elements: Ti, V, Cr, Fe, Co, Ni, Cu, Zn, Se and Pb. The detection limits were found to be in the range of 0.1 to 0.4 µg/L. The mean levels of trace elements in the Damascus drinking water were below the World Health Organization drinking water quality guidelines.