Preparation and properties of sensing membrane for fiber optic oxygen sensor

2002 ◽  
Vol 17 (2) ◽  
pp. 51-53 ◽  
Author(s):  
Jiang De-sheng ◽  
Chen Xing ◽  
Liu Er ◽  
Huang Jun
2004 ◽  
Vol 19 (1) ◽  
pp. 19-22
Author(s):  
Huang Jun ◽  
Han Yun ◽  
Zhang Tian-hua ◽  
Jiang De-sheng ◽  
Yue Fang-yu

2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Zizheng Yue ◽  
Wenlin Feng

Abstract In this work, a fiber-optic fluoride-ion-detection Michelson interferometer based on the thin-core fiber (TCF) and no-core fiber (NCF) coated with α-Fe2O3/ZrO2 sensing film is proposed and presented. The single-mode fiber (SMF) is spliced with the TCF and NCF in turn, and a waist-enlarged taper is spliced between them. Then, a silver film is plated on the end face of NCF to enhance the reflection. After the absorption of fluoride ion by the sensing film, the effective refractive index (RI) of the coated cladding will change, which leads to the regular red shift of the interference dip with the increasing fluoride-ion concentration. Thus, the fluoride-ion concentrations can be determined according to the corresponding dip wavelength shifts. The results show that the sensor has an excellent linear response (R 2 = 0.995) with good sensitivity (8.970 nm/ppm) when the fluoride-ion concentration is in the range of 0–1.5 ppm. The response time is about 15 s. The sensor has the advantage of good selectivity, good temperature and pH stabilities, and can be applied to detect fluoride ion effectively.


2008 ◽  
Vol 161 (2) ◽  
pp. 160-166 ◽  
Author(s):  
Jinjun Jiang ◽  
Lei Gao ◽  
Wei Zhong ◽  
Shen Meng ◽  
Ben Yong ◽  
...  
Keyword(s):  

2016 ◽  
Vol 2 (5) ◽  
pp. 057001 ◽  
Author(s):  
Jianbin Liu ◽  
Chengcheng Wang ◽  
Yingxin Zeng ◽  
Chuping Yang ◽  
Hai Li ◽  
...  

1998 ◽  
Vol 10 (3) ◽  
pp. 278-282
Author(s):  
Eiji Toba ◽  
◽  
Masahiro Ichikawa ◽  
Junji Kazama ◽  
Toyonori Nishimatsu ◽  
...  

This paper describes a fiber-optic oxygen sensor using fluorescence and its application to clinical examinations. The quenching ratio of fluorescence is proportional to oxygen partial pressure by Stern-Volmer's formula in which oxygen concentration is estimated from measured emission intensity. We fabricated a microscopic luminous probe using a Solvent Green 5 doped plastic optical fiber coupler. The probe was studied as an oxygen sensor in visible light. We also clarified sensor characteristics.


Author(s):  
Wei Yubin ◽  
Zhao Weisong ◽  
Hu Jie ◽  
Zhang Tingting ◽  
Liu Tongyu
Keyword(s):  

1994 ◽  
Author(s):  
Brian D. MacCraith ◽  
Gerard O'Keeffe ◽  
Aisling K. McEvoy ◽  
Colette M. McDonagh
Keyword(s):  

Sign in / Sign up

Export Citation Format