Radiological findings in gunshot wounds caused by hunting ammunition. An experimental study

1996 ◽  
Vol 108 (4) ◽  
pp. 201-205 ◽  
Author(s):  
Christian Schyma ◽  
Petra Placidi ◽  
Hans H. Schild
2020 ◽  
Vol 148 (5-6) ◽  
pp. 350-356
Author(s):  
Anisa Gradascevic ◽  
Ivan Soldatovic ◽  
Anes Joguncic ◽  
Miroslav Milosevic ◽  
Nermin Sarajlic

Introduction/Objective. Gunshot residue (GSR) on the skin of a victim are important evidence, with far better precision, for reconstructive questions in the forensic investigation of cases involving gunshot wounds. The aim of this experimental study was to analyze if there was any significant difference in macroscopic characteristics of wounds that were caused with different types of weapons from three different distances. Methods. This study was conducted at the Department of Ballistic and Mechanoscopic Expertise, Federal Police Directorate. Experiments were done on pigskin and 55 samples were made. Shooting was conducted using a system for safe firing. Samples of the pigskin were shot by firing projectiles from four different weapons and from three different distances, (contact wound, five centimetres and 10 centimetres). Results. At the contact range, wounds caused by automatic rifle had horizontal, vertical diameters larger than those made by pistols. Diameters on the wounds that were caused with different pistols, were similar. At the range of five centimetres, the narrowest part of contusion ring significantly differs even through pistol wounds. Diameters at the range of 10 centimetres are in favor of these results. Gunpowder residue scattering area was statistically different depending of type of weapon (p = 0.004). Conclusion. Wound diameters and surface area are useful for differentiation between pistol and rifle caused wounds. It is unsecure method for determination of pistol caliber or fire range. GSR have much greater potential for future analyses, but even GSR cannot be used to determine pistol caliber.


2013 ◽  
Vol 3 (3) ◽  
pp. 232-237 ◽  
Author(s):  
Anisa Gradaščević ◽  
Emina Resić ◽  
Nermin Sarajlić ◽  
Bruno Franjić ◽  
Arif Salkić ◽  
...  

Introduction: The aim of the study was determining the type of weapon and shooting distance depending on chemical analysis of inorganic gunshot residue from the skin gunshot wounds in experimental animals (pigs).Methods: Experimental study was conducted in order to determine components and their percentage in gunshot residue (GSR). In 60 samples, pig skin was shot by fi ring projectiles from four different weapons and from three different distances (contact wound and near contact wound from 5 cm and 10 cm). The methodology included determining the presence of inorganic material: antimony, barium, lead, nickel, zinc and copper in the skin and subcutaneous tissue using atomic absorption spectrophotometry (AAS).Results: Formula for determining weapon type was provided cutt-off points for different weapons, with 78.6% of original grouped cases being correctly classifi ed. Formula for determining weapon type was provided cutt-off points for different distances, with 58.9% of original grouped cases being correctly classified, which was slightly less reliable compared to weapon type discrimination analysis.Conclusion: The presented study showed that chemical analysis of GSR in entrance wound with AAS could be useful in determining the type of weapon, as well as the shooting distance, i.e. in our study, determiningwhether the wound is contact or near contact. This could be particularly useful in postmortally putrefi ed or charred bodies with gunshot wounds.


Author(s):  
Norio Baba ◽  
Norihiko Ichise ◽  
Syunya Watanabe

The tilted beam illumination method is used to improve the resolution comparing with the axial illumination mode. Using this advantage, a restoration method of several tilted beam images covering the full azimuthal range was proposed by Saxton, and experimentally examined. To make this technique more reliable it seems that some practical problems still remain. In this report the restoration was attempted and the problems were considered. In our study, four problems were pointed out for the experiment of the restoration. (1) Accurate beam tilt adjustment to fit the incident beam to the coma-free axis for the symmetrical beam tilting over the full azimuthal range. (2) Accurate measurements of the optical parameters which are necessary to design the restoration filter. Even if the spherical aberration coefficient Cs is known with accuracy and the axial astigmatism is sufficiently compensated, at least the defocus value must be measured. (3) Accurate alignment of the tilt-azimuth series images.


1962 ◽  
Vol 5 (4) ◽  
pp. 387-394 ◽  
Author(s):  
Bruce Quarrington ◽  
Jerome Conway ◽  
Nathan Siegel
Keyword(s):  

1974 ◽  
Vol 126 (2) ◽  
pp. 243-248
Author(s):  
A WAKABAYASHI ◽  
T KUBO ◽  
K CHARNEY ◽  
Y NAKAMURA ◽  
J CONNOLLY

Sign in / Sign up

Export Citation Format

Share Document