CELIAS - Charge, Element and Isotope Analysis System for SOHO

Solar Physics ◽  
1995 ◽  
Vol 162 (1-2) ◽  
pp. 441-481 ◽  
Author(s):  
D. Hovestadt ◽  
M. Hilchenbach ◽  
A. B�rgi ◽  
B. Klecker ◽  
P. Laeverenz ◽  
...  
1995 ◽  
pp. 441-481 ◽  
Author(s):  
D. Hovestadt ◽  
M. Hilchenbach ◽  
A. Bürgi ◽  
B. Klecker ◽  
P. Laeverenz ◽  
...  

2013 ◽  
Vol 30 (9) ◽  
pp. 2095-2107 ◽  
Author(s):  
Brett F. Thornton ◽  
Axel Horst ◽  
Daniel Carrizo ◽  
Henry Holmstrand ◽  
Per Andersson ◽  
...  

Abstract A system was developed for collecting from the ambient atmosphere the methyl halides CH3Cl and CH3Br in quantities sufficient for chlorine and bromine isotope analysis. The construction and operation of the novel cryogenic collection system (cryosampler) and sample purification system developed for this task are described. This study demonstrates the capability of the cryosampler by quantifying the CH3Cl and CH3Br collected from atmospheric samples and the nonfractionating bromine isotope fingerprint of CH3Br from synthetic air samples of controlled composition. An optimized cryosampler operation time of 4 h at a flow rate of 15 L min−1 is applied to yield the nearly 40 ng required for subsequent δ81Br-CH3Br analyses. The sample purification system is designed around a packed column gas chromatography–quadropole–mass spectrometry (GCqMS) system with three additional cryotraps and backflushing capacity. The system's suitability was tested by observing both the mass recovery and the lack of Δ81Br isotope fractionation induced during sample purification under varying flow rates and loading scenarios. To demonstrate that the entire system samples and dependably delivers CH3Br to the isotope analysis system without inducing isotope fractionation, diluted synthetic air mixtures prepared from standard gases were processed through the entire system, yielding a Δ81Br-CH3Br of +0.03‰ ± 0.10‰ relative to their starting composition. Finally, the combined cryosampler–purification and analysis system was applied to demonstrate the first-ever δ81Br-CH3Br in the ambient atmosphere with two samples collected in the autumn of 2011, yielding −0.08‰ ± 0.43‰ and +1.75‰ ± 0.13‰ versus standard mean ocean bromide for samples collected at a suburban Stockholm, Sweden, site.


Author(s):  
D. Hovestadt ◽  
P. Bochsler ◽  
H. Grünwaldt ◽  
F. Gliem ◽  
M. Hilchenbach ◽  
...  

Author(s):  
S.F. Stinson ◽  
J.C. Lilga ◽  
M.B. Sporn

Increased nuclear size, resulting in an increase in the relative proportion of nuclear to cytoplasmic sizes, is an important morphologic criterion for the evaluation of neoplastic and pre-neoplastic cells. This paper describes investigations into the suitability of automated image analysis for quantitating changes in nuclear and cytoplasmic cross-sectional areas in exfoliated cells from tracheas treated with carcinogen.Neoplastic and pre-neoplastic lesions were induced in the tracheas of Syrian hamsters with the carcinogen N-methyl-N-nitrosourea. Cytology samples were collected intra-tracheally with a specially designed catheter (1) and stained by a modified Papanicolaou technique. Three cytology specimens were selected from animals with normal tracheas, 3 from animals with dysplastic changes, and 3 from animals with epidermoid carcinoma. One hundred randomly selected cells on each slide were analyzed with a Bausch and Lomb Pattern Analysis System automated image analyzer.


Author(s):  
A. V. Crewe ◽  
M. Ohtsuki

We have assembled an image processing system for use with our high resolution STEM for the particular purpose of working with low dose images of biological specimens. The system is quite flexible, however, and can be used for a wide variety of images.The original images are stored on magnetic tape at the microscope using the digitized signals from the detectors. For low dose imaging, these are “first scan” exposures using an automatic montage system. One Nova minicomputer and one tape drive are dedicated to this task.The principal component of the image analysis system is a Lexidata 3400 frame store memory. This memory is arranged in a 640 x 512 x 16 bit configuration. Images are displayed simultaneously on two high resolution monitors, one color and one black and white. Interaction with the memory is obtained using a Nova 4 (32K) computer and a trackball and switch unit provided by Lexidata.The language used is BASIC and uses a variety of assembly language Calls, some provided by Lexidata, but the majority written by students (D. Kopf and N. Townes).


Author(s):  
D.S. DeMiglio

Much progress has been made in recent years towards the development of closed-loop foundry sand reclamation systems. However, virtually all work to date has determined the effectiveness of these systems to remove surface clay and metal oxide scales by a qualitative inspection of a representative sampling of sand particles. In this investigation, particles from a series of foundry sands were sized and chemically classified by a Lemont image analysis system (which was interfaced with an SEM and an X-ray energy dispersive spectrometer) in order to statistically document the effectiveness of a reclamation system developed by The Pangborn Company - a subsidiary of SOHIO.The following samples were submitted: unreclaimed sand; calcined sand; calcined & mechanically scrubbed sand and unused sand. Prior to analysis, each sample was sprinkled onto a carbon mount and coated with an evaporated film of carbon. A backscattered electron photomicrograph of a field of scale-covered particles is shown in Figure 1. Due to a large atomic number difference between sand particles and the carbon mount, the backscattered electron signal was used for image analysis since it had a uniform contrast over the shape of each particle.


Author(s):  
W. O. Saxton

Recent commercial microscopes with internal microprocessor control of all major functions have already demonstrated some of the benefits anticipated from such systems, such as continuous magnification, rotation-free diffraction and magnification, automatic recording of mutually registered focal series, and fewer control knobs. Complete automation of the focusing, stigmating and alignment of a high resolution microscope, allowing focal series to be recorded at preselected focus values as well, is still imminent rather than accomplished, however; some kind of image pick-up and analysis system, fed with the electron image via a TV camera, is clearly essential for this, but several alternative systems and algorithms are still being explored. This paper reviews the options critically in turn, and stresses the need to consider alignment and focusing at an early stage, and not merely as an optional extension to a basic proposal.


1974 ◽  
Vol 38 (12) ◽  
pp. 691-696
Author(s):  
GL Olde ◽  
CP Cole ◽  
JW Wittrock

Sign in / Sign up

Export Citation Format

Share Document