Calculation of the signal time-profile in transient CARS experiments

1991 ◽  
Vol 52 (2) ◽  
pp. 132-137 ◽  
Author(s):  
R. Torre ◽  
R. Righini ◽  
P. Foggi ◽  
L. Angeloni
Keyword(s):  
1986 ◽  
Vol 51 (8) ◽  
pp. 1795-1801
Author(s):  
Hana Hájková ◽  
Zdeněk Pavlíček ◽  
Vítěz Kalous

The time profile of changes in the oxygen saturation curves of human hemoglobin in the presence of benzene was investigated. The partial oxygen pressure p50, necessary for a half saturation, decreases during the first 3.5 h of interaction of hemoglobin with benzene and did not change afterwards. The character of changes in Hill's coefficient was similar. The oxygen saturation was modeled both for hemoglobin alone and, using MWC as a model of allosteric interaction, also for hemoglobin and benzene in a computer.


2021 ◽  
Vol 156 ◽  
pp. 107660
Author(s):  
James C. Peyton Jones ◽  
Saeed Shayestehmanesh

2021 ◽  
Vol 10 (4) ◽  
pp. 589
Author(s):  
Mariusz G. Fleszar ◽  
Paulina Fortuna ◽  
Marek Zawadzki ◽  
Paweł Hodurek ◽  
Iwona Bednarz-Misa ◽  
...  

Excessive endocrine response to trauma negatively affects patients’ well-being. Cortisol dynamics following robot-assisted colorectal surgery are unknown. We aimed at determining the impact of cancer pathology and surgery-related factors on baseline cortisol levels and analyzed its time-profile in colorectal cancer patients undergoing open or robot-assisted surgery. Cortisol levels were measured using liquid chromatography quadrupole time-of-flight mass spectrometry. Baseline cortisol was not associated with any patient- or disease-related factors. Post-surgery cortisol increased by 36% at 8 h and returned to baseline on postoperative day three. The cortisol time profile was significantly affected by surgery type, estimated blood loss, and length of surgery. Baseline-adjusted cortisol increase was greater in females at hour 8 and in both females and patients from open surgery group at hour 24. Solely in the open surgery group, cortisol dynamics paralleled changes in interleukin (IL)-1β, IL-10, IL-1ra, IL-7, IL-8 and tumor necrosis factor (TNF)-α but did not correlate with changes in IL-6 or interferon (IFN)-γ at any time-point. Cortisol co-examined with C-reactive protein was predictive of surgical site infections (SSI) with high accuracy. In conclusion, patient’s sex and surgery invasiveness affect cortisol dynamics. Surgery-induced elevation can be reduced by minimally invasive robot-assisted procedures. Cortisol and C-reactive protein as SSI biomarkers might be of value in the evaluation of safety of early discharge of patients.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4347
Author(s):  
Boyun Lyu ◽  
Yu Hua ◽  
Jiangbin Yuan ◽  
Shifeng Li

The Enhanced Loran (eLoran) system is valued for its important role in the positioning, navigation, and timing fields; however, with its current modulation methods, low data rate restricts its development. Ultra narrow band (UNB) modulation is a modulation method with extremely high spectrum utilization. If UNB modulation can be applied to the eLoran system, it will be very helpful. The extended binary phase shift keying modulation in UNB modulation is selected for a detailed study, parameters and application model are designed according to its unique characteristics of signal time and frequency domains, and it is verified through simulation that the application of this modulation not only meets the design constraints of the eLoran system but also does not affect the reception of the respective signals of both parties. Several feasible schemes are compared, analyzed, and selected. Studies have revealed that application of UNB modulation in the eLoran system is feasible, and it will increase the data rate of the system by dozens of times.


Author(s):  
Dimitra Flouri ◽  
Daniel Lesnic ◽  
Constantina Chrysochou ◽  
Jehill Parikh ◽  
Peter Thelwall ◽  
...  

Abstract Introduction Model-driven registration (MDR) is a general approach to remove patient motion in quantitative imaging. In this study, we investigate whether MDR can effectively correct the motion in free-breathing MR renography (MRR). Materials and methods MDR was generalised to linear tracer-kinetic models and implemented using 2D or 3D free-form deformations (FFD) with multi-resolution and gradient descent optimization. MDR was evaluated using a kidney-mimicking digital reference object (DRO) and free-breathing patient data acquired at high temporal resolution in multi-slice 2D (5 patients) and 3D acquisitions (8 patients). Registration accuracy was assessed using comparison to ground truth DRO, calculating the Hausdorff distance (HD) between ground truth masks with segmentations and visual evaluation of dynamic images, signal-time courses and parametric maps (all data). Results DRO data showed that the bias and precision of parameter maps after MDR are indistinguishable from motion-free data. MDR led to reduction in HD (HDunregistered = 9.98 ± 9.76, HDregistered = 1.63 ± 0.49). Visual inspection showed that MDR effectively removed motion effects in the dynamic data, leading to a clear improvement in anatomical delineation on parametric maps and a reduction in motion-induced oscillations on signal-time courses. Discussion MDR provides effective motion correction of MRR in synthetic and patient data. Future work is needed to compare the performance against other more established methods.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Blai Casals ◽  
Karin A. Dahmen ◽  
Boyuan Gou ◽  
Spencer Rooke ◽  
Ekhard K. H. Salje

AbstractAcoustic emission (AE) measurements of avalanches in different systems, such as domain movements in ferroics or the collapse of voids in porous materials, cannot be compared with model predictions without a detailed analysis of the AE process. In particular, most AE experiments scale the avalanche energy E, maximum amplitude Amax and duration D as E ~ Amaxx and Amax ~ Dχ with x = 2 and a poorly defined power law distribution for the duration. In contrast, simple mean field theory (MFT) predicts that x = 3 and χ = 2. The disagreement is due to details of the AE measurements: the initial acoustic strain signal of an avalanche is modified by the propagation of the acoustic wave, which is then measured by the detector. We demonstrate, by simple model simulations, that typical avalanches follow the observed AE results with x = 2 and ‘half-moon’ shapes for the cross-correlation. Furthermore, the size S of an avalanche does not always scale as the square of the maximum AE avalanche amplitude Amax as predicted by MFT but scales linearly S ~ Amax. We propose that the AE rise time reflects the atomistic avalanche time profile better than the duration of the AE signal.


Sign in / Sign up

Export Citation Format

Share Document