Cleaning Procedures

Cell Therapy ◽  
2009 ◽  
pp. 135-144 ◽  
Author(s):  
A. Gee ◽  
D.L. Lyon
Keyword(s):  
Author(s):  
Vera Yakubson ◽  
Victor Zakharov

This paper deals with the specialized corpora building, specifically academic language corpus in the biotechnology field. Being a part of larger research devoted to creation and usage of specialized parallel corpus, this piece aims to analyze the initial step of corpus building. Our main research question was what procedures we need to implement to the texts before using them to develop the corpus. Analysis of previous research showed the significant quantity of papers devoted to corpora creation, including academic specialized corpora. Different sides of the process were analyzed in these researches, including the types of texts used, the principles of crawling, the recommended length of texts etc. As to the text processing for the needs of corpora creation, only the linguistic annotation issues were examined earlier. At the same time, the preliminary cleaning of texts before their usage in corpora may have significant influence on the corpus quality and its utility for the linguistic research. In this paper, we considered three small corpora derived from the same set of academic texts in the biotechnology field: “raw” corpus without any preliminary cleaning and two corpora with different level of cleaning. Using different Sketch Engine tools, we analyzed these corpora from the position of their future users, predominantly as sources for academic wordlists and specialized multi-word units. The conducted research showed very little difference between two cleaned corpora, meaning that only basic cleaning procedures such as removal of reference lists are can be useful in corpora design. At the same time, we found a significant difference between raw and cleaned corpora and argue that this difference can affect the quality of wordlists and multi-word terms extraction, therefore these cleaning procedures are meaningful. The main limitation of the study is that all texts were taken from the unique source, so the conclusions could be affected by this specific journal’s peculiarities. Therefore, the future work should be the verification of results on different text collections


Radiocarbon ◽  
2021 ◽  
pp. 1-17
Author(s):  
Shawn Pedron ◽  
X Xu ◽  
J C Walker ◽  
J C Ferguson ◽  
R G Jespersen ◽  
...  

ABSTRACT We developed a passive sampler for time-integrated collection and radiocarbon (14C) analysis of soil respiration, a major flux in the global C cycle. It consists of a permanent access well that controls the CO2 uptake rate and an exchangeable molecular sieve CO2 trap. We tested how access well dimensions and environmental conditions affect collected CO2, and optimized cleaning procedures to minimize 14CO2 memory. We also deployed two generations of the sampler in Arctic tundra for up to two years, collecting CO2 over periods of 3 days–2 months, while monitoring soil temperature, volumetric water content, and CO2 concentration. The sampler collects CO2 at a rate proportional to the length of a silicone tubing inlet (7–26 µg CO2-C day-1·m Si-1). With constant sampler dimensions in the field, CO2 recovery is best explained by soil temperature. We retrieved 0.1–5.3 mg C from the 1st and 0.6–13 mg C from the 2nd generation samplers, equivalent to uptake rates of 2–215 (n=17) and 10–247 µg CO2-C day-1 (n=20), respectively. The method blank is 8 ± 6 µg C (mean ± sd, n=8), with a radiocarbon content (fraction modern) ranging from 0.5875–0.6013 (n=2). The sampler enables more continuous investigations of soil C emission sources and is suitable for Arctic environments.


2020 ◽  
Vol 30 (Supplement_5) ◽  
Author(s):  
R Bosco ◽  
S Gambelli ◽  
V Urbano ◽  
G Cevenini ◽  
G Messina

Abstract Background Sanitizing the operating theatres (OT) is important to minimize risk of post-operative infections. Disinfection procedures between one operation and another is less aggressive than final cleaning procedures, at the end of the day. Aim was assessing the difference of contamination: i) between different levels of disinfection; ii) before and after the use of a UVC Device (UVC-D). Methods Between December 2019/February 2020 a cross sectional study was conducted in OT in a real clinical context. 94 Petri dishes (PD) were used in 3 OT. Three different sanitation levels (SL1-3) were compared pre- and post-use of UVC-D: i) No cleaning after surgery (SL1); ii) after in-between cleaning (SL2); iii) after terminal cleaning (SL3). UVC-D was employed for 6 minutes, 3 minutes per bed side. PD were incubated at 36 °C and colony forming unit (CFU) counted at 48h. Descriptive statistic, Wilcoxon and Mann-Whitney tests were performed to assess the contamination levels in total, pre/post use of UVC-D, and between different sanitation levels, respectively. Results In total we had a mean of 3.39 CFU/PD (C.I. 2.05 - 4.74) and a median of 1 CFU/PD (Min. 0 - Max. 39), after UVC-D use we had a mean of 2.20 CFU/PD (C.I. 0.69 - 5.09) and a median of 0 CFU/PD (Min. 0 - Max. 133). The UVC-D led to a significant reduction of CFU (p < 0.001). Without UVC-D we had a significant CFU drop (p < 0.05) between SL1 and SL3. Using UVC-D, we observed significant reductions of contamination (p < 0.05) between SL3 and SL1. Comparing SL1 (median 0) post UVC-D use vs SL2 pre UVC-D use (median 0.5), and SL2 post UVC-D use (median 0) vs SL3 pre UVC-D use (median 1) we had a significant reduction of contamination (p < 0.05). Conclusions UVC-D improved environmental contamination in any of the three sanitation levels. Furthermore, the use of UVC-D alone was better than in-between and terminal cleaning. Although these encouraging results, the cleaning procedures executed by dedicated staff has to be considered. Key messages UVC are efficient to decrease contamination in operating theatres regardless of sanitation levels. The additional use of UVC technology to standard cleaning procedures significantly improves sanitation levels.


Micromachines ◽  
2021 ◽  
Vol 12 (2) ◽  
pp. 209
Author(s):  
Patrick Kiele ◽  
Jan Hergesell ◽  
Melanie Bühler ◽  
Tim Boretius ◽  
Gregg Suaning ◽  
...  

Neural implants provide effective treatment and diagnosis options for diseases where pharmaceutical therapies are missing or ineffective. These active implantable medical devices (AIMDs) are designed to remain implanted and functional over decades. A key factor for achieving reliability and longevity are cleaning procedures used during manufacturing to prevent failures associated with contaminations. The Implantable Devices Group (IDG) at University College London (UCL) pioneered an approach which involved a cocktail of reagents described as “Leslie’s soup”. This process proved to be successful but no extensive evaluation of this method and the cocktail’s ingredients have been reported so far. Our study addressed this gap by a comprehensive analysis of the efficacy of this cleaning method. Surface analysis techniques complemented adhesion strengths methods to identify residues of contaminants like welding flux, solder residues or grease during typical assembly processes. Quantitative data prove the suitability of “Leslie’s soup” for cleaning of ceramic components during active implant assembly when residual ionic contaminations were removed by further treatment with isopropanol and deionised water. Solder and flux contaminations were removed without further mechanical cleaning. The adhesive strength of screen-printed metalisation layers increased from 12.50 ± 3.83 MPa without initial cleaning to 21.71 ± 1.85 MPa. We conclude that cleaning procedures during manufacturing of AIMDs, especially the understanding of applicability and limitations, is of central importance for their reliable and longevity.


LWT ◽  
2019 ◽  
Vol 106 ◽  
pp. 44-49 ◽  
Author(s):  
A.E. Guerrero-Navarro ◽  
A.G. Ríos-Castillo ◽  
C. Ripolles Avila ◽  
A.S. Hascoët ◽  
X. Felipe ◽  
...  
Keyword(s):  

2006 ◽  
Vol 2006 ◽  
pp. 1-5 ◽  
Author(s):  
Romina Belli ◽  
Antonio Miotello ◽  
Paolo Mosaner ◽  
Laura Toniutti ◽  
Marta Bazzanella

In the archaeological field, some specific advantages are recognized to laser cleaning, like, for example, the absence of mechanical contacts with the sample. The cleaning procedures generally involve a multilayer structure (dust, dirty, organic deposits, and, in some cases, consolidant substances). In this work, prehistoric wood samples (found and consolidated in 1970s) have been laser irradiated (KrF excimer laser) in order to restore their original surface aspect. A certain amount of burned matter was also present. Samples came from a fragment of a prehistoric basketry found in the lake dwelling site of Fiavè-Carera, Trento, Italy (1500–1400 BC). It was observed that the laser cleaning effects are strictly dependent on the irradiation parameters (power density and number of pulses). Efficient material removal was possible by using appropriate energy density. Moreover, for lower laser energy density, special structures appeared on the surface of the consolidating substance that we attributed to heating-induced stresses on the consolidant surface.


2005 ◽  
Vol 51 (6-7) ◽  
pp. 181-192 ◽  
Author(s):  
Z. Lewandowski ◽  
H. Beyenal

The goal of this presentation is to identify biofouling mechanisms that cause undesirable effects to the membrane separation processes of flux decline and pressure drop. The underlying assumption of this presentation is that biofouling is unavoidable and that the operator cannot eliminate it entirely. This premise justifies research efforts toward understanding the mechanisms by which biofouling affects the membrane processes, rather than expecting that technology can entirely eliminate membrane biofouling in the near future. An improved understanding of biofouling mechanisms may lead to better membrane design, better membrane modules, and better membrane cleaning procedures.


Sign in / Sign up

Export Citation Format

Share Document