Quantitative Molecular Characterization of Bovine Vitreous and Lens with Non-invasive Dynamic Light Scattering

2001 ◽  
Vol 73 (6) ◽  
pp. 859-866 ◽  
Author(s):  
R.R. Ansari ◽  
K.I. Suh ◽  
S. Dunker ◽  
N. Kitaya ◽  
J. Sebag
2012 ◽  
Vol 87 (4) ◽  
pp. 2376-2380 ◽  
Author(s):  
W.A. de Morais ◽  
M.R. Pereira ◽  
J.L.C. Fonseca

Pharmaceutics ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 586
Author(s):  
Liam Cole ◽  
Diogo Fernandes ◽  
Maryam T. Hussain ◽  
Michael Kaszuba ◽  
John Stenson ◽  
...  

Viruses are increasingly used as vectors for delivery of genetic material for gene therapy and vaccine applications. Recombinant adeno-associated viruses (rAAVs) are a class of viral vector that is being investigated intensively in the development of gene therapies. To develop efficient rAAV therapies produced through controlled and economical manufacturing processes, multiple challenges need to be addressed starting from viral capsid design through identification of optimal process and formulation conditions to comprehensive quality control. Addressing these challenges requires fit-for-purpose analytics for extensive characterization of rAAV samples including measurements of capsid or particle titer, percentage of full rAAV particles, particle size, aggregate formation, thermal stability, genome release, and capsid charge, all of which may impact critical quality attributes of the final product. Importantly, there is a need for rapid analytical solutions not relying on the use of dedicated reagents and costly reference standards. In this study, we evaluate the capabilities of dynamic light scattering, multiangle dynamic light scattering, and SEC–MALS for analyses of rAAV5 samples in a broad range of viral concentrations (titers) at different levels of genome loading, sample heterogeneity, and sample conditions. The study shows that DLS and MADLS® can be used to determine the size of full and empty rAAV5 (27 ± 0.3 and 33 ± 0.4 nm, respectively). A linear range for rAAV5 size and titer determination with MADLS was established to be 4.4 × 1011–8.7 × 1013 cp/mL for the nominally full rAAV5 samples and 3.4 × 1011–7 × 1013 cp/mL for the nominally empty rAAV5 samples with 3–8% and 10–37% CV for the full and empty rAAV5 samples, respectively. The structural stability and viral load release were also inferred from a combination of DLS, SEC–MALS, and DSC. The structural characteristics of the rAAV5 start to change from 40 °C onward, with increasing aggregation observed. With this study, we explored and demonstrated the applicability and value of orthogonal and complementary label-free technologies for enhanced serotype-independent characterization of key properties and stability profiles of rAAV5 samples.


2021 ◽  
Vol 22 (23) ◽  
pp. 12946
Author(s):  
Ksenija Kogej ◽  
Darja Božič ◽  
Borut Kobal ◽  
Maruša Herzog ◽  
Katarina Černe

In parallel to medical treatment of ovarian cancer, methods for the early detection of cancer tumors are being sought. In this contribution, the use of non-invasive static (SLS) and dynamic light scattering (DLS) for the characterization of extracellular nanoparticles (ENPs) in body fluids of advanced serous ovarian cancer (OC) and benign gynecological pathology (BP) patients is demonstrated and critically evaluated. Samples of plasma and ascites (OC patients) or plasma, peritoneal fluid, and peritoneal washing (BP patients) were analyzed. The hydrodynamic radius (Rh) and the radius of gyration (Rg) of ENPs were calculated from the angular dependency of LS intensity for two ENP subpopulations. Rh and Rg of the predominant ENP population of OC patients were in the range 20–30 nm (diameter 40–60 nm). In thawed samples, larger particles (Rh mostly above 100 nm) were detected as well. The shape parameter ρ of both particle populations was around 1, which is typical for spherical particles with mass concentrated on the rim, as in vesicles. The Rh and Rg of ENPs in BP patients were larger than in OC patients, with ρ ≈ 1.1–2, implying a more elongated/distorted shape. These results show that SLS and DLS are promising methods for the analysis of morphological features of ENPs and have the potential to discriminate between OC and BP patients. However, further development of the methodology is required.


2013 ◽  
Vol 2013 ◽  
pp. 1-10 ◽  
Author(s):  
Emilia Tomaszewska ◽  
Katarzyna Soliwoda ◽  
Kinga Kadziola ◽  
Beata Tkacz-Szczesna ◽  
Grzegorz Celichowski ◽  
...  

Dynamic light scattering is a method that depends on the interaction of light with particles. This method can be used for measurements of narrow particle size distributions especially in the range of 2–500 nm. Sample polydispersity can distort the results, and we could not see the real populations of particles because big particles presented in the sample can screen smaller ones. Although the theory and mathematical basics of DLS technique are already well known, little has been done to determine its limits experimentally. The size and size distribution of artificially prepared polydisperse silver nanoparticles (NPs) colloids were studied using dynamic light scattering (DLS) and ultraviolet-visible (UV-Vis) spectroscopy. Polydisperse colloids were prepared based on the mixture of chemically synthesized monodisperse colloids well characterized by atomic force microscopy (AFM), transmission electron microscopy (TEM), DLS, and UV-Vis spectroscopy. Analysis of the DLS results obtained for polydisperse colloids reveals that several percent of the volume content of bigger NPs could screen completely the presence of smaller ones. The presented results could be extremely important from nanoparticles metrology point of view and should help to understand experimental data especially for the one who works with DLS and/or UV-Vis only.


2006 ◽  
Vol 352 (42-49) ◽  
pp. 5055-5059 ◽  
Author(s):  
Apostolos K. Rizos ◽  
Ioannis Tsikalas ◽  
Aristidis M. Tsatsakis ◽  
Michail I. Shtilman

2004 ◽  
Vol 4 (2) ◽  
pp. 76-83 ◽  
Author(s):  
Anna-Lena Kjøniksen ◽  
Stefania G. Baldursdóttir ◽  
Bo Nyström

Sign in / Sign up

Export Citation Format

Share Document