scholarly journals Three‐dimensional printed multicolor normal and abnormal fetal hearts based on ultrasound imaging data

2020 ◽  
Vol 55 (3) ◽  
pp. 421-422 ◽  
Author(s):  
Y.‐T. Guo ◽  
N. Hou ◽  
J.‐H. Liang ◽  
Z.‐K. Zhang ◽  
T.‐S. Cao ◽  
...  
Vascular ◽  
2021 ◽  
pp. 170853812199650
Author(s):  
Joseph Edwards ◽  
Hossam Abdou ◽  
Neerav Patel ◽  
Marta J Madurska ◽  
Kelly Poe ◽  
...  

Objectives Swine ( Sus Scrofa) are utilized broadly in research settings, given similarities to human vessel size and function; however, there are some important differences for clinicians to understand in order to interpret and perform translational research. This review article uses angiograms acquired in the course of a translational research program to present a description of the functional anatomy of the swine. Methods Digital subtraction angiography and computed tomography angiography were obtained throughout the course of multiple studies utilizing power injection with iodinated contrast. Subtracted two-dimensional images and three-dimensional multiplanar reformations were utilized post image acquisition to create maximal intensity projections and three-dimensional renderings of using open-source software (OsiriX). These imaging data are presented along with vessel measurements for reference. Results An atlas highlighting swine vascular anatomy, with an emphasis on inter-species differences that may influence how studies are conducted and interpreted, was compiled. Conclusions Swine are utilized in broad-reaching fields for preclinical research. While many similarities between human and swine vasculature exist, there are important differences to consider when conducting and interpreting research. This review article highlights these differences and presents accompanying images to inform clinicians gaining experience in swine research.


Sensors ◽  
2021 ◽  
Vol 21 (8) ◽  
pp. 2858
Author(s):  
Kelly Ka-Lee Lai ◽  
Timothy Tin-Yan Lee ◽  
Michael Ka-Shing Lee ◽  
Joseph Chi-Ho Hui ◽  
Yong-Ping Zheng

To diagnose scoliosis, the standing radiograph with Cobb’s method is the gold standard for clinical practice. Recently, three-dimensional (3D) ultrasound imaging, which is radiation-free and inexpensive, has been demonstrated to be reliable for the assessment of scoliosis and validated by several groups. A portable 3D ultrasound system for scoliosis assessment is very much demanded, as it can further extend its potential applications for scoliosis screening, diagnosis, monitoring, treatment outcome measurement, and progress prediction. The aim of this study was to investigate the reliability of a newly developed portable 3D ultrasound imaging system, Scolioscan Air, for scoliosis assessment using coronal images it generated. The system was comprised of a handheld probe and tablet PC linking with a USB cable, and the probe further included a palm-sized ultrasound module together with a low-profile optical spatial sensor. A plastic phantom with three different angle structures built-in was used to evaluate the accuracy of measurement by positioning in 10 different orientations. Then, 19 volunteers with scoliosis (13F and 6M; Age: 13.6 ± 3.2 years) with different severity of scoliosis were assessed. Each subject underwent scanning by a commercially available 3D ultrasound imaging system, Scolioscan, and the portable 3D ultrasound imaging system, with the same posture on the same date. The spinal process angles (SPA) were measured in the coronal images formed by both systems and compared with each other. The angle phantom measurement showed the measured angles well agreed with the designed values, 59.7 ± 2.9 vs. 60 degrees, 40.8 ± 1.9 vs. 40 degrees, and 20.9 ± 2.1 vs. 20 degrees. For the subject tests, results demonstrated that there was a very good agreement between the angles obtained by the two systems, with a strong correlation (R2 = 0.78) for the 29 curves measured. The absolute difference between the two data sets was 2.9 ± 1.8 degrees. In addition, there was a small mean difference of 1.2 degrees, and the differences were symmetrically distributed around the mean difference according to the Bland–Altman test. Scolioscan Air was sufficiently comparable to Scolioscan in scoliosis assessment, overcoming the space limitation of Scolioscan and thus providing wider applications. Further studies involving a larger number of subjects are worthwhile to demonstrate its potential clinical values for the management of scoliosis.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Xing Huang ◽  
Ni Fan ◽  
Hai-jun Wang ◽  
Yan Zhou ◽  
Xudong Li ◽  
...  

AbstractThe application of 3D printing in planning endoscopic endonasal transsphenoidal surgery is illustrated based on the analysis of patients with intracranial skull base diseases who received treatment in our department. Cranial computed tomography/magnetic resonance imaging data are attained preoperatively, and three-dimensional reconstruction is performed using MIMICS (Materialise, Leuven, Belgium). Models of intracranial skull base diseases are printed using a 3D printer before surgery. The models clearly demonstrate the morphologies of the intracranial skull base diseases and the spatial relationship with adjacent large vessels and bones. The printing time of each model is 12.52–15.32 h, and the cost ranges from 900 to 1500 RMB. The operative approach was planned in vitro, and patients recovered postoperatively well without severe complications or death. In a questionnaire about the application of 3D printing, experienced neurosurgeons achieved scores of 7.8–8.8 out of 10, while unexperienced neurosurgeons achieved scores of 9.2–9.8. Resection of intracranial skull base lesions is demonstrated to be well assisted by 3D printing technique, which has great potential in disclosing adjacent anatomical relationships and providing the required help to clinical doctors in preoperative planning.


Author(s):  
P.G Young ◽  
T.B.H Beresford-West ◽  
S.R.L Coward ◽  
B Notarberardino ◽  
B Walker ◽  
...  

Image-based meshing is opening up exciting new possibilities for the application of computational continuum mechanics methods (finite-element and computational fluid dynamics) to a wide range of biomechanical and biomedical problems that were previously intractable owing to the difficulty in obtaining suitably realistic models. Innovative surface and volume mesh generation techniques have recently been developed, which convert three-dimensional imaging data, as obtained from magnetic resonance imaging, computed tomography, micro-CT and ultrasound, for example, directly into meshes suitable for use in physics-based simulations. These techniques have several key advantages, including the ability to robustly generate meshes for topologies of arbitrary complexity (such as bioscaffolds or composite micro-architectures) and with any number of constituent materials (multi-part modelling), providing meshes in which the geometric accuracy of mesh domains is only dependent on the image accuracy (image-based accuracy) and the ability for certain problems to model material inhomogeneity by assigning the properties based on image signal strength. Commonly used mesh generation techniques will be compared with the proposed enhanced volumetric marching cubes (EVoMaCs) approach and some issues specific to simulations based on three-dimensional image data will be discussed. A number of case studies will be presented to illustrate how these techniques can be used effectively across a wide range of problems from characterization of micro-scaffolds through to head impact modelling.


Eye ◽  
1996 ◽  
Vol 10 (1) ◽  
pp. 75-81 ◽  
Author(s):  
Dónal B Downey ◽  
David A Nicolle ◽  
Morris F Levin ◽  
Aaron Fenster

Sign in / Sign up

Export Citation Format

Share Document