scholarly journals Evaluation of different mathematical models for diffusion-weighted imaging of normal prostate and prostate cancer using high b-values: A repeatability study

2014 ◽  
Vol 73 (5) ◽  
pp. 1988-1998 ◽  
Author(s):  
Ivan Jambor ◽  
Harri Merisaari ◽  
Pekka Taimen ◽  
Peter Boström ◽  
Heikki Minn ◽  
...  
2021 ◽  
Vol 11 ◽  
Author(s):  
Harri Merisaari ◽  
Hanne Laakso ◽  
Heidi Liljenbäck ◽  
Helena Virtanen ◽  
Hannu J. Aronen ◽  
...  

PurposeTo evaluate fitting quality and repeatability of four mathematical models for diffusion weighted imaging (DWI) during tumor progression in mouse xenograft model of prostate cancer.MethodsHuman prostate cancer cells (PC-3) were implanted subcutaneously in right hind limbs of 11 immunodeficient mice. Tumor growth was followed by weekly DWI examinations using a 7T MR scanner. Additional DWI examination was performed after repositioning following the fourth DWI examination to evaluate short term repeatability. DWI was performed using 15 and 12 b-values in the ranges of 0-500 and 0-2000 s/mm2, respectively. Corrected Akaike information criteria and F-ratio were used to evaluate fitting quality of each model (mono-exponential, stretched exponential, kurtosis, and bi-exponential).ResultsSignificant changes were observed in DWI data during the tumor growth, indicated by ADCm, ADCs, and ADCk. Similar results were obtained using low as well as high b-values. No marked changes in model preference were present between the weeks 1−4. The parameters of the mono-exponential, stretched exponential, and kurtosis models had smaller confidence interval and coefficient of repeatability values than the parameters of the bi-exponential model.ConclusionStretched exponential and kurtosis models showed better fit to DWI data than the mono-exponential model and presented with good repeatability.


2020 ◽  
Vol 30 (6) ◽  
pp. 3236-3244
Author(s):  
Yuxin Zhang ◽  
Shane A. Wells ◽  
Benjamin L. Triche ◽  
Frederick Kelcz ◽  
Diego Hernando

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jianxing Qiu ◽  
Jing Liu ◽  
Zhongxu Bi ◽  
Xiaowei Sun ◽  
Xin Wang ◽  
...  

Abstract Purpose To compare integrated slice-specific dynamic shimming (iShim) diffusion weighted imaging (DWI) and single-shot echo-planar imaging (SS-EPI) DWI in image quality and pathological characterization of rectal cancer. Materials and methods A total of 193 consecutive rectal tumor patients were enrolled for retrospective analysis. Among them, 101 patients underwent iShim-DWI (b = 0, 800, and 1600 s/mm2) and 92 patients underwent SS-EPI-DWI (b = 0, and 1000 s/mm2). Qualitative analyses of both DWI techniques was performed by two independent readers; including adequate fat suppression, the presence of artifacts and image quality. Quantitative analysis was performed by calculating standard deviation (SD) of the gluteus maximus, signal intensity (SI) of lesion and residual normal rectal wall, apparent diffusion coefficient (ADC) values (generated by b values of 0, 800 and 1600 s/mm2 for iShim-DWI, and by b values of 0 and 1000 s/mm2 for SS-EPI-DWI) and image quality parameters, such as signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of primary rectal tumor. For the primary rectal cancer, two pathological groups were divided according to pathological results: Group 1 (well-differentiated) and Group 2 (poorly differentiated). Statistical analyses were performed with p < 0.05 as significant difference. Results Compared with SS-EPI-DWI, significantly higher scores of image quality were obtained in iShim-DWI cases (P < 0.001). The SDbackground was significantly reduced on b = 1600 s/mm2 images and ADC maps of iShim-DWI. Both SNR and CNR of b = 800 s/mm2 and b = 1600 s/mm2 images in iShim-DWI were higher than those of b = 1000 s/mm2 images in SS-EPI-DWI. In primary rectal cancer of iShim-DWI cohort, SIlesion was significantly higher than SIrectum in both b = 800 and 1600 s/mm2 images. ADC values were significantly lower in Group 2 (0.732 ± 0.08) × 10− 3 mm2/s) than those in Group 1 ((0.912 ± 0.21) × 10− 3 mm2/s). ROC analyses showed significance of ADC values and SIlesion between the two groups. Conclusion iShim-DWI with b values of 0, 800 and 1600 s/mm2 is a promising technique of high image quality in rectal tumor imaging, and has potential ability to differentiate rectal cancer from normal wall and predicting pathological characterization.


Sign in / Sign up

Export Citation Format

Share Document