Influence of pH on corrosion behavior of carbon steel in simulated cooling water containing scale and corrosion inhibitors

2020 ◽  
Vol 71 (8) ◽  
pp. 1266-1275
Author(s):  
Jiahui Yao ◽  
Honghua Ge ◽  
Yi Zhang ◽  
Xiaojie Wang ◽  
Siyu Xie ◽  
...  
2011 ◽  
Vol 347-353 ◽  
pp. 3135-3138
Author(s):  
Hong Hua Ge ◽  
Jie Ting Tao ◽  
Xiao Ming Gong ◽  
Cheng Jun Wei ◽  
Xue Min Xu

Abstract: The effect of electromagnetic treatment on corrosion behavior of carbon steel and stainless steel in simulated cooling water was investigated by electrochemical impedance spectroscopy, potentiodynamic polarization techniques and water analysis. It was found that the charge transfer resistance decreased and the corrosion current density increased after electromagnetic treatment for carbon steel electrode, which shows that such treatment promotes corrosion of carbon steel in simulated cooling water. In contrast, the pitting potential of 316L stainless steel electrode rose which revealed that electromagnetic treatment of the experimental water exhibited corrosion inhibition to 316L stainless steel. Reasons for different corrosion behavior of the two metals were discussed.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Liang Liu ◽  
Ting-Ting Cao ◽  
Qi-Wei Zhang ◽  
Chong-Wei Cui

Circulating cooling water plays an important role in industrial water use. In this study, the corrosion inhibition effects of PBTCA, HEDP, and ATMP organic phosphorus inhibitors were investigated using the weight loss method by varying the dosage of inhibitors, ClO2 concentrations, and pH values on carbon steel in recirculating cooling water with a low concentration of ClO2 solution. The results showed that the three corrosion inhibitors had a satisfactory corrosion inhibition effect and that corrosion inhibition efficiency is positively correlated with the concentration of organic phosphorus inhibitors and pH. The average corrosion inhibition efficiency of the three inhibitors was about 80% at the concentration of inhibitors = 35 mg/L, pH = 9.0, and the concentration of ClO2 = 7.0 mg/L, of which the single-phosphorus molecular corrosion inhibitor proved to be the best inhibitor. When the ClO2 concentration was 7 mg/L, the corrosion inhibition efficiencies of the three corrosion inhibitors were relatively stable. Using the density functional theory (DFT) algorithm in the Gaussian 09 program, the optimization calculation was completed by the B3LYP/6-31G (d, p) method at the microlevel. The molecular structures of the three organic phosphorus inhibitors and the number of phosphorus-containing atoms were compared to the sustained-release properties. Organic phosphorus inhibitors, as an electronic buffer, not only provided electrons but also received electrons. They formed a complex with iron and zinc ions in water in order to attach to the surface of the carbon steel and to alleviate corrosion. In addition, the adsorption with a metal surface followed the Langmuir adsorption isotherm.


CORROSION ◽  
10.5006/1770 ◽  
2015 ◽  
Vol 71 (12) ◽  
pp. 1452-1466 ◽  
Author(s):  
Frederick Pessu ◽  
Richard Barker ◽  
Anne Neville

2020 ◽  
Vol 65 (1) ◽  
pp. 77-82
Author(s):  
Simona CAPRARESCU ◽  
◽  
Violeta PURCAR ◽  
Cristina MODROGAN ◽  
◽  
...  

2008 ◽  
Author(s):  
Yutaka Yokoyama ◽  
Rieko Takahashi ◽  
Hidekazu Asano ◽  
Naoki Taniguchi ◽  
Morimasa Naito

2020 ◽  
Vol 57 (1) ◽  
pp. 45-56 ◽  
Author(s):  
Eman A. Ghiaty ◽  
Dalia E. Mohamed ◽  
Emad A. Badr ◽  
Elshafie A. M. Gad ◽  
Elsayed A. Soliman ◽  
...  

Sign in / Sign up

Export Citation Format