Optimization and validation of the kinetic spectrophotometric method for quantitative determination of the pesticide atrazine and its application in infant formulae and cereal‐based baby food

2019 ◽  
Vol 99 (12) ◽  
pp. 5424-5431
Author(s):  
Emilija Pecev‐Marinković ◽  
Ana Miletić ◽  
Snežana Tošić ◽  
Aleksandra Pavlović ◽  
Danijela Kostic ◽  
...  
2015 ◽  
Vol 2015 ◽  
pp. 1-6 ◽  
Author(s):  
Ali Mohammad Akhoundi-Khalafi ◽  
Masoud Reza Shishehbore

Dexamethasone is a type of steroidal medications that is prescribed in many cases. In this study, a new reaction system using kinetic spectrophotometric method for quantitative determination of dexamethasone is proposed. The method is based on the catalytic effect of dexamethasone on the oxidation of Orange G by bromate in acidic media. The change in absorbance as a criterion of the oxidation reaction progress was followed spectrophotometrically. To obtain the maximum sensitivity, the effective reaction variables were optimized. Under optimized experimental conditions, calibration graph was linear over the range 0.2–54.0 mg L−1. The calculated detection limit (3sb/m) was 0.14 mg L−1for six replicate determinations of blank signal. The interfering effect of various species was also investigated. The present method was successfully applied for the determination of dexamethasone in pharmaceutical and biological samples satisfactorily.


Author(s):  
Mouhammed Khateeb ◽  
Basheer Elias ◽  
Fatema Al Rahal

A simple and sensitive kinetic spectrophotometric method has been developed for the determination of folic acid (FA) in bulk and pharmaceutical Formulations. The method is based on the oxidation of FA by Fe (III) in sulfuric acid medium. Fe (III) subsequently reduces to Fe (II) which is coupled with potassium ferricyanide to form Prussian blue. The reaction is followed spectrophotometrically by measuring the increase in absorbance at λmax 725 nm. The rate data and fixed time methods were adopted for constructing the calibration curves. The linearity range was found to be 1–20 μg mL-1 for each method. The correlation coefficient was 0.9978 and 0.9993, and LOD was found to be 0.91 and 0.09 μg mL-1 for rate data and fixed time methods, respectively. The proposed method has been successfully applied to the determination of FA in formulations with no interference from the excipients. Statical comparison of the results shows that there is no significant difference between the proposed and pharmacopoeial methods


2006 ◽  
Vol 22 (2) ◽  
pp. 333-336 ◽  
Author(s):  
Mansour Arab CHAMJANGALI ◽  
Vahid KELEY ◽  
Ghadamali BAGHERIAN

2010 ◽  
Vol 7 (4) ◽  
pp. 1612-1620 ◽  
Author(s):  
M. Keyvanfard ◽  
N. Abedi

A new, simple, sensitive and selective kinetic spectrophotometric method was developed for the determination of ultra trace amounts of vanadium(V). The method is based on the catalytic effect of vanadium(V) on the oxidation of malachite green oxalate (MG) by bromate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of malachite green oxalate (MG) at 625 nm with a fixed-time method. The decrease in the absorbance of MG is proportional to the concentration of vanadium(V) in the range of 1-100 ng/mL with a fixed time of 0.5-2 min from the initiation of the reaction. The limit of detection is 0.71 ng/mL of vanadium(V). The relative standard deviation for the determination of 5, 30, 50 ng/mL of vanadium(V) was2.5% 2.6%, 2.4% and respectively. The method was applied to the determination of vanadium(V) in water samples.


2013 ◽  
Vol 2013 ◽  
pp. 1-5
Author(s):  
Mohsen Keyvanfard ◽  
Khadijeh Alizad ◽  
Razieh Shakeri

A new kinetic spectrophotometric method is described for the determination of ultratrace amounts of sodium cromoglycate (SCG). The method based on catalytic action of SCG on the oxidation of amaranth with periodate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of the amaranth at 518 nm, for the first 4 min from initiation of the reaction. Calibration curve was linear in the range of 4.0−36.0 ng mL−1SCG. The limit of detection is 2.7 ng mL−1SCG. The relative standard deviation (RSD) for ten replicate analyses of 12, 20, and 28 ng mL−1SCG was 0.40%, 0.32%, and 0.53%, respectively. The proposed method was used for the determination of SCG in biological samples.


Sign in / Sign up

Export Citation Format

Share Document