Three-dimensional computational comparison of mini pinned heat sinks using different nanofluids: Part one-the hydraulic-thermal characteristics

2019 ◽  
Vol 49 (1) ◽  
pp. 591-613 ◽  
Author(s):  
Amer Al-damook ◽  
Mohanad A. Alfellag ◽  
Wissam H. Khalil
2020 ◽  
Vol 319 ◽  
pp. 02004
Author(s):  
Muhammad Akif Rahman ◽  
Md Badrath Tamam ◽  
Md Sadman Faruque ◽  
A.K.M. Monjur Morshed

In this paper a numerical analysis of three-dimensional laminar flow through rectangular channel heat sinks of different geometric configuration is presented and a comparison of thermal performance among the heat sinks is discussed. Liquid water was used as coolant in the aluminum made heat sink with a glass cover above it. The aspect ratio (section height to width) of rectangular channels of the mini-channel heat sink was 0.33. A heat flux of 20 W/cm2 was continuously applied at the bottom of the channel with different inlet velocity for Reynold’s number ranging from 150 to 1044. Interconnectors and obstacles at different positions and numbers inside the channel were introduced in order to enhance the thermal performance. These modifications cause secondary flow between the parallel channels and the obstacles disrupt the boundary layer formation of the flow inside the channel which leads to the increase in heat transfer rate. Finally, Nusselt number, overall thermal resistance and maximum temperature of the heat sink were calculated to compare the performances of the modified heat sinks with the conventional mini channel heat sink and it was observed that the heat sink with both interconnectors and obstacles enhanced the thermal performance more significantly than other configurations. A maximum of 36% increase in Nusselt number was observed (for Re =1044).


2021 ◽  
Vol 42 ◽  
pp. 102976
Author(s):  
Huanhuan Li ◽  
Ashwani Saini ◽  
Chengyang Liu ◽  
Jufeng Yang ◽  
Yaping Wang ◽  
...  

Author(s):  
Ali Radwan ◽  
Meshack Hawi ◽  
Mahmoud Ahmed

In this study, an efficient cooling technique for concentrator photovoltaic (CPV) cells is proposed to enhance the system electrical efficiency and extend its lifetime. To do this, a comprehensive three-dimensional conjugate heat transfer model of CPV cells layers coupled with the heat transfer and fluid flow model inside jet impingement heat sink is developed. Four different jet impingement designs are compared. The investigated designs are (A) central inlet jet, (B) Hypotenuse inlet jet, (C) staggered inlet jet, and (D) conventional jet impingement design with side drainage. The effect of coolant flowrate on the CPV/T system performance is investigated. The model is numerically simulated and validated using the available experiments. The performance of CPV system is investigated at solar concentration ratios of 20 and coolant flowrate up to 6000g/min. It is found that increasing the flowrate from 60 g/min to 600 g/min decrease the maximum cell temperature by 31°C for the configuration D while increasing the flowrate from 600 g/min to 6000 g/min reduce the cell temperature by 20.2°C. It is also concluded that at a higher flowrate of 6000g/min, all the investigated configurations relatively achieve better temperature uniformity with maximum temperature differences of 0.9 °C, 2.1 °C, 3.6 °C, and 3.9 °C for configurations A, B, C, and D respectively.


1999 ◽  
Author(s):  
James D. Lee ◽  
Majid T. Manzari ◽  
Yin-Lin Shen ◽  
Wenjun Zeng

Abstract The three-dimensional transient thermal problem of work rolls in the entire hot rolling process has been formulated. It includes the time-varying boundary conditions specified at the roll surface taking the schedule of both rolling and idling cycles into consideration. The corresponding finite element equations are derived and solved by the Runge-Kutta-Verner method. The finite element solutions indicate that the temperature variations in the circumferential direction are overwhelming. Case studies unveil the thermal characteristics of the work rolls in various kinds of mill operations. Numerical results are presented and compared with Guo’s analytical solutions.


2020 ◽  
Vol 172 ◽  
pp. 115167
Author(s):  
Xuehong Chen ◽  
Fengzhong Sun ◽  
Xin Li ◽  
Huadong Song ◽  
Peng Zheng ◽  
...  

2019 ◽  
Vol 142 (1) ◽  
Author(s):  
Xiao Cheng ◽  
Huiying Wu

Abstract Pillar microchannel heat sinks have been widely used for chip cooling, while their overall heat transfer performance is restricted by the stagnation flow in pillar wake zone. In this work, a simple but effective method using slit microstructure modified on pillar was proposed to enhance wake zone heat transfer. It enables a special flow path for the incoming fluid that intensively disturbs the wake fluid. To validate the proposed method, a three-dimensional simulation was employed to study the laminar flow and heat transfer characteristics in the slit pillar microchannel. The pillar without slit design was also investigated for comparative analysis. Effects of slit angle (θ), height over diameter ratio (H/D), and blocking ratio (D/W) of a single pillar were systematically studied at the Reynolds numbers of 26–260. Results showed the case with θ = 0 deg always demonstrated lower surface temperature, higher Nusselt number and higher thermal performance index (TPI) compared to other cases with different slit angles at the same conditions. Furthermore, it was interesting to find that the slit configuration was not suitable for long pillar microchannel, but preferred for high blocking ratio pillar microchannel at present ranges (H/D ≤ 1, D/W ≤ 0.5). The slit pillar array microchannel was also explored and observed with improved overall heat transfer performance. The proposed slit microstructure well prevents the heat transfer deterioration in pillar wake zone, which is promisingly to be used for cooling performance improvement of electronic device.