Unsteady numerical investigation of back-step three-dimensional slots on film cooling effectiveness

2009 ◽  
Vol 38 (1) ◽  
pp. 15-24
Author(s):  
He-Peng Yuan ◽  
Hui-Ren Zhu ◽  
Man-Zhao Kong ◽  
Hai-Yong Liu
Author(s):  
Lesley M. Wright ◽  
Stephen T. McClain ◽  
Charles P. Brown ◽  
Weston V. Harmon

A novel, double hole film cooling configuration is investigated as an alternative to traditional cylindrical and fanshaped, laidback holes. This experimental investigation utilizes a Stereo-Particle Image Velocimetry (S-PIV) to quantitatively assess the ability of the proposed, double hole geometry to weaken or mitigate the counter-rotating vortices formed within the jet structure. The three-dimensional flow field measurements are combined with surface film cooling effectiveness measurements obtained using Pressure Sensitive Paint (PSP). The double hole geometry consists of two compound angle holes. The inclination of each hole is θ = 35°, and the compound angle of the holes is β = ± 45° (with the holes angled toward one another). The simple angle cylindrical and shaped holes both have an inclination angle of θ = 35°. The blowing ratio is varied from M = 0.5 to 1.5 for all three film cooling geometries while the density ratio is maintained at DR = 1.0. Time averaged velocity distributions are obtained for both the mainstream and coolant flows at five streamwise planes across the fluid domain (x/d = −4, 0, 1, 5, and 10). These transverse velocity distributions are combined with the detailed film cooling effectiveness distributions on the surface to evaluate the proposed double hole configuration (compared to the traditional hole designs). The fanshaped, laidback geometry effectively reduces the strength of the kidney-shaped vortices within the structure of the jet (over the entire range of blowing ratios considered). The three-dimensional velocity field measurements indicate the secondary flows formed from the double hole geometry strengthen in the plane perpendicular to the mainstream flow. At the exit of the double hole geometry, the streamwise momentum of the jets is reduced (compared to the single, cylindrical hole), and the geometry offers improved film cooling coverage. However, moving downstream in the steamwise direction, the two jets form a single jet, and the counter-rotating vortices are comparable to those formed within the jet from a single, cylindrical hole. These strong secondary flows lift the coolant off the surface, and the film cooling coverage offered by the double hole geometry is reduced.


2022 ◽  
Author(s):  
Manoj Prabakar Sargunaraj ◽  
Andres Torres ◽  
Jose Garduna ◽  
Marcel Otto ◽  
Jayanta S. Kapat ◽  
...  

1986 ◽  
Vol 108 (1) ◽  
pp. 124-130 ◽  
Author(s):  
A. O. Demuren ◽  
W. Rodi ◽  
B. Scho¨nung

The present paper describes three-dimensional calculations of film cooling by injection from a single row of holes. A systematic study of the influence of different parameters on the cooling effectiveness has been carried out. Twenty-seven test cases have been calculated, varying the injection angle (α = 10/45/90 deg), the relative spacing (s/D = 1.5/3/5) and the blowing rate (M = 0.5/1/2) for the same mainstream conditions. The governing three-dimensional equations are solved by a finite volume method. The turbulent stresses and heat fluxes are obtained from a k–ε model modified to account for nonisotropic eddy viscosities and diffusivities. Examples of predicted velocity and temperature distributions are presented and compared with available experimental data. For all the test cases, the laterally averaged cooling effectiveness is given. On the whole, the agreement with experiments is fairly good, even though there are discrepancies about details in some of the cases. The influence of the individual parameters on the film cooling effectiveness is predicted correctly in all cases. This influence is discussed in some detail and the parameter combination with the best overall cooling performance is identified.


Author(s):  
D. Granser ◽  
T. Schulenberg

After compressor discharge air has initially been used to cool the heat shields of the hot gas inlet casing, it can subsequently be employed for film cooling of the first-stage vane shrouds. Since the flow field near these shrouds is three-dimensional, the film cooling effectiveness cannot be predicted correctly by common two-dimensional codes. The secondary flow transports the film from the pressure side to the suction side where it can even climb up the airfoil to cool its trailing section. Such film cooling effectiveness was first investigated experimentally in a linear vane cascade at atmospheric pressure. The temperatures and static pressure levels at the adiabatic shrouds, as well as the temperature measurements within the vane cascade, are reported for different cooling film blowing rates. In addition, the secondary flow was analysed numerically using a partially-parabolic computer code for 3D viscous flows. It involves mutual interaction of the boundary layer with the mainstream. The secondary flow can also be modelled with this algorithm, which requires less numerical effort than solving the fully 3D elliptic flow equations. The numerical results of the experiment and numerical predictions are compared. In addition, the application of these results to a high-temperature gas turbine is presented.


Author(s):  
Je-Chin Han ◽  
P. E. Jenkins

The intent of this work is to show, analytically, that superheated steam can provide better film cooling than conventional air for gas turbine blades and vanes. Goldstein’s two-dimensional and Eckert’s three-dimensional models have been reexamined and modified in order to include the effects of thermal-fluid properties of foreign gas injection on the film cooling effectiveness. Based on the modified models, the computed results for steam film cooling effectiveness, showing an increase of 80 to 100 percent when compared with air cooling at the same operating conditions, are presented.


2014 ◽  
Vol 695 ◽  
pp. 389-392
Author(s):  
Shahin Salimi ◽  
Nor Azwadi Che Sidik ◽  
Leila Jahanshaloo ◽  
Kianpour Ehsan

A numerical simulation has been performed for the investigation of flow and heat transfer characteristics of a film cooling injected through a hole with cylindrical and compound angle orientation. This paper presents the effects of coolant injector configuration of cylindrical and compound cooling holes with alignment angle of 30 degree at blowing ratio, BR = 3.18 on the film cooling effectiveness near the end wall surface of a combustor simulator. In the current research a three dimensional representation of Pratt and Whitney gas turbine engine was simulated and analyzed with a commercial finite volume package ANSYS FLUENT 14.0. This study has been performed with Reynolds-averaged Navier-Stokes turbulence model (RANS) on internal cooling passages The results indicate that using compound angle cooling holes injection, give much better protection than that obtained when simple angle cooling holes were used.


Author(s):  
Gazi I. Mahmood ◽  
Ross Gustafson ◽  
Sumanta Acharya

The measured flow field and temperature field near a three-dimensional asymmetric contour endwall employed in a linear blade cascade are presented with and without film-cooling flow on the endwall. Flow field temperature and Nusselt number distributions along the asymmetric endwall with wall heating and no film-cooling flow are also reported to show local high heat transfer region on the endwall and justify the locations of the coolant holes. Adiabatic film-cooling effectiveness along the endwall is then measured to indicate the local effects of the coolant jets. The near endwall flow field and temperature field provide the coolant flow behavior and the interaction of coolant jets with the boundary layer flow. Thus, the local film-cooling effectiveness can be explained with the coolant jet trajectories. The measurements are obtained at the Reynolds number of 2.30×105 based on blade actual chord and inlet velocity, coolant-to-free stream temperature ratio of 0.93, and coolant-to-free stream density ratio of 1.06. The cascade employs the hub side blade section and passage geometry of the first stage rotor of GE-E3 turbine engine. The contour endwall profile is employed on the bottom endwall only in the cascade. The blowing ratio of the film-cooling flow varies from 1.0 to 2.4 from 71 discrete cylindrical holes located in the contour endwall. The three-dimensional profile of the endwall varies in height in both the pitchwise and axial directions. The flow field is quantified with the streamwise vorticity and turbulent intensity, pitchwise static pressure difference, flow yaw angle, and pitchwise velocity. Both the flow field and temperature data indicate that the coolant jets cover more distance in the pitchwise and axial direction in the passage as the blowing ratio increases. Thus, the local and average film-cooling effectiveness increase with the blowing ratio.


Author(s):  
M. T. Schobeiri ◽  
K. Lu ◽  
J. C. Han

The impact of the purge flow injection on aerodynamics and film cooling effectiveness of a high pressure turbine with non-axisymmetric endwall contouring has been numerically investigated. For this purpose, the geometry and boundary condition of a three-stage turbine at the Turbomachinery Performance and Flow Research Laboratory (TPFL), Texas A&M University is utilized. The turbine is being prepared to experimentally verify the results of the current numerical investigations. Its rotor includes non-axisymmetric endwall contouring on the first and second rotor row. In the preceding paper [1] it was shown that the endwall contouring of the second rotor contouring was able to substantially increase the turbine efficiency. To investigate the film cooling in conjunction with a purge flow injection, the first turbine rotor hub was contoured. Applying the same contouring method, however, different aerodynamic behavior of the first rotor was observed due to its immediate exposure to the purge flow injection. Consequently, the endwall design of the first rotor row required particular attention. The purge flow investigation involves the reference case without endwall contouring followed by the investigation with endwall contouring. The turbine used for this numerical investigation has two independent cooling loops. The first loop supplies coolant air to the stator-rotor gap, while the second loop provides cooling air to the downstream discrete film-cooling holes and blade tip cooling injection holes. For the current investigations the second loop is closed. Film cooling effectiveness is numerically simulated for rotor frequency of 2400 rpm. Efficiency, pressure, temperature and film cooling effectiveness distributions are determined for purge mass flow ratios of MFR = 0.5%, 1.0% and 2.0%. The small amount of the injected mass flow drastically changes the development of the secondary flow structure of the contoured first turbine row partially reversing the improvement tendency obtained from the endwall contouring.


Author(s):  
Jin Wang ◽  
Bengt Sundén ◽  
Min Zeng ◽  
Qiu-Wang Wang

Three-dimensional simulations of the squealer tip on the GE-E3 blade with eight film cooling holes were carried out. To form the wake by the trailing edges of the stator vanes, cylindrical rods and delta wings were placed upstream of the blades. The rods were placed according to three positions, and the influence on the film cooling effectiveness was calculated. Because delta wings were placed upstream of the blades to generate in the vane passage, the passage flow also was investigated. However, the passage vortex generated by the delta wings had a profound effect on the passage flow distribution. For the squealer tip, the cavity contributes to the improvement of the cooling effect in the tip zone. The passage flow and the tip leakage flow influenced by cylindrical rods and delta wings were analyzed using numerical simulations with the blowing ratio of M = 0.5. In addition, calculations with and without cylindrical rods and delta wings were performed and then comparisons were enabled. It was found that the vortex created by delta wings made the passage flow more turbulent and the result indicates a slight effect on the film cooling effectiveness in the tip gap.


Sign in / Sign up

Export Citation Format

Share Document