scholarly journals Development of a temperature gradient focusing method for in situ extraterrestrial biomarker analysis

2008 ◽  
Vol 29 (15) ◽  
pp. 3107-3114 ◽  
Author(s):  
Grégoire Danger ◽  
David Ross
Author(s):  
Zhengwei Ge ◽  
Chun Yang

Microfluidic concentration of sample species is achieved using the temperature gradient focusing (TGF) in a microchannel with a step change in the cross-section under a pure direct current (DC) field or a combined alternating current (AC) and DC electric field. Experiments were carried out to study the effects of applied voltage, buffer concentration and channel size on sample concentration in the TGF processes. These effects were analyzed and summarized using a dimensionless Joule number that is introduced in this study. In addition, Joule number effect in the Poly-dimethylsiloxane (PDMS)/PDMS microdevice was compared with the PDMS/Glass microdevice. A more than 450-fold concentration enhancement was obtained within 75 seconds in the PDMS/PDMS microdevice. Results also showed that the high frequency AC electric field which contributes to produce the temperature gradient and reduces the required DC voltage for the sample concentration. The lower DC voltage has generated slower electroosmotic flow (EOF), which reduces the backpressure effect associated with the finite reservoir size. Finally, a more than 2500-fold concentration enhancement was obtained within 14 minutes in the PDMS/PDMS microdevice, which was a great achievement in this TGF technique using inherent Joule heating effects.


Author(s):  
M. Akbari ◽  
M. Bahrami ◽  
D. Sinton

An optothermal analyte preconcentration method is introduced in this work based on temperature gradient focusing. The present approach offers a flexible, noncontact technique for focusing and transporting of analytes. Here, we use a commercial video projector and an optical system to generate heat and control the heat source position, size and power. This heater is used to focus a sample model analyte, fluorescent dye, at an arbitrary location along the microchannel. Optothermal manipulation of the focused band was demonstrated by projecting a series of images with a moving light band.


Author(s):  
Amitava Dutta ◽  
Apurba Kumar Santra ◽  
Ranjan Ganguly

Abstract We present a detailed numerical analysis of electrophoresis induced concentration of a bio-analyte facilitated by temperature gradient focusing in a phosphate buffer solution via Joule heating inside a converging-diverging microchannel. The purpose is to study the effects of frequency of AC field and channel width variation on the concentration of target analyte. We tune the buffer viscosity, conductivity and electrophoretic mobility of the analyte such that the electrophoretic velocity of the analyte locally balances the electroosmotic flow of the buffer, resulting in a local build-up of the analyte concentration in a target region. An AC field is superimposed on the applied DC field within the microchannel in such a way that the back pressure effect is minimized, resulting in minimum dispersion and high concentration of the target analyte. Axial transport of fluorescein-Na in the phosphate buffer solution is controlled by inducing temperature gradient through Joule heating. The technique leverages the fact that the buffer's ionic strength and viscosity depends on temperature, which in turn guides the analyte transport. A numerical model is proposed and a finite element-based solution of the coupled electric field, mass, momentum, energy and species equations are carried out. Simulation predict peak of 670-fold concentration of fluorescein-Na is achieved. The peak concentration is found to increase sharply as the channel throat width, while the axial spread of concentrated analyte increases at lower frequency of AC field. The results of the work may improve the design of micro concentrator.


Sensors ◽  
2020 ◽  
Vol 20 (18) ◽  
pp. 5275
Author(s):  
Seongsoo Kim ◽  
Sang-Myung Lee ◽  
Je Pil Yoon ◽  
Namhun Lee ◽  
Jinhyo Chung ◽  
...  

Graphene oxide (GO)/peptide complexes as a promising disease biomarker analysis platform have been used to detect proteolytic activity by observing the turn-on signal of the quenched fluorescence upon the release of peptide fragments. However, the purification steps are often cumbersome during surface modification of nano-/micro-sized GO. In addition, it is still challenging to incorporate the specific peptides into GO with proper orientation using conventional immobilization methods based on pre-synthesized peptides. Here, we demonstrate a robust magnetic GO (MGO) fluorescence resonance energy transfer (FRET) platform based on in situ sequence-specific peptide synthesis of MGO. The magnetization of GO was achieved by co-precipitation of an iron precursor solution. Magnetic purification/isolation enabled efficient incorporation of amino-polyethylene glycol spacers and subsequent solid-phase peptide synthesis of MGO to ensure the oriented immobilization of the peptide, which was evaluated by mass spectrometry after photocleavage. The FRET peptide MGO responded to proteases such as trypsin, thrombin, and β-secretase in a concentration-dependent manner. Particularly, β-secretase, as an important Alzheimer’s disease marker, was assayed down to 0.125 ng/mL. Overall, the MGO platform is applicable to the detection of other proteases by using various peptide substrates, with a potential to be used in an automated synthesis system operating in a high throughput configuration.


2008 ◽  
Vol 80 (1) ◽  
pp. 172-178 ◽  
Author(s):  
Matthew S. Munson ◽  
J. Mark Meacham ◽  
Laurie E. Locascio ◽  
David Ross

2013 ◽  
Vol 135 (9) ◽  
Author(s):  
M. Gao ◽  
L. Gui ◽  
J. Liu

Temperature gradient focusing (TGF) is a highly efficient focusing technique for the concentration and separation of charged analytes in microfluidic channels. The design of an appropriate temperature gradient is very important for the focusing efficiency. In this study, we proposed a new technique to generate the temperature gradient. This technique utilizes a microchannel filled with liquid-metal as an electrical heater in a microfluidic chip. By applying an electric current, the liquid-metal heater generates Joule heat, forming the temperature gradient in the microchannel. To optimize the temperature gradient and find out the optimal design for the TGF chip, numerical simulations on four typical designs were studied. The results showed that design 1 can provide a best focusing method, which has the largest temperature gradient. For this best design, the temperature is almost linearly distributed along the focusing microchannel. The numerical simulations were then validated both theoretically and experimentally. The following experiment and theoretical analysis on the best design also provide a useful guidance for designing and fabricating the liquid-metal based TGF microchip.


2020 ◽  
Vol 98 (9) ◽  
pp. 27-35
Author(s):  
Takahiro Komiyama ◽  
Takashi Sasabe ◽  
Hiroshi Naito ◽  
Katsuyuki Kawamura ◽  
Toshiyuki Suzuki ◽  
...  

2005 ◽  
Vol 127 (8) ◽  
pp. 806-806 ◽  
Author(s):  
David Huber ◽  
Juan G. Santiago