False-positive FDG PET/CT uptake in Warthin tumor in head and neck oncological patients confirmed by a fine needle aspiration

2011 ◽  
Vol 40 (3) ◽  
pp. 282-284 ◽  
Author(s):  
Jerzy Klijanienko ◽  
Slavomir Petras ◽  
Lucile De Bosschere ◽  
Benoît Paulmier ◽  
Christophe Le Tourneau ◽  
...  
Cancers ◽  
2020 ◽  
Vol 12 (12) ◽  
pp. 3544
Author(s):  
David N. Poller ◽  
Hakim Megadmi ◽  
Matthew J. A. Ward ◽  
Pierpaolo Trimboli

This study assesses the role of [18F] FDG PET/CT, fine needle aspiration (FNA) cytology and ultrasound in the 1–2% of patients with focally positive thyroid nodules on FDG PET/CT. All FDG PET/CT scans with focally increased thyroid FDG PET/CT uptake performed over 37 months in one institution were matched to patients undergoing thyroid FNA. Diffuse FDG PET/CT uptake patients were excluded. A total of 47 patients showed focally increased thyroid uptake. Consistent with previous studies, 18 (38.2%) patients had malignancy—12 primary thyroid carcinoma, 1 parathyroid carcinoma, 3 metastatic carcinoma to the thyroid and 2 lymphoma. A total of 15 (31.9%) lesions categorized as non-malignant contained Hürthle cells/oncocytes. A total of 14 lesions (29.8%) had focally increased FDG PET/CT uptake with no specific cytological or histopathological cause identified. No focally PET avid Hürthle cell/oncocytic lesions were found to be malignant. Exclusion of oncocytic lesions increased the calculated risk of malignancy (ROM) of focally PET avid nodules from 38% to 68%. It may be useful to exclude focally FDG PET/CT avid Hürthle cell/oncocytic lesions, typically reported as follicular neoplasm or suspicious for a follicular neoplasm, Hürthle cell type (Oncocytic) type, RCPath Thy 3F: Bethesda IV or sometimes Thy 3a: Bethesda III FNAs) from ROM calculations. Oncocytic focally PET/CT FDG avid lesions appear of comparatively lower risk of malignancy and require investigation or operation but these lesions should be readily identified by FNA cytology on diagnostic work up of focally PET avid thyroid nodules.


2018 ◽  
Vol 89 (5) ◽  
pp. 642-648 ◽  
Author(s):  
Pierpaolo Trimboli ◽  
Gaetano Paone ◽  
Giorgio Treglia ◽  
Camilla Virili ◽  
Teresa Ruberto ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-4
Author(s):  
R. C. L. Chan ◽  
Y. W. Chan

Background.Accurate assessment of irradiated neck in squamous cell carcinoma of the head and neck (HNSCC) is essential. Fine-needle aspiration cytology is often performed for suspicious lesions but it is limited by its low negative predictive value (NPV). We postulated that F-18 fluorodeoxyglucose (FDG) positron emission tomography combined with computed tomography (PET/CT) can overcome this limitation by its high NPV value and allow for a more accurate assessment of irradiated neck in HNSCC.Methods.Fifty-four HNSCC patients were included for the study. They all received previous irradiation to the neck. Clinical characteristics, details of radiotherapy, PET/CT results, follow-up findings, and final histological diagnosis were analyzed.Results.The sensitivity, specificity, positive predictive value (PPV), and NPV were 95.8%, 96.7%, 95.8%, and 96.7%, respectively. Age, sex, radiation dose, interval between PET/CT and radiotherapy completion, nature of radiotherapy, and use of second course of radiotherapy were not found to affect diagnostic accuracy of PET/CT. A new algorithm for investigation of masses in irradiated neck is proposed.Conclusions.PET/CT is an effective diagnostic tool and has a complementary role to FNAC in the management of irradiated neck in head and neck cancers, particularly in cases where suspicious lesions were identified but FNAC showed negative results.


2013 ◽  
Vol 38 (1) ◽  
pp. e38-e39 ◽  
Author(s):  
Kuruva Manohar ◽  
Anish Bhattacharya ◽  
Sameer Vyas ◽  
Pranab Dey ◽  
Arup Kumar Mandal ◽  
...  