scholarly journals Case study and application of process analytical technology (PAT) towards bioprocessing: Use of tryptophan fluorescence as at-line tool for making pooling decisions for process chromatography

2009 ◽  
Vol 25 (5) ◽  
pp. 1433-1439 ◽  
Author(s):  
Anurag S. Rathore ◽  
Xiaohui Li ◽  
Wojciech Bartkowski ◽  
Ashutosh Sharma ◽  
Yuefeng Lu
2005 ◽  
Vol 6 (2) ◽  
pp. E284-E297 ◽  
Author(s):  
Robert P. Cogdill ◽  
Carl A. Anderson ◽  
James K. Drennen

2020 ◽  
Author(s):  
Sobhana Alekhya Sripada ◽  
Sushmitha Krishnan ◽  
Rajan Bhawnani ◽  
Jessica Molek ◽  
Aparajith Bhaskar ◽  
...  

2020 ◽  
Author(s):  
Sobhana Alekhya Sripada ◽  
Sushmitha Krishnan ◽  
Rajan Bhawnani ◽  
Jessica Molek ◽  
Aparajith Bhaskar ◽  
...  

2019 ◽  
Author(s):  
Zied Hosni ◽  
Nazer Rajoub ◽  
Ian Houson ◽  
Alison Nordon ◽  
Brahim Benyahia ◽  
...  

Liquid-liquid extraction is a technique of extraction heavily used in chemical industry and especially for purification of pharmaceuticals. Trimetozine was used as a case study to test the performance of an implemented platform capable of conducting the extraction of the analyte of interest from its impurities using a washing solvent. Three stages of pairs of mix-er-settler were designed for a full control of the streams flow rates, the temperature, and the speed of stirring. The countercurrent extraction was chosen with an inline IR sensor as a Process Analytical Technology and a Partial Least Squares model to quantify the partitioning of the different analytes in the downstream of the platform. The dynamics of the extraction was followed experimentally and simulated in MATLAB in order to build black-box model.


2019 ◽  
Author(s):  
Zied Hosni ◽  
Nazer Rajoub ◽  
Ian Houson ◽  
Alison Nordon ◽  
Brahim Benyahia ◽  
...  

Liquid-liquid extraction is a technique of extraction heavily used in chemical industry and especially for purification of pharmaceuticals. Trimetozine was used as a case study to test the performance of an implemented platform capable of conducting the extraction of the analyte of interest from its impurities using a washing solvent. Three stages of pairs of mix-er-settler were designed for a full control of the streams flow rates, the temperature, and the speed of stirring. The countercurrent extraction was chosen with an inline IR sensor as a Process Analytical Technology and a Partial Least Squares model to quantify the partitioning of the different analytes in the downstream of the platform. The dynamics of the extraction was followed experimentally and simulated in MATLAB in order to build black-box model.


2020 ◽  
Author(s):  
Sobhana Alekhya Sripada ◽  
Sushmitha Krishnan ◽  
Rajan Bhawnani ◽  
Jessica Molek ◽  
Aparajith Bhaskar ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document