Single‐Crystalline Perovskite Microlasers for High‐Contrast and Sub‐Diffraction Imaging

2019 ◽  
Vol 29 (39) ◽  
pp. 1904868 ◽  
Author(s):  
Kaiyang Wang ◽  
Shuai Wang ◽  
Shumin Xiao ◽  
Nan Zhang ◽  
Yujie Wang ◽  
...  
Geophysics ◽  
2021 ◽  
pp. 1-72
Author(s):  
Parsa Bakhtiari Rad ◽  
Craig J. Hickey

Seismic diffractions carry the signature of near-surface high-contrast anomalies and need to be extracted from the data to complement the reflection processing and other geophysical techniques. Since diffractions are often masked by reflections, surface waves and noise, a careful diffraction separation is required as a first step for diffraction imaging. A multiparameter time-imaging method is employed to separate near-surface diffractions. The implemented scheme makes use of the wavefront attributes that are reliable fully data-derived processing parameters. To mitigate the effect of strong noise and wavefield interference in near-surface data, the proposed workflow incorporates two wavefront-based parameters, dip angle and coherence, as additional constraints. The output of the diffraction separation is a time trace-based stacked section that provides the basis for further analysis and applications such as time migration. To evaluate the performance of the proposed wavefront-based workflow, it is applied to two challenging field data sets that were collected over small culverts in very near-surface soft soil environments. The results of the proposed constrained workflow and the existing unconstrained approach are presented and compared. The proposed workflow demonstrates superiority over the existing method by attenuating more reflection and noise, leading to improved diffraction separation. The abundance of unmasked diffractions reveal that the very near-surface is highly scattering. Time migration is carried out to enhance the anomaly detection by focusing of the isolated diffractions. Although strong diffractivity is observed at the approximate location of the targets, there are other diffracting zones observed in the final sections that might bring uncertainties for interpretation.


2019 ◽  
Vol 27 (6) ◽  
pp. 8092 ◽  
Author(s):  
António Pereira ◽  
Mafalda Sousa ◽  
Ana C. Almeida ◽  
Luísa T. Ferreira ◽  
Ana Rita Costa ◽  
...  

2013 ◽  
Vol 11 (2) ◽  
pp. 021103-21105 ◽  
Author(s):  
Xingchen Pan Xingchen Pan ◽  
Suhas P. Veetil Suhas P. Veetil ◽  
Cheng Liu Cheng Liu ◽  
Qiang Lin Qiang Lin ◽  
Jianqiang Zhu Jianqiang Zhu

2013 ◽  
Author(s):  
Byung-Wook Yoo ◽  
Trevor Chan ◽  
Mischa Megens ◽  
Tianbo Sun ◽  
Weijian Yang ◽  
...  

Author(s):  
Joseph D. C. Peng

The relative intensities of the ED spots in a cross-grating pattern can be calculated using N-beam electron diffraction theory. The scattering matrix formulation of N-beam ED theory has been previously applied to imperfect microcrystals of gold containing stacking disorder (coherent twinning) in the (111) crystal plane. In the present experiment an effort has been made to grow single-crystalline, defect-free (111) gold films of a uniform and accurately know thickness using vacuum evaporation techniques. These represent stringent conditions to be met experimentally; however, if a meaningful comparison is to be made between theory and experiment, these factors must be carefully controlled. It is well-known that crystal morphology, perfection, and orientation each have pronounced effects on relative intensities in single crystals.The double evaporation method first suggested by Pashley was employed with some modifications. Oriented silver films of a thickness of about 1500Å were first grown by vacuum evaporation on freshly cleaved mica, with the substrate temperature at 285° C during evaporation with the deposition rate at 500-800Å/sec.


Author(s):  
Russell L. Steere ◽  
Eric F. Erbe ◽  
J. Michael Moseley

We have designed and built an electronic device which compares the resistance of a defined area of vacuum evaporated material with a variable resistor. When the two resistances are matched, the device automatically disconnects the primary side of the substrate transformer and stops further evaporation.This approach to controlled evaporation in conjunction with the modified guns and evaporation source permits reliably reproducible multiple Pt shadow films from a single Pt wrapped carbon point source. The reproducibility from consecutive C point sources is also reliable. Furthermore, the device we have developed permits us to select a predetermined resistance so that low contrast high-resolution shadows, heavy high contrast shadows, or any grade in between can be selected at will. The reproducibility and quality of results are demonstrated in Figures 1-4 which represent evaporations at various settings of the variable resistor.


Author(s):  
J.N. Turner ◽  
M. Siemens ◽  
D. Szarowski ◽  
D.N. Collins

A classic preparation of central nervous system tissue (CNS) is the Golgi procedure popularized by Cajal. The method is partially specific as only a few cells are impregnated with silver chromate usualy after osmium post fixation. Samples are observable by light (LM) or electron microscopy (EM). However, the impregnation is often so dense that structures are masked in EM, and the osmium background may be undesirable in LM. Gold toning is used for a subtle but high contrast EM preparation, and osmium can be omitted for LM. We are investigating these preparations as part of a study to develop correlative LM and EM (particularly HVEM) methodologies in neurobiology. Confocal light microscopy is particularly useful as the impregnated cells have extensive three-dimensional structure in tissue samples from one to several hundred micrometers thick. Boyde has observed similar preparations in the tandem scanning reflected light microscope (TSRLM).


Author(s):  
Uwe Lücken ◽  
Michael Felsmann ◽  
Wim M. Busing ◽  
Frank de Jong

A new microscope for the study of life science specimen has been developed. Special attention has been given to the problems of unstained samples, cryo-specimens and x-ray analysis at low concentrations.A new objective lens with a Cs of 6.2 mm and a focal length of 5.9 mm for high-contrast imaging has been developed. The contrast of a TWIN lens (f = 2.8 mm, Cs = 2 mm) and the BioTWTN are compared at the level of mean and SD of slow scan CCD images. Figure 1a shows 500 +/- 150 and Fig. 1b only 500 +/- 40 counts/pixel. The contrast-forming mechanism for amplitude contrast is dependent on the wavelength, the objective aperture and the focal length. For similar image conditions (same voltage, same objective aperture) the BioTWIN shows more than double the contrast of the TWIN lens. For phasecontrast specimens (like thin frozen-hydrated films) the contrast at Scherzer focus is approximately proportional to the √ Cs.


Author(s):  
Akira Tonomura

Electron holography is a two-step imaging method. However, the ultimate performance of holographic imaging is mainly determined by the brightness of the electron beam used in the hologram-formation process. In our 350kV holography electron microscope (see Fig. 1), the decrease in the inherently high brightness of field-emitted electrons is minimized by superposing a magnetic lens in the gun, for a resulting value of 2 × 109 A/cm2 sr. This high brightness has lead to the following distinguished features. The minimum spacing (d) of carrier fringes is d = 0.09 Å, thus allowing a reconstructed image with a resolution, at least in principle, as high as 3d=0.3 Å. The precision in phase measurement can be as high as 2π/100, since the position of fringes can be known precisely from a high-contrast hologram formed under highly collimated illumination. Dynamic observation becomes possible because the current density is high.


Sign in / Sign up

Export Citation Format

Share Document