scholarly journals 2D versus 3D real time ultrasound with live xPlane imaging to visualize aortic and ductal arches: comparison between methods

PeerJ ◽  
2018 ◽  
Vol 6 ◽  
pp. e4561
Author(s):  
Stefania Dell’Oro ◽  
Maria Verderio ◽  
Maddalena Incerti ◽  
Salvatore Andrea Mastrolia ◽  
Sabrina Cozzolino ◽  
...  

Background The diagnosis of congenital heart defects is challenging, especially for what concerns conotruncal anomalies. Indeed, although the screening techniques of fetal cardiac anomalies have greatly improved, the detection rate of conotruncal anomalies still remains low due to the fact that they are associated with a normal four-chamber view. Therefore, the study aimed to compare real-time three-dimensional echocardiography with live xPlane imaging with two-dimensional (2D) traditional imaging in visualizing ductal and aortic arches during routine echocardiography of the second trimester of gestation. Methods This was an observational prospective study including 114 women with uncomplicated, singleton pregnancies. All sonographic studies were performed by two different operators, of them 60 by a first level operator, while 54 by a second level operator. A subanalysis was run in order to evaluate the feasibility and the time needed for the two procedures according to fetal spine position and operator’s experience. Results The measurements with 2D ultrasound were performed in all 114 echocardiographies, while live xPlane imaging was feasible in the 78% of the cases, and this was mainly due to fetal position. The time lapse needed to visualize aortic and ductal arches was significantly lower when using 2D ultrasound compared to live xPlane imaging (29.56 ± 28.5 s vs. 42.5 ± 38.1 s, P = 0.006 for aortic arch; 22.14 ± 17.8 s vs. 37.1 ± 33.8 s, P = 0.001 for ductal arch), also when performing a subanalysis according to operators’ experience (P < 0.05 for all comparisons). Feasibility of live xPlane proved to be correlated with the position of the fetal spine and the operator’s experience. Discussion To find a reproducible and standardized method to detect fetal heart defects may bring a great benefit for both patients and operators. In this scenario live xPlane imaging is a novel method to visualize ductal and aortic arches. We found that the position of the fetal spine may affect the feasibility of the method since, when the fetal back is anterior or transverse, the visualization of the correct view of three-vessels and trachea in order to set the reference line properly becomes more challenging. In addition, the fetal spine position influences the duration of the ultrasound examination. Regarding operator’s skills and experience, in our study a first level operator was able to perform the complete 2D and xPlane examination in a lower number of cases compared to second level operators. In addition, the time required for the complete examination was higher for first level operators. This means that this technique is based on an adequate operators’ expertise.

2019 ◽  
Vol 10 (1) ◽  
Author(s):  
Julián Tachella ◽  
Yoann Altmann ◽  
Nicolas Mellado ◽  
Aongus McCarthy ◽  
Rachael Tobin ◽  
...  

Abstract Single-photon lidar has emerged as a prime candidate technology for depth imaging through challenging environments. Until now, a major limitation has been the significant amount of time required for the analysis of the recorded data. Here we show a new computational framework for real-time three-dimensional (3D) scene reconstruction from single-photon data. By combining statistical models with highly scalable computational tools from the computer graphics community, we demonstrate 3D reconstruction of complex outdoor scenes with processing times of the order of 20 ms, where the lidar data was acquired in broad daylight from distances up to 320 metres. The proposed method can handle an unknown number of surfaces in each pixel, allowing for target detection and imaging through cluttered scenes. This enables robust, real-time target reconstruction of complex moving scenes, paving the way for single-photon lidar at video rates for practical 3D imaging applications.


2012 ◽  
Vol 39 (3) ◽  
pp. 316-321 ◽  
Author(s):  
Y. Xiong ◽  
M. Chen ◽  
L. W. Chan ◽  
Y. H. Ting ◽  
T. Y. Fung ◽  
...  

2015 ◽  
Vol 209 (4) ◽  
pp. 609-619 ◽  
Author(s):  
Carlas S. Smith ◽  
Stephan Preibisch ◽  
Aviva Joseph ◽  
Sara Abrahamsson ◽  
Bernd Rieger ◽  
...  

Imaging single proteins or RNAs allows direct visualization of the inner workings of the cell. Typically, three-dimensional (3D) images are acquired by sequentially capturing a series of 2D sections. The time required to step through the sample often impedes imaging of large numbers of rapidly moving molecules. Here we applied multifocus microscopy (MFM) to instantaneously capture 3D single-molecule real-time images in live cells, visualizing cell nuclei at 10 volumes per second. We developed image analysis techniques to analyze messenger RNA (mRNA) diffusion in the entire volume of the nucleus. Combining MFM with precise registration between fluorescently labeled mRNA, nuclear pore complexes, and chromatin, we obtained globally optimal image alignment within 80-nm precision using transformation models. We show that β-actin mRNAs freely access the entire nucleus and fewer than 60% of mRNAs are more than 0.5 µm away from a nuclear pore, and we do so for the first time accounting for spatial inhomogeneity of nuclear organization.


2010 ◽  
Vol 151 (21) ◽  
pp. 854-863 ◽  
Author(s):  
Attila Nemes ◽  
Marcel L. Geleijnse ◽  
Osama I. I. Soliman ◽  
Wim B. Vletter ◽  
Jackie S. McGhie ◽  
...  

Jelenleg az echokardiográfia a legszéleskörűbben alkalmazott rutin noninvazív diagnosztikus eljárás, amelynek segítségével a mitralis billentyű morfológiája és funkciója jellemezhető. Ennek az összefoglaló jellegű közleménynek a célja az egyik legújabb echokardiográfiás fejlesztés, a transthoracalis real-time háromdimenziós echokardiográfia szerepének bemutatása a mitralis billentyű vizsgálatában.


Sign in / Sign up

Export Citation Format

Share Document