scholarly journals Lung ultrasound in the diagnosis of pneumonia in children: proposal for a new diagnostic algorithm

PeerJ ◽  
2015 ◽  
Vol 3 ◽  
pp. e1374 ◽  
Author(s):  
Giulio Iorio ◽  
Maria Capasso ◽  
Giuseppe De Luca ◽  
Salvatore Prisco ◽  
Carlo Mancusi ◽  
...  

Background.Despite guideline recommendations, chest radiography (CR) for the diagnosis of community-acquired pneumonia (CAP) in children is commonly used also in mild and/or uncomplicated cases. The aim of this study is to assess the reliability of lung ultrasonography (LUS) as an alternative test in these cases and suggest a new diagnostic algorithm.Methods.We reviewed the medical records of all patients admitted to the pediatric ward from February 1, 2013 to December 31, 2014 with respiratory signs and symptoms. We selected only cases with mild/uncomplicated clinical course and in which CR and LUS were performed within 24 h of each other. The LUS was not part of the required exams recorded in medical records but performed independently. The discharge diagnosis, made only on the basis of history and physical examination, laboratory and instrumental tests, including CR (without LUS), was used as a reference test to compare CR and LUS findings.Results.Of 52 selected medical records CAP diagnosis was confirmed in 29 (55.7%). CR was positive in 25 cases, whereas LUS detected pneumonia in 28 cases. Four patients with negative CR were positive in ultrasound findings. Instead, one patient with negative LUS was positive in radiographic findings. The LUS sensitivity was 96.5% (95% CI [82.2%–99.9%]), specificity of 95.6% (95% CI [78.0%–99.9%]), positive likelihood ratio of 22.2 (95% CI [3.2–151.2]), and negative likelihood ratio of 0.04 (95% CI [0.01–0.25]) for diagnosing pneumonia.Conclusion.LUS can be considered as a valid alternative diagnostic tool of CAP in children and its use must be promoted as a first approach in accordance with our new diagnostic algorithm.

Author(s):  
Fatma Hegazy ◽  
Emad Aboelnasr ◽  
Amr A. Abdel-Aziem ◽  
In-Ju Kim

Background: Clinical diagnosis of Paediatric flexible flatfoot is still a challenging issue for the healthcare professionals. Clarke's Angle (CA) is frequently used clinically for assessing foot posture; however there is still a debate about its validity and diagnostic accuracy in evaluation of static foot posture especially in Paediatric population with some previous studies supporting, while the others are refuting its validity. The current study aimed to investigate validity and diagnostic accuracy of CA using radiographic findings as a criterion standard measure to determine flexible flatfoot between ages of 6-18 years. Methods: A cross-sectional study conducted on 612 participants (1224 feet) with flexible flatfoot aged 6-18 years (12.36 {plus minus}3.39) was recruited. The clinical measures results were compared to the criterion standard radiographic measures and displayed on the receiver operating characteristic curve (ROC) and the area under ROC curve (AUC) was computed. Intra-rater reliability, sensitivity, specificity, predictive values, and likelihood ratios were calculated for CA. Fagan nomogram was used to detect the posttest probability. Results: Clarke's angle (CA) demonstrated higher intra-rater reliability (ICC=0.99). CA showed higher sensitivity (98.4%), specificity (98.8), positive predictive value (97.3), negative predictive value (99.3), positive likelihood ratio (84) and negative likelihood ratio (0.02). AUC was 0.98[95%CI= 0095-1.00]. The positive likelihood ratio (LR+) yielded a posttest probability of 97%, while the negative likelihood ratio (LR−) yielded a posttest probability of 0.02. Conclusions: CA is a valid with high diagnostic accuracy in diagnosis of flexible flatfoot between the ages of 6-18 years.


2021 ◽  
Vol 11 (1) ◽  
pp. 24
Author(s):  
Alexandra Malinovska ◽  
Liliana Malinovska ◽  
Christian H. Nickel ◽  
Roland Bingisser

Assessments of history and body temperature are cornerstones of the diagnostic workup in all patients presenting to emergency departments (ED). Yet, the objective measurement of temperature and the subjective perception of fever can differ. This is a secondary exploratory analysis of a consecutive all-comer study, performed at an adult ED in Switzerland. Trained medical students interviewed all patients if fever was present. Altered temperature (>38.0 °C/<36.0 °C) measured at triage using an ear thermometer was used as the reference standard for diagnostic performance. In case of a disagreement between fever symptoms and altered temperature, discordance was noted. Outcome measures for case severity (acute morbidity, hospitalization, intensive care, and in-hospital mortality) were extracted from the electronic health records. Odds ratios (OR) for discordance between signs and symptoms and outcomes were calculated. Among 2183 patients, 325 patients reported fever symptoms. The sensitivity of fever symptoms as a test for altered temperature was 36.3%. Specificity was 91.5%. The negative predictive value was 84.1%, positive likelihood ratio was 4.2 and negative likelihood ratio was 0.7. The adjusted OR for discordance between fever symptoms and altered temperature was 1.71 (95% CI: 1.2–2.44) for acute morbidity, 1.56 (95% CI: 1.13–2.15) for hospitalization, and 1.12 (95% CI: 0.64–1.59) for intensive care. Unadjusted OR for mortality was 1.5 (95% CI: 0.69–3.25). Fever symptoms and altered temperature broadly overlap, but presentations can be stratified according to concordance between signs and symptoms. In case of discordance, the odds for acute morbidity and hospitalization are increased. Discordance may therefore be further investigated as a red flag for a serious outcome.


2021 ◽  
Vol 20 ◽  
pp. 153303382110119
Author(s):  
Wen-Ting Zhang ◽  
Guo-Xun Zhang ◽  
Shuai-Shuai Gao

Background: Leukemia is a common malignant disease in the human blood system. Many researchers have proposed circulating microRNAs as biomarkers for the diagnosis of leukemia. We conducted a meta-analysis to evaluate the diagnostic accuracy of circulating miRNAs in the diagnosis of leukemia. Methods: A comprehensive literature search (updated to October 13, 2020) in PubMed, EMBASE, Web of Science, Cochrane Library, Wanfang database and China National Knowledge Infrastructure (CNKI) was performed to identify eligible studies. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) for diagnosing leukemia were pooled for both overall and subgroup analysis. The meta-regression and subgroup analysis were performed to explore heterogeneity and Deeks’ funnel plot was used to assess publication bias. Results: 49 studies from 22 publications with a total of 3,489 leukemia patients and 2,756 healthy controls were included in this meta-analysis. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and area under the curve were 0.83, 0.92, 10.8, 0.18, 59 and 0.94, respectively. Subgroup analysis shows that the microRNA clusters of plasma type could carry out a better diagnostic accuracy of leukemia patients. In addition, publication bias was not found. Conclusions: Circulating microRNAs can be used as a promising noninvasive biomarker in the early diagnosis of leukemia.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Bo Zhang ◽  
Bingjie Zhang ◽  
Zhulin Zhou ◽  
Yutong Guo ◽  
Dan Wang

AbstractObjectiveGlycosylated hemoglobin (HbA1c) has obvious clinical value in the diagnosis of diabetes, but the conclusions on the diagnostic value of diabetic retinopathy (DR) are not consistent. This study aims to comprehensively evaluate the accuracy of glycosylated hemoglobin in the diagnosis of diabetic retinopathy through the meta-analysis of diagnostic tests.MethodsCochrane Library, Embase, PubMed, Web of Science, China National Knowledge Infrastructure (CNKI), China Wanfang Database, Chinese Biomedical Literature Database (CBM) were searched until November, 2020. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to assess the quality of the included studies. The pooled sensitivity, specificity, positive likelihood ratio (+LR), negative likelihood ratio (-LR), diagnostic odds ratio (DOR) and areas under the receiver operating characteristic (ROC) curve were calculated by Stata 15.0 software.ResultsAfter screening, 18 high-quality papers were included. The results of meta-analysis showed that the combined DOR = 18.19 (95% CI: 10.99–30.11), the sensitivity= 0.81 (95% CI): 0.75 ~ 0.87), specificity = 0.81 (95%CI: 0.72 ~ 0.87), +LR = 4.2 (95%CI: 2.95 ~ 6.00), −LR = 0.23 (95%CI: 0.17 ~ 0.31), and the area under the Summary ROC curve was 0.88 (95%CI:  0.85 ~ 0.90).ConclusionThe overall accuracy of HbA1cC forin diagnosing diabetic retinopathy is good. As it is more stable than blood sugar and is not affected by meals, it may be a suitable indicator for diabetic retinopathy.


2021 ◽  
Vol 49 (3) ◽  
pp. 030006052199296
Author(s):  
Juan Wang ◽  
Liu Yang ◽  
Yanjun Diao ◽  
Jiayun Liu ◽  
Jinjie Li ◽  
...  

Objective To evaluate the performance of a DNA methylation-based digital droplet polymerase chain reaction (ddPCR) assay to detect aberrant DNA methylation in cell-free DNA (cfDNA) and to determine its application in the detection of hepatocellular carcinoma (HCC). Methods The present study recruited patients with liver-related diseases and healthy control subjects. Blood samples were used for the extraction of cfDNA, which was then bisulfite converted and the extent of DNA methylation quantified using a ddPCR platform. Results A total of 97 patients with HCC, 80 healthy control subjects and 46 patients with chronic hepatitis B/C virus infection were enrolled in the study. The level of cfDNA in the HCC group was significantly higher than that in the healthy control group. For the detection of HCC, based on a cut-off value of 15.7% for the cfDNA methylation ratio, the sensitivity and specificity were 78.57% and 89.38%, respectively. The diagnostic accuracy was 85.27%, the positive predictive value was 81.91% and the negative predictive value was 87.20%. The positive likelihood ratio of 15.7% in HCC diagnosis was 7.40, while the negative likelihood ratio was 0.24. Conclusions A sensitive methylation-based assay might serve as a liquid biopsy test for diagnosing HCC.


BMJ Open ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. e038088
Author(s):  
Jacky Tu ◽  
Peter Gowdie ◽  
Julian Cassar ◽  
Simon Craig

BackgroundSeptic arthritis is an uncommon but potentially significant diagnosis to be considered when a child presents to the emergency department (ED) with non-traumatic limp. Our objective was to determine the diagnostic accuracy of clinical findings (history and examination) and investigation results (pathology tests and imaging) for the diagnosis of septic arthritis among children presenting with acute non-traumatic limp to the ED.MethodsSystematic review of the literature published between 1966 and June 2019 on MEDLINE and EMBASE databases. Studies were included if they evaluated children presenting with lower limb complaints and evaluated diagnostic performance of items from history, physical examination, laboratory testing or radiological examination. Data were independently extracted by two authors, and quality assessment was performed using the Quality Assessment Tool for Diagnostic Accuracy Studies 2 tool.Results18 studies were identified, and included 2672 children (560 with a final diagnosis of septic arthritis). There was substantial heterogeneity in inclusion criteria, study setting, definitions of specific variables and the gold standard used to confirm septic arthritis. Clinical and investigation findings were reported using varying definitions and cut-offs, and applied to differing study populations. Spectrum bias and poor-to-moderate study design quality limit their applicability to the ED setting.Single studies suggest that the presence of joint tenderness (n=189; positive likelihood ratio 11.4 (95% CI 5.9 to 22.0); negative likelihood ratio 0.2 (95% CI 0.0 to 1.2)) and joint effusion on ultrasound (n=127; positive likelihood ratio 8.4 (95% CI 4.1 to 17.1); negative likelihood ratio 0.2 (95% CI 0.1 to 0.3)) appear to be useful. Two promising clinical risk prediction tools were identified, however, their performance was notably lower when tested in external validation studies.DiscussionDifferentiating children with septic arthritis from non-emergent disorders of non-traumatic limp remains a key diagnostic challenge for emergency physicians. There is a need for prospectively derived and validated ED-based clinical risk prediction tools.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 404.1-404
Author(s):  
V. Hax ◽  
R. Santo ◽  
L. Santos ◽  
M. Farinon ◽  
M. De Oliveira ◽  
...  

Background:Because the method of diagnosing sarcopenia is complex and is considered to be difficult to introduce into routine practice, the European Working Group on Sarcopenia in Older People’s (EWGSOP) recommends use of the SARC-F questionnaire as a way to introduce assessment and treatment of sarcopenia into clinical practice1. Only recently, some studies have focused their attention on the presence of sarcopenia in systemic sclerosis (SSc) and there is no data about the performance of SARC-F in this population.Objectives:To test the diagnostic properties of the SARC-F questionnaire for sarcopenia screening in SSc patients.Methods:Cross-sectional study, including 94 SSc patients assessed by clinical evaluation, laboratory and pulmonary function tests. Sarcopenia was evaluated using the EWGSOP diagnostic criteria updated in 2019 (EWGSOP2): dual-energy X-ray absorptiometry, handgrip strength, and short physical performance battery (SPPB)1. Participants also completed the SARC-F questionnaire. The questionnaires’ performances were evaluated through receiver operating characteristic (ROC) curves and standard measures of diagnostic accuracy were computed using the EWGSOP2 criteria as the gold standard for diagnosis of sarcopenia.Results:Sarcopenia was identified in 15 (15,9%) SSc patients by the EWGSOP2 criteria. Area under the ROC curve of SARC-F screening for sarcopenia was 0.588 (95% confidence interval (CI) 0.482, 0.688) (figure 1). The results of sensitivity, specificity, positive likelihood ratio (PLR) and negative likelihood ratio (NLR) with the EWGSOP2 criteria as the reference standard were 35.71 [95% CI, 12.76-64.86], 81.01 (95% CI, 70.62-88.97), 1.88 (95% CI, 0.81-4.35) and 0.79 (95% CI, 0.53-1.19), respectively. The optimal cut-off point of SARC-F in our sample was ≥ 4 (Youden index: 0.21), the same cut-off point recommended in the literature2,3. Only 6 (40%) out of the 15 participants with sarcopenia were identified by the SARC-F questionnaire in our population. However, the SARC-F properly identified 4 out of 5 patients who had severe sarcopenia.Conclusion:This is the first study to evaluate the performance of SARC-F questionnaire for sarcopenia screening in patients with SSc. Although it appropriately identifies severe cases of sarcopenia, the SARC-F alone may not be an adequate screening tool in high-risk populations, such as SSc, that may benefit from early intervention and treatment.References:[1]Cruz-Jentoft AJ, Bahat G, Bauer J, et al. Sarcopenia: Revised European consensus on definition and diagnosis. Age Ageing. 2019;48(1):16-31.[2]Malmstrom TK, Morley JE. SARC-F: A simple questionnaire to rapidly diagnose sarcopenia. J Am Med Dir Assoc. 2013;14(8):531-532.[3]Ida S, Kaneko R, Murata K. SARC-F for Screening of Sarcopenia Among Older Adults: A Meta-analysis of Screening Test Accuracy. J Am Med Dir Assoc. 2018;19(8):685-689.Disclosure of Interests:Vanessa Hax: None declared, Rafaela Santo: None declared, Leonardo Santos: None declared, Mirian Farinon: None declared, Marianne de Oliveira: None declared, Guilherme Levi Três: None declared, Andrese Aline Gasparin: None declared, M Bredemeier: None declared, Ricardo Xavier Consultant of: AbbVie, Pfizer, Novartis, Janssen, Eli Lilly, Roche, Rafael Mendonça da Silva Chakr: None declared


Open Medicine ◽  
2020 ◽  
Vol 15 (1) ◽  
pp. 266-273
Author(s):  
Min Tang ◽  
Jia Yang ◽  
Ying Li ◽  
Luhua Zhang ◽  
Ying Peng ◽  
...  

AbstractMatrix-assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) has become one of the most popular methods for the rapid and cost-effective detection of clinical pathogenic microorganisms. This study aimed to evaluate and compare the diagnostic performance of MALDI-TOF MS with that of conventional approaches for the direct identification of pathogens from urine samples. A systematic review was conducted based on a literature search of relevant databases. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and area under the summary receiver operating characteristic (SROC) curve of the combined studies were estimated. Nine studies with a total of 3920 subjects were considered eligible and included in the meta-analysis. The pooled sensitivity was 0.85 (95% CI 0.79-0.90), and the pooled specificity was 0.93 (95% CI 0.82-0.97). The PLR and NLR were 11.51 (95% CI 4.53-29.26) and 0.16 (95% CI 0.11-0.24), respectively. The area under the SROC curve was 0.93 (95% CI 0.91-0.95). Sensitivity analysis showed that the results of this meta-analysis were stable. MALDI-TOF MS could directly identify microorganisms from urine samples with high sensitivity and specificity.


2017 ◽  
Vol 7 (1) ◽  
Author(s):  
Xiuzhong Qi ◽  
Fangyong Yang ◽  
Haitao Huang ◽  
Yiqi Du ◽  
Yan Chen ◽  
...  

Abstract The early diagnosis and severity grading for acute pancreatitis (AP) are difficult to determine because of the complexity and differences in disease process. To date, few studies have investigated the role of lymphocyte ratio (LR) in AP. Therefore, the objective of the present study was to investigate the prognostic value of LR as an indicator in AP, as well as determine an optimal cut-off value for the severity prediction. There were two hundred four patients involved in this study, ninety-two of whom had severe acute pancreatitis (SAP). The LR was analyzed on admission and correlated with severity, which was determined using the Atlanta classification. The optimal cut-off value for LR was generated using receiving operator characteristic (ROC) curves. The results showed that the LR in the SAP group decreased significantly compared to the mild acute pancreatitis (MAP) group (8.82 vs. 13.43). The optimal cut-off value obtained from ROC curves was 0.081, with a sensitivity of 80.4%, a specificity of 53.3%, a positive likelihood ratio of 1.722, and a negative likelihood ratio of 0.368. In conclusion, the LR is obviously related to the condition of AP patients and is valuable for the differential diagnosis of SAP in early stages of AP.


2021 ◽  
Vol 4 (Supplement_1) ◽  
pp. 210-212
Author(s):  
R Trasolini ◽  
S Wong ◽  
B Salh

Abstract Background Fecal calprotectin is a non-invasive test of colonic inflammation used for monitoring inflammatory bowel disease activity and for risk stratifying non-specific colonic symptoms. Calprotectin is a leukocyte specific enzyme. A similar test, leukocyte esterase is used to detect leukocytes in urine and is widely available as a low-cost point-of-care test strip. We hypothesize that an unmodified version of the urine test strip would be highly accurate in predicting a positive fecal calprotectin test in a real world sample of patients. Aims To explore a low cost, rapid alternative to the fecal calprotectin test Methods All inpatient and outpatient stool samples tested for calprotectin by the Vancouver General Hospital laboratory from February 2020 to November 2020 were included prospectively. Samples were simultaneously tested for fecal leukocyte esterase using an unmodified Roche Cobas Chemstrip urinalysis test strip by central lab personnel. An identical aliquot was sent to LifeLabs for calprotectin as per standard protocol. All samples were suspended in buffer using established laboratory protocols prior to testing. Fecal leukocyte esterase results were reported as 0–4+ based on visual interpretation, calprotectin results were reported as mcg/g of stool. REB review and approval was obtained prior to data collection. Sensitivity, Specificity and AUROC were calculated using Microsoft Excel and JROCFIT. Results 26 samples were collected. Using a fecal calprotectin greater than 120 mcg/g as a gold standard an AUROC of 0.89 (SE= .06) was calculated. A leukocyte esterase reading of 2+ or greater had the best test characteristics based on ROC curve analysis. Using this cutoff, 21/26 samples were concordant, giving an accuracy of 80.8%, sensitivity of 90.9% and specificity of 73.3%. Positive likelihood ratio was 8.07 and negative likelihood ratio was 0.29. Assuming an AUROC of 0.8, the sample size N=26 is 90% powered (β=0.9) to predict the true AUROC within 0.1 with a type I error rate of .05 (α&lt;.05). Conclusions This study suggests application of a prepared stool sample to a urinalysis test strip gives a result highly predictive of a positive fecal calprotectin test. Further results are being collected prospectively to improve the robustness of these preliminary data. Secondary outcomes including comparison to endoscopy and biopsy results where available are planned if an adequate sample size can be accrued. Future studies justifying independent clinical use of leukocyte esterase would require a common gold standard comparator such as endoscopy. Fecal calprotectin testing is not universally insured and is not available as a rapid test strip. Use of fecal leukocyte esterase may reduce costs and shorten time to results if proven to be independently reliable. Funding Agencies None


Sign in / Sign up

Export Citation Format

Share Document