scholarly journals The relationship between shoulder injuries and flexibility, shoulder range of motion characteristics in elite male Japanese water polo players

2017 ◽  
Vol 66 (4) ◽  
pp. 263-269
Author(s):  
Eiichi Segawa ◽  
Yasuka Komori ◽  
Tatsuya Hojo
2020 ◽  
Vol 8 (7_suppl6) ◽  
pp. 2325967120S0040
Author(s):  
Caleb Gulledge ◽  
Toufic Jildeh ◽  
Joseph Tramer ◽  
Fabien Meta ◽  
Kevin Taylor ◽  
...  

Objectives: Overuse injuries in overhead athletes are becoming more prevalent, with an unclear relationship between shoulder biomechanics and medial elbow symptoms and injury. The purpose of this study was to investigate the relationship of shoulder range of motion to torque across the medial elbow in college pitchers using a validated MOTUS sensor baseball sleeve. Methods: Pitchers were recruited from three local university baseball teams. Exclusion criteria included injury or restricted activity due to pain. They were evaluated in the preseason, within two weeks before their first game of the season. Pitchers completed workload questionnaires and patient reported outcome measurement information system (PROMIS) pain interference (PI), physical function (PF), and upper extremity (UE) surveys. Shoulder range of motion and upper extremity lengths were measured bilaterally. After adequate warm-up, pitchers were fitted with a MOTUS sensor baseball sleeve (Motus Global, Massapequa, NY) and instructed to throw 5 fastballs in a standardized manner off the mound at game-speed effort. The sensor placed at the medial elbow reported elbow torque, arm speed, arm slot, and shoulder rotation for each pitch, while a radar gun measured peak ball velocity. The primary outcome was to evaluate the relationship between shoulder range of motion and increased stress across the medial elbow. Additional outcomes evaluated pitcher characteristics, demographics, and outcome scores. Outcomes were assessed via a multivariable model, which controlled for possible covariates. Results: Twenty-eight pitchers were included in the preseason analysis with an average (SD) age of 20.1 (1.3) years and playing experience of 15.3 (1.8) years, 2.5 (1.2) of those years at collegiate level. The dominant shoulder demonstrated decreased internal rotation (54.5+/-10.6 vs 65.8+/-9.1) and increased external rotation (ER, 94.1+/-10.4 vs 88.4+/-9.2) relative to the non-dominant side (p < 0.001), while total rotational range of motion (TRROM) was significantly decreased in the dominant arm (148.6+/-12.4 vs 154.1+/-10.6, p < 0.001). The average glenohumeral internal rotation deficiency (GIRD) was 11.3 (9.87) and average external rotation gain (ERG) was 5.71 (8.8). External rotation was found to be a predictor of arm stress, with an increase in 0.35 Nm of elbow torque for every degree increase in ER (beta = 0.35+/-0.06, p = 0.003); there was moderate correlation between ER and arm stress (r = .45, P<.001). Pitchers demonstrated significantly greater arm stress with the following shoulder ROM measurements: GIRD < 20 as compared to greater than 20 degrees (46.6 +/- 0.5 versus 43.5 +/- 1.1, P=.011), ERG greater than 5 as compared to < 5 degrees (47.4 +/- 0.7 versus 45.1 +/- 0.6, P=.014), and loss of total rotational ROM less than 5 as compared to > 5 degrees (46.6 +/- 0.5 versus 43.6 +/- 1.1, P=.013). Multivariate analysis demonstrated significant predictors of PROMIS PF and UE scores were arm stress, ERG, and GIRD (p<0.05), while increased PROMIS PI scores were predicted by increased ERG and GIRD (p<0.05). Conclusion: We found medial elbow stress, arm speed, arm slot, and shoulder rotation as measured by the MOTUS baseball sensor sleeve were influenced by rotational adaptations of the pitching shoulder in collegiate throwing athletes prior to their season. Likewise, arm stress and shoulder rotational adaptations were reflected as predictors of PROMIS PF, UE, and PI scores.


Author(s):  
Lafi S. Khalil ◽  
Toufic R. Jildeh ◽  
Kevin A. Taylor ◽  
Caleb M. Gulledge ◽  
D. Grace Smith ◽  
...  

2020 ◽  
Vol 19 ◽  
pp. 153473542096285
Author(s):  
Kyungsun Han ◽  
Ojin Kwon ◽  
Hyo-Ju Park ◽  
Ae-Ran Kim ◽  
Boram Lee ◽  
...  

This is a preliminary study to investigate the feasibility of electronic moxibustion in breast cancer patients with upper limb lymphedema. As current treatment options for lymphedema are unsatisfactory and time consuming, there have been attempts to manage symptoms using integrative treatments. Electronic moxibustion was developed to compensate for the shortcomings of conventional moxibustion and is widely used in clinical practice. However, there have been no studies on using electronic moxibustion in breast cancer-related lymphedema. To investigate the feasibility of electronic moxibustion in treating breast cancer-related lymphedema, this study included subjects who completed primary cancer treatment at least 6 months ago and had more than 10 mm difference in arm circumference of upper limbs. All subjects were assigned to the treatment group. Subjects were treated with 16 sessions (30 minutes/session) of electronic moxibustion for 8 weeks followed by 4 weeks of follow-up. For outcome measures, upper limb circumferences, shoulder range of motion, bioimpedance analysis, and quality of life questionnaire were assessed. All 10 subjects completed the study. The effective index showed 38.21% reduction after treatment ( P = .0098) and 29.35% ( P = .0039) after 4 weeks of follow-up compared to the baseline. The reduction of lymphedema was most prominent at 10 cm above the elbow crease, where the mean reduction of circumference difference was 7.5 mm ( P = .0430) and continued to improve after treatment (mean reduction of 8.3 mm, P = .0156). There was significant improvement in shoulder range of motion only in flexion and internal rotation at week 9. There were 7 adverse events, and most were irrelevant to the treatment. Only 1 participant had a mild burn on the acupuncture point. Here, we demonstrate for the first time that electronic moxibustion treatment is a feasible treatment for breast cancer-related lymphedema. Electronic moxibustion may reduce differences in upper limb circumference and improve shoulder range of motion. A future comparative clinical trial is needed to confirm the clinical efficacy of this treatment.


Author(s):  
Ya-Dong Wang ◽  
Yu-Xiang Ming ◽  
Yong-Hua Pang ◽  
Wei-Nan Chen ◽  
Xu-Hua Zong ◽  
...  

BACKGROUND: Persisting shoulder stiffness adversely affects quality of life by causing pain and motion restrictions especially in patients with diabetes. OBJECTIVE: The aim of this study was to evaluate the outcomes of arthroscopic capsular release in patients with idiopathic shoulder stiffness. METHOD: A literature search was conducted in electronic databases and studies were selected by following precise eligibility criteria. Random-effects meta-analyses were performed to estimate the changes at latest follow-up in scores of the Constant, American Shoulder and Elbow Surgeons (ASES), and University of California at Los Angelis (UCLA) scales, Visual Analogue Scale (VAS), and shoulder range of motion. RESULTS: Nineteen studies were included. The follow-up duration was 42 months [95% confidence interval (CI): 32, 51]. Improvements in scores of the Constant, ASES, UCLA scales, and VAS were 48.3 [95% CI: 38.0, 58.6], 44.6 [95% CI: 24.6, 64.6], 19.3 [95% CI: 16.6, 22.0], and -6.1 [95% CI: -6.9, -5.4] respectively (P< 0.05 all). Improvements in the shoulder range of motion were: abduction 82.0 [95% CI: 65.0, 98.9]; forward flexion 75.9 [95% CI: 59.7, 92.1]; external rotation 43.2 [95% CI: 37.5, 49.0]; and internal rotation 25.4 [95% CI: 15.2, 35.5] degrees; P< 0.05 all). CONCLUSION: Arthroscopic capsular release effectively improves shoulder function in patients with idiopathic shoulder stiffness.


2020 ◽  
Vol 05 (01) ◽  
pp. E8-E13
Author(s):  
Kenzie B. Friesen ◽  
Adam W. Anz ◽  
Jeffrey R. Dugas ◽  
James R. Andrews ◽  
Gretchen D. Oliver

AbstractCurrently it is hypothesized that increased body mass index may contribute to overuse injuries. Thus, if hip or shoulder range of motion is affected by body mass index, pitchers may be placing additional stress on joints as they seek to pitch at maximal velocity. The purpose of this study was to examine if range of motion at the hips and shoulders were related to body mass index classification. A sample of 147 female softball pitchers (17.0±4.2 years; 167.6±11.8 cm; 70.6±17.5 kg; body mass index=24.8±4.7 kg/m2) participated. Bilateral hip and shoulder range of motion were assessed. Multivariate analysis of variance results indicated body mass index [Wilks’ Λ=0.742, F=1.722, p=0.014, η2=0.095] significantly affected range of motion of the shoulder and hip. Post hoc results indicated the underweight group had significantly more range of motion than the obese group in hip internal range of motion on both the throwing side (mean difference=12.39, p=0.005) and glove side (mean difference=11.98, p=0.004). Although body composition is not overly emphasized among softball pitchers, the current study reveals excess weight may inhibit proper mechanics. Coaches, athletic trainers, strength and conditioning personnel, and athletes should acknowledge the role that body composition can play in affecting pitch outcomes.


2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Samantha K.L.A. Rizzi ◽  
Cinira A.S. Haddad ◽  
Patrícia S. Giron ◽  
Patrícia V.G. Figueira ◽  
Amanda Estevão ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document