scholarly journals Flat-top Brillouin gain spectrum with a controllable bandwidth produceal from multiple-lines pump modulation in liquid-core optical fibers

2013 ◽  
Vol 62 (19) ◽  
pp. 194206
Author(s):  
Gao Wei ◽  
Liu Sheng-Nan ◽  
Bi Ya-Feng ◽  
Hu Xiao-Bo ◽  
Pu Shao-Zhi ◽  
...  
2013 ◽  
Vol 102 (19) ◽  
pp. 191906 ◽  
Author(s):  
Mingjie Ding ◽  
Neisei Hayashi ◽  
Yosuke Mizuno ◽  
Kentaro Nakamura

Author(s):  
Yolande Sikali Mamdem ◽  
Ekaterina Burov ◽  
Louis-Anne De Montmorillon ◽  
Frédéric Taillade ◽  
Yves Jaouen ◽  
...  

2012 ◽  
Vol 20 (2) ◽  
pp. 1790 ◽  
Author(s):  
Y. Sikali Mamdem ◽  
E. Burov ◽  
L-A. de Montmorillon ◽  
Y. Jaouën ◽  
G. Moreau ◽  
...  

2016 ◽  
Vol 13 (3) ◽  
pp. 20151066-20151066 ◽  
Author(s):  
Heeyoung Lee ◽  
Neisei Hayashi ◽  
Yosuke Mizuno ◽  
Kentaro Nakamura

1997 ◽  
Vol 15 (10) ◽  
pp. 1842-1851 ◽  
Author(s):  
M. Nikles ◽  
L. Thevenaz ◽  
P.A. Robert

OSA Continuum ◽  
2020 ◽  
Vol 3 (10) ◽  
pp. 2902
Author(s):  
Sven Hochheim ◽  
Michael Steinke ◽  
Peter Wessels ◽  
Jörg Neumann ◽  
Dietmar Kracht

2011 ◽  
Vol 29 (1) ◽  
pp. 22-30 ◽  
Author(s):  
S Dasgupta ◽  
F Poletti ◽  
S Liu ◽  
P Petropoulos ◽  
D J Richardson ◽  
...  

Symmetry ◽  
2021 ◽  
Vol 13 (7) ◽  
pp. 1166
Author(s):  
Bin Liu ◽  
Jianping He ◽  
Shihai Zhang ◽  
Yinping Zhang ◽  
Jianan Yu ◽  
...  

Brillouin frequency shift (BFS) of distributed optical fiber sensor is extracted from the Brillouin gain spectrum (BGS), which is often characterized by Lorenz type. However, in the case of complex stress and optical fiber self damage, the BGS will deviate from Lorenz type and be asymmetric, which leads to the extraction error of BFS. In order to enhance the extraction accuracy of BFS, the Lorenz local single peak fitting algorithm was developed to fit the Brillouin gain spectrum curve, which can make the BSG symmetrical with respect to the Brillouin center frequency shift. One temperature test of a fiber-reinforced polymer (FRP) packaged sensor whose BSG curve is asymmetric was conducted to verify the idea. The results show that the local region curve of BSG processed by the developed algorithm has good symmetry, and the temperature measurement accuracy obtained by the developed algorithm is higher than that directly measured by demodulation equipment. Comparison with the reference temperature, the relative measurement error measured by the developed algorithm and BOTDA are within 4% and 8%, respectively.


Sign in / Sign up

Export Citation Format

Share Document