scholarly journals Solution refractive index sensor with wide-range high-resolution linear response based on short no-core fiber

2013 ◽  
Vol 62 (15) ◽  
pp. 150703
Author(s):  
Zheng Jing-Jing ◽  
Jian Shui-Sheng ◽  
Ma Lin ◽  
Bai Yun-Long ◽  
Pei Li ◽  
...  
2021 ◽  
Author(s):  
Zhen Tian ◽  
Lina Suo ◽  
Nan-Kuang Chen ◽  
Yicun Yao ◽  
Liqiang Zhang ◽  
...  

2018 ◽  
Vol 46 ◽  
pp. 302-305 ◽  
Author(s):  
Bowen Wang ◽  
Kai Ni ◽  
Piaopiao Wang ◽  
Qifei Ma ◽  
Weijian Tian ◽  
...  

Nanomaterials ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 2097
Author(s):  
Yuan-Fong Chou Chau ◽  
Chung-Ting Chou Chao ◽  
Siti Zubaidah Binti Haji Jumat ◽  
Muhammad Raziq Rahimi Kooh ◽  
Roshan Thotagamuge ◽  
...  

This work proposed a multiple mode Fano resonance-based refractive index sensor with high sensitivity that is a rarely investigated structure. The designed device consists of a metal–insulator–metal (MIM) waveguide with two rectangular stubs side-coupled with an elliptical resonator embedded with an air path in the resonator and several metal defects set in the bus waveguide. We systematically studied three types of sensor structures employing the finite element method. Results show that the surface plasmon mode’s splitting is affected by the geometry of the sensor. We found that the transmittance dips and peaks can dramatically change by adding the dual air stubs, and the light–matter interaction can effectively enhance by embedding an air path in the resonator and the metal defects in the bus waveguide. The double air stubs and an air path contribute to the cavity plasmon resonance, and the metal defects facilitate the gap plasmon resonance in the proposed plasmonic sensor, resulting in remarkable characteristics compared with those of plasmonic sensors. The high sensitivity of 2600 nm/RIU and 1200 nm/RIU can simultaneously achieve in mode 1 and mode 2 of the proposed type 3 structure, which considerably raises the sensitivity by 216.67% for mode 1 and 133.33% for mode 2 compared to its regular counterpart, i.e., type 2 structure. The designed sensing structure can detect the material’s refractive index in a wide range of gas, liquids, and biomaterials (e.g., hemoglobin concentration).


2021 ◽  
pp. 1-1
Author(s):  
Guangying Wang ◽  
Baoliang Liao ◽  
Yuan Cao ◽  
Tuan Guo ◽  
Xinhuan Feng ◽  
...  

2019 ◽  
Vol 453 ◽  
pp. 124356 ◽  
Author(s):  
Min Shao ◽  
Liang Han ◽  
Haonan Sun ◽  
Xunli Yin ◽  
Xueguang Qiao

2012 ◽  
Author(s):  
Xiaozhong Tian ◽  
Chunying Guan ◽  
Hailong Wu ◽  
Libo Yuan

Sensors ◽  
2019 ◽  
Vol 19 (19) ◽  
pp. 4210 ◽  
Author(s):  
Pathak ◽  
Rahman ◽  
Singh ◽  
Kumari

In the present paper, a new kind of concave shaped refractive index sensor (CSRIS) exploiting localized surface plasmon resonance (LSPR) is proposed and numerically optimized. The LSPR effect between polaritons and the core guided mode of designed CSRIS is used to enhance the sensing performance. The sensor is characterized for two types of sensing structures coated with gold (Au) film and Au nanowires (AuNWs), respectively. The influence of structural parameters such as the distance (D) of the concave shaped channel (CSC) from the core, the diameter of the nanowire (dn) and the size (s) of the CSC are investigated here. In comparison to Au film, the AuNWs are shown to significantly enhance the sensitivity and the performance of the designed sensor. An enhanced sensitivity of 4471 nm/RIU (refractive index unit) is obtained with AuNWs, for a wide range of analytes refractive index (na) varying between 1.33 to 1.38. However, for conventional Au film; the sensitivity of 808.57 nm/RIU is obtained for the same range of analytes.


Sign in / Sign up

Export Citation Format

Share Document