scholarly journals Numerical simulation of the near-field distribution of light spot of aperture pyramid-type optical probe with a metal tip

2010 ◽  
Vol 59 (1) ◽  
pp. 192
Author(s):  
Wang Guo-Jun ◽  
Wu Shi-Fa ◽  
Li Xu-Feng ◽  
Li Rui ◽  
Duan Jian-Min ◽  
...  
2005 ◽  
Vol 97 (10) ◽  
pp. 104322 ◽  
Author(s):  
L. Aigouy ◽  
M. Mortier ◽  
J. Giérak ◽  
E. Bourhis ◽  
Y. De Wilde ◽  
...  

2014 ◽  
Vol 1044-1045 ◽  
pp. 1362-1365
Author(s):  
Yan Feng Liu ◽  
Bing Wei

The near-field characteristics of the ideal electric dipole are analyzed in this paper. A practical ultrafast band antenna near field FDTD is made and the near field distribution of the antenna is studied by numerical simulation. The calculation results show that the FDTD method is used for the analysis of feasibility and reliability of the near-field communication antenna.


2018 ◽  
Vol 2019 (10) ◽  
Author(s):  
Y.A. Amchislavskiy ◽  
◽  
I.M. Kuptsov ◽  
E.V. Bulychev ◽  
N.L. Menshikh ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Zhirayr Baghdasaryan ◽  
Arsen Babajanyan ◽  
Levon Odabashyan ◽  
Jung-Ha Lee ◽  
Barry Friedman ◽  
...  

AbstractIn this study, a new optical method is presented to determine the concentrations of NaCl and glucose aqueous solutions by using a thermo-elastic optical indicator microscope. By measuring the microwave near-field distribution intensity, concentration changes of NaCl and glucose aqueous solutions were detected in the 0–100 mg/ml range, when exposed to microwave irradiation at 12 GHz frequency. Microwave near-field distribution intensity decreased as the NaCl or glucose concentration increased due to the changes of the absorption properties of aqueous solution. This method provides a novel approach for monitoring NaCl and glucose in biological liquids by using a CCD sensor capable of visualizing NaCl and glucose concentrations without scanning.


2021 ◽  
Vol 2021 (8) ◽  
Author(s):  
L.A. Bokeria ◽  
◽  
T.T. Kakuchaya ◽  
A.M. Kuular ◽  
Ye.S. Maksimovitch ◽  
...  

Results of theoretical and experimental studies of the method of the near-field microwave tomography of the thorax are presented. Integral equations of inverse tomography problem of 3D blood- and air content inhomogeneities by data of multisensory measurements are obtained. Methods of air and blood content profiling in processes of breathing and heart activity by data of bistatic measurements of the scattered signal are proposed and solving algorithms of inverse problems are studied in the numerical simulation. Multifrequency and pulse measurements of scattered signals are carried out in processes of cardiorespiratory activity. By data of bistatic measurements of scattered signals parameters from the thorax, profiling relative air- and blood content profiles has been realized. Application possibilities of the method in the biomedical diagnostics are considered.


Sign in / Sign up

Export Citation Format

Share Document