scholarly journals Development and validation of UPLC method for simultaneous estimation of Efavirenz and Lamivudine in pharmaceutical formulations

Author(s):  
Madhusudhanareddy Induri ◽  
Bhagavan Mantripragada ◽  
Rajendra Yejella
INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (08) ◽  
pp. 54-61
Author(s):  
B. Venkateswara Rao ◽  
◽  
S. Vidyadhara ◽  
V. Basaveswara Rao

The prime aim of the present investigation was to develop and validate a novel, precise, accurate, specific, rapid and economical stability- indicating isocratic reverse phase liquid chromatography method for the quantitative simultaneous estimation of valsartan and hydrochlorothiazide in bulk and marketed formulations. Estimation of drugs in this combination was achieved with a C18 column [Kromasil 100-5 C18 column, P134 250 × 4.6 mm] kept at ambient temperature, isocratic mode using mobile phase of composition acetonitrile and phosphate buffer (40:60 V/V, pH 4). The flow rate was 0.8 ml/min and the effluents were monitored at 235 nm, using variable wavelength UV detector. The retention time of valsartan and hydrochlorothiazide were 2.65 min and 3.97 min, respectively. Validation of the method was done according to the ICH guidelines for different analytical parameters. The method was found to be linear over a range of 50-250 μg/mL for valsartan and hydrochlorothiazide. The established method was as reproducible with a %RSD value of less than 2 and having robustness and accuracy within the specified limits. Assay of marketed formulation was determined and was 99.04% and 99.8% respectively. The stressed samples were analyzed. The proposed method was found to be specific and stability indicating as no interfering peaks of degradation compounds and excipients were noticed. The proposed method can be successfully employed in the estimation of commercial formulations.


2019 ◽  
Vol 9 (01) ◽  
pp. 83-88
Author(s):  
Pinkal Patel ◽  
Nalini Patel ◽  
Kinjal Parmar

A simple, selective and rapid reversed phase High Performance Liquid Chromatographic (RP-HPLC) method has been developed and validated for the simultaneous analysis Gatifloxacin and flurbiprofen sodium in eye drops. The separation was carried out using a mobile phase consisting ACN: Buffer (pH 3.5) in the ratio of 55:45 v/v. The column used was Phenomenex luna ODS C18 (250mm X 4.6 mm i.d., 5 μm particle size) with flow rate of 1 ml / min using UV detection at 268 nm. The described method was linear over a concentration range of 2-12 μg/ml for both of Gatifloxacin and flurbiprofen sodium. The retention times of Gatifloxacin and flurbiprofen sodium were found to be 3.710 min. and 6.797 min respectively. Method was validated statistically and recovery studies were carried out. The proposed method has been applied successfully to the analysis of cited drugs either in pure form or in pharmaceutical formulations with good accuracy and precision. The method here in described can be employed for quality control and routine analysis of drugs in pharmaceutical formulations.


Author(s):  
Poojari Venkatesh ◽  
Umasankar Kulandaivelu ◽  
Gsn Koteswara Rao ◽  
Guntupalli Chakravarthi ◽  
Rajasekhar Reddy Alavala ◽  
...  

Aim: To develop a stability indicating Rp-UPLC method for the simultaneous determination of Lamivudine, Dolutegravir and their degradants in tablets. Methodology: The chromatographic separation was performed on BEH Shield RP18 (2.1 mmX100 mmX1.7 mm) using a isocratic mobile phase Potassium dihydrogen orthophosphate pH 3 adjusted with orthophosphoric acid: methanol (30:70,% v/v) at a flow rate of 0.5ml/min. Column was maintained at room temperature and eluents are monitored at 258 nm. Results: Retention times of the analytes were found to be at 0.81 and 2.78 mins for Lamivudine and Dolutegravir respectively. The calibration of peak area versus concentration, which was linear from 105 to 315 µg/ml for Lamivudine and 17.5 to 52.5 µg/ml for Dolutegravir, had regression coefficient (r2) greater than 0.999. The method had the requisite accuracy, precision and robustness for simultaneous determination of Lamivudine and Dolutegravir in tablets. Conclusion: The proposed method is simple, economical, accurate, precise and can be successfully employed in routine quality control for the simultaneous analysis of Lamivudine and Dolutegravir in pharmaceutical formulations.


2017 ◽  
Vol 5 (01) ◽  
pp. 48-50
Author(s):  
Uttam Kumar Agrawal ◽  
Jeyabalan Govindasamy

A new simple, accurate ,precise and reproducible RP-HPLC method has been developed for simultaneous estimation of metformin and pioglitazone in bulk drug form using proper HPLC system. The mobile phase consists of phosphate buffer and acetonitrile in the ratio of 35:65 at pH 3.4.The detection wavelength was carried out at 228 nm. The method was linear over the concentration range for metformin 50-100 μg/mL and for pioglitazone 20-180 μg/mL. The recoveries of metformin and pioglitazone were found to be 100.5 and 98.7% respectively. The validation of method was carried out utilizing ICH-guidelines. The described HPLC method method was successfully for the analysis of pharmaceutical formulations containing dosage form.


Author(s):  
E. Amulya ◽  
N. Naveen Kumar ◽  
CH. Mounika ◽  
V. Kowmudi ◽  
N. Supriya ◽  
...  

A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of Trihexyphenidyl and Haloperidol, in its pure form as well as in tablet dosage form. Chromatography was carried out on a Altima C18 (4.6 x 150mm, 5μm) column using a mixture of Methanol: TEA Buffer pH 4.5: Acetonitrile (50:25:25) as the mobile phase at a flow rate of 1.0ml/min, the detection was carried out at 225 nm. The retention time of the Trihexyphenidyl and Haloperidol was 2.102, 3.537±0.02min respectively. The method produce linear responses in the concentration range of 15-75ppm of Trihexyphenidyland 37.5-187.5ppm of Haloperidol. The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of pharmaceutical formulations.


Author(s):  
Sayma Khader ◽  
Ayesha Begum K ◽  
D. Ramakrishna

A new, reliable, and validated reverse phase-high-performance liquid chromatography (HPLC) method was developed to quantify the amount of allopurinol and lesinurad simultaneously in solid (tablet) dosage form. A clear chromatographic division was attained on inertsil ODS (4.6 x 250 mm, 5 mm) column, and a mixture of 0.1% trifluoroacetic acid and methanol in the ratio of 40:60 v/v was used as mobile phase. The rate of flow was set at 1 mL/min, and UV detection was achieved at λmax of 255 nm. Injection volume was set to 20 μL. The correlation coefficient of 0.999 was established, and the accurateness was found to be 100.69 and 100.49 for both the drugs, respectively. Therefore, the developed method was simple, specific, precise, and stable. Hence, the method can be employed to estimate the said drugs in other pharmaceutical formulations.


Sign in / Sign up

Export Citation Format

Share Document