Electronic Stethoscope using PVDF Sensor for Wireless Transmission of Heart and Lung Sounds

Author(s):  
Jae Joong Im ◽  
Young Chul Lim
Data in Brief ◽  
2021 ◽  
pp. 106913
Author(s):  
Mohammad Fraiwan ◽  
Luay Fraiwan ◽  
Basheer Khassawneh ◽  
Ali Ibnian

2018 ◽  
Vol 94 (1118) ◽  
pp. 700-703
Author(s):  
Eric R. Gottlieb ◽  
Jason M. Aliotta ◽  
Dominick Tammaro

BackgroundElectronic stethoscopes are becoming more common in clinical practice. They may improve the accuracy and efficiency of pulmonary auscultation, but the data to support their benefit are limited.ObjectiveTo determine how auscultation with an electronic stethoscope may affect clinical decision making.MethodsAn online module consisting of six fictional ambulatory cases was developed. Each case included a brief history and lung sounds recorded with an analogue and electronic stethoscope. Internal medicine resident participants were randomly selected to hear either the analogue or electronic lung sounds. Numbers of correct answers, time spent on each case and numbers of times the recordings were played were compared between the groups who heard each mode of auscultation, with a p value of less than 0.05 indicating statistical significance.Results61 internal medicine residents completed at least one case, and 41 residents completed all six cases. There were no significant differences in overall scores between participants who heard analogue and electronic lung sounds (3.14±0.10 out of 6 correct for analogue, 3.20±0.10 out of 6 for electronic, p=0.74). There were no significant differences in performance for any of the six cases (p=0.78), time spent on the cases (p=0.67) or numbers of times the recordings were played (p=0.85).ConclusionWhen lung sounds were amplified with an electronic stethoscope, we did not detect an effect on performance, time spent on the cases or numbers of times participants listened to the recordings.


2019 ◽  
Vol 8 (3) ◽  
pp. 2731-2735

The investigations from recent studies clearly show the potential of lung sounds in detection of lung abnormalities in human subjects. This paper aims to analyze lung sounds acquired using special electronic stethoscope for detection adventitious sounds arising out of pathological lungs due to various disease like brochities especially in pediatric population. For acquisition and recording of lung sounds, 3M Littmann 3200 model is utilized. After verifying fidelity of electronic stethoscope, the analysis of lung sounds was carried out by various spectral and temporal features. The features extracted were fed to artificial neural network for classification. Various combinations of ANN with different topologies were experimented. The overall accuracy of obtained with one hidden layer GFF is 94.95%.


2020 ◽  
Author(s):  
Takanobu Hirosawa ◽  
Yukinori Harada ◽  
Kohei Ikenoya ◽  
Shintaro Kakimoto ◽  
Yuki Aizawa ◽  
...  

BACKGROUND The urgent need for telemedicine has become clear situation in the pandemic of the coronavirus disease 2019. To facilitate telemedicine, the development and improvement of remote examination systems are required. A system combining an electronic stethoscope and Bluetooth connectivity is a promising option for remote auscultation in clinics and hospitals. However, the utility of such systems remains unknown. OBJECTIVE This study was conducted to assess the utility of real-time auscultation, using a Bluetooth-connected electronic stethoscope compared to that of classical auscultation, using a lung simulator. METHODS This was an open-label randomized controlled trial, including senior residents and faculty in the department of general internal medicine of a university hospital. The only exclusion criterion was a refusal to participate. All participants attended a tutorial session, in which they listened to 15 lung sounds on the lung simulator using a classic stethoscope and were told the correct classification. Thereafter, participants were randomly assigned to either the real-time remote auscultation group (intervention group) or the classical auscultation group (control group), for test sessions. In the test sessions, participants had to classify a series of ten lung sounds. The intervention group listened to the lung sounds remotely, using the electronic stethoscope, a Bluetooth transmitter, and a wireless, noise-canceling, stereo headset. The control group listened to the lung sounds directly using a traditional stethoscope. The primary outcome was the test score, and the secondary outcomes were the rates of correct answers for each lung sound. The two groups were compared using the Fisher exact test. RESULTS In total, 20 participants were included; eleven and nine were assigned to the intervention and control groups, respectively. There was no difference in age (P=.25), sex (P=.82), and years from graduation (P=.15) between the two groups. The overall test score in the intervention group (80/110, 72.7%) was not different from that in the control group (71/90, 78.9%) (P=.32). The only lung sound for which the correct answer rate differed between groups was that of pleural friction rubs (P=.03); it was lower in the intervention group (3/11, 27%) than in the control group (7/9, 78%,). CONCLUSIONS The utility of a real-time remote auscultation system using a Bluetooth-connected electronic stethoscope was comparable to that of direct auscultation using a classic stethoscope, except for classification of pleural friction rubs. CLINICALTRIAL UMIN-CTR UMIN000040828; https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000046222.


2019 ◽  
Vol 9 (01) ◽  
pp. 47-54
Author(s):  
Rabbai San Arif ◽  
Yuli Fitrisia ◽  
Agus Urip Ari Wibowo

Voice over Internet Protocol (VoIP) is a telecommunications technology that is able to pass the communication service in Internet Protocol networks so as to allow communicating between users in an IP network. However VoIP technology still has weakness in the Quality of Service (QoS). VOPI weaknesses is affected by the selection of the physical servers used. In this research, VoIP is configured on Linux operating system with Asterisk as VoIP application server and integrated on a Raspberry Pi by using wired and wireless network as the transmission medium. Because of depletion of IPv4 capacity that can be used on the network, it needs to be applied to VoIP system using the IPv6 network protocol with supports devices. The test results by using a wired transmission medium that has obtained are the average delay is 117.851 ms, jitter is 5.796 ms, packet loss is 0.38%, throughput is 962.861 kbps, 8.33% of CPU usage and 59.33% of memory usage. The analysis shows that the wired transmission media is better than the wireless transmission media and wireless-wired.