scholarly journals Modified everting sutures combined with reattachment to the inferior tarsal plate for involutional lower eyelid entropion: A new technique

2020 ◽  
Vol 47 (4) ◽  
pp. 347-353
Author(s):  
Emine Malkoc Sen ◽  
Kubra Ozdemir Yalcinsoy

Background This study evaluated the outcomes of a new modified Wies technique for patients with involutional lower eyelid entropion without horizontal eyelid laxity.Methods This case series retrospectively analyzed consecutive patients with entropion who underwent surgery between January 2014 and March 2019 by the same experienced surgeon. Horizontal eyelid laxity, lower eyelid retractor function, and orbicularis muscle overriding were recorded before and after surgery. The recurrence rate and complications were also evaluated. This technique consisted of modified everting sutures combined with reattachment of the lower eyelid retractors to the inferior tarsal plate.Results This new technique was performed on 28 eyes in 25 patients (mean age, 71.0±8.0 years; range, 56–87 years). Nine patients (36%) were women and 16 (64%) were men. Lower lid entropion was present in the right eye in 14 patients (56%), the left eye in eight patients (32%), and both eyes in three patients (12%). The mean follow-up period was 27.3±12.4 months (range, 6–60 months). No intraoperative complications were observed. All patients’ symptoms were alleviated. One patient (3.6%) had recurrence after 2 years (success rate, 96.4%). The remaining 27 eyes maintained a satisfactory and comfortable eyelid position. No patients had problems with scarring.Conclusions The approach described herein proved to be safe and feasible in eyes with involutional lower eyelid entropion without horizontal eyelid laxity. These advantages of this procedure include the lack of a conjunctival scar, punctal eversion, and lateral canthal angle deformation. A low recurrence rate and a long interval to recurrence were also observed.

2021 ◽  
pp. 112067212199574
Author(s):  
Abbas Bagheri ◽  
Mohadeseh Feizi ◽  
Ramin Sahebghalam ◽  
Mehdi Tavakoli

Purpose: To report the effect of lower eyelid temporalis fascia sling combined with lateral canthoplasty and tarsorrhaphy for paralytic ectropion. Methods: Prospective case series of 10 patients with lower lid paralytic ectropion who were treated with lower eyelid fascia temporalis sling and lateral canthoplasty in addition to lateral tarsorrhaphy as a single-session procedure. Additional medial tarsorrhaphy was applied if the medial lower lid apposition was not adequate at the end of the procedures. Eyelid configuration and function were compared before and after surgery. Results: The mean age of patients was 65.8 ± 10 years. Mean marginal reflex distance 1 (MRD1) and MRD2 changed from 3.5 ± 1.4 and 8.6 ± 2.4 mm to 2.2 ± 1.4 and 5.3 ± 1.2 mm respectively ( p = 0.001 and 0.006). Mean pre-operative lagophthalmos improved from 9.2 ± 4.9 to 3.4 ± 1.3 mm ( p = 0.001). The mean follow-up was 28.9 ± 12.1 months. Three patients required additional medial tarsorrhaphy to address residual medial ectropion in the same session. Conclusion: Combination of lower lid fascia temporalis sling, lateral canthoplasty and tarsorrhaphy as a single-session procedure can effectively improve the functional and aesthetic complications of paralytic ectropion.


Author(s):  
Marcos Augusto Tomazi ◽  
Alexandre da Silveira Gerzson ◽  
Angelo Menuci Neto ◽  
André Luciano Pasinato da Costa

The edentulous atrophic posterior mandible is often a great challenge for implant rehabilitation. Although a number of treatment options have been proposed, including the use of short implants and surgical grafting techniques, in cases of severe bone atrophy, techniques for mobilization of the inferior alveolar nerve (IAN) have been shown to be efficient, with good results. Four female patients underwent IAN lateralization for prosthetic rehabilitation of the posterior mandible from 2013 to 2019, with 1 year to 5 years and 4 months of follow-up. This case series describes a new technique for mobilization of the IAN, named in-block lateralization, to facilitate access to the IAN and to reduce nerve manipulation. The implant is immediately installed (allowing nerve lateralization in unitary spaces) and the original mandibular anatomy is restored with autogenous bone from the original bed during the same surgical procedure. When well indicated and well performed, this new approach provides better and easier visualization of the IAN as well as safer manipulation aiming to achieve good results for implant stability and minimal risk of neurosensory disturbances, allowing rehabilitation even in unitary spaces.


2012 ◽  
Vol 102 (3) ◽  
pp. 198-204
Author(s):  
J.-Young Kim

Background: Severely incurved toenails are accompanied by deformity of the toenail growth plate. In such a condition, partial removal of the nail and nail bed and simple unfolding of the nail itself frequently result in the recurrence of symptoms. We sought to design and develop a new technique for the treatment of incurved toenail with growth plate deformity and to report the results of treating this disease entity. Methods: Forty consecutive patients (52 cases) underwent treatment of symptomatic incurved toenails with a new technique named matrixplasty. The mean ± SD patient age was 40.3 ± 18.9 years. Last follow-up was at a mean ± SD of 18.0 ± 1.3 months. An American Orthopedic Foot and Ankle Society (AOFAS) forefoot hallux score was assigned, and patients were evaluated before treatment and at last follow-up. Patient satisfaction and the recurrence rate of the deformity were evaluated. For evaluation of improvement in toenail shape, the center to edge angle of the toenail was measured before treatment and at last follow-up. The complication rate was also evaluated. Results: All of the ingrown toenails healed, and the nail deformities were corrected within 3 weeks after the procedure. None of the incurved toenails had recurred by last follow-up. The mean pretreatment AOFAS forefoot hallux score was 72.9, and it improved to 99.6 by last follow-up (P < .001). Every patient was very satisfied or satisfied with the results of treatment. The mean ± SD center to edge angle of the toenail improved from 53.3° ± 9.5° to 15.3° ± 5.2° by last follow-up (P < .001). Minor paronychia, which was managed with local wound dressing and oral antibiotics, was identified in four cases. No other complication was identified. Conclusions: Matrixplasty showed excellent clinical results in the treatment of severe incurved toenail, and this newly developed procedure showed improvement of the deformed toenail and its growth plate. (J Am Podiatr Med Assoc 102(3): 198–204, 2012)


2013 ◽  
Vol 6 (2) ◽  
pp. 125-130
Author(s):  
Danelina E. Vacheva ◽  
Verjinia K. Simeonova ◽  
Boyko St. Stamenov

Summary Bulgaria ranks first in the world in incidence, morbidity and death associated with cerebrovascular disease. The aim of the study was to investigate, follow-up and register recovery of activities of daily living (using the toilet and maintaining personal hygiene) in patients with sequelae from cerebrovascular disease in a subacute stage, who underwent physiotherapy and rehabilitation. Sixty-one patients were included and followed up. They were given tailored physiotherapy and rehabilitation. This included kinesitherapy, occupational therapy and electrotherapy. All the patients filled in self-assessment questionnaires before and after the rehabilitation course. Major parameters were assessed, irrespective of the limb affected -dominant or non-dominant. Results were analyzed using the Wilcoxon rank test. At the end of the rehabilitation course, the Wilcoxon curves were driven to the right, confirming improvement concerning independence, irrespective of involvement of dominant or non-dominant limb.


2021 ◽  
Vol 8 (6) ◽  
pp. 22-30
Author(s):  
Vincenzo Foti ◽  
Davide Savio ◽  
Roberto Rossi

The aim of this case series is to introduce the One-Time Cortical Lamina Technique, a simplification of the F.I.R.S.T. (Fibrinogen-Induced Regeneration Sealing Technique) in cases where only horizontal augmentation is needed. The indications for this technique are ASA2 and ASA1 anxious patients. Pre-requisites for this surgical technique are: a good amount of keratinized tissue, sufficient alveolar ridge width for placement of implants, thickness of vestibular bone at CBCT planning less than 1 mm with risk of threads exposure. Five patients with horizontal deficiencies were selected to test the efficacy of this approach. The defects were augmented using a porcine cortical bone lamina in combination with collagenated porcine bone mixed with fibrin sealant. The cortical lamina was placed only buccal to the implants and stabilized with fibrin sealant, without pins or screws. Upon completion of the implant surgery, healing abutments were connected to the implants and the soft tissue sutured around them. The healing was uneventful in all cases. Six months after surgery impressions for final restorations were taken and screwed crowns delivered. The new volume had hard consistency and the follow-up CBCT measured an average of 4.17 mm of horizontal bone augmentation. One to three years of follow up demonstrated the maintenance of vestibular volume, hard consistency and clinical stability. Intraoral X-rays showed no marginal bone loss. An advantage of this technique could be the one stage surgery that creates a stable environment for regeneration from day one.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hyunkyu Lee ◽  
Jimin Youn ◽  
Sehyun Baek

AbstractTo report the experience and advantageous effects of high-frequency radio wave electrocautery in modified Hotz operations for epiblepharon, We reviewed the records of all pediatric patients who underwent a modified Hotz operation with the use of high-frequency radio wave electrocautery (Ellman Surgitron Dual Frequency RF S5; Ellman International, Inc, Hewlett, NY) for epiblepharon between March 2016 and September 2019 at Korea University Guro Hospital. We evaluated the success rate, complications, recurrence rate and degree of satisfaction of our technique. Information from the medical records was collected, including demographics, ocular symptoms, severity of keratopathy, operation time, success/recurrence rate, and complications. 133 patients (98.52%) showed good correction of epiblepharon without complications or unpleasant cosmetic problems during 3 months of median follow-up period. Two patients (1.48%) showed recurrent corneociliary touch, but the degree was very mild and re-operation was not performed. One patient showed mild ectropion on his left lower eyelid, but the patient recovered well without operation. For complications, suture abscess and granulation were the most common, 3 cases in each, but all of those were temporary and resolved with conservative management. The approach with electrocautery for epiblepharon allows precise and fast incision of the lower eyelid, little bleeding, and minimal scarring. Surgical outcomes associated with the modified Hotz operation with electrocautery were consistent with previous studies.


1993 ◽  
Vol 6 (2) ◽  
pp. 74-77
Author(s):  
B. Dean ◽  
Donald R. Coid

Ultrasonography of the hip is a new technique which is said to assist in the diagnosis of neonatal hip disorders. The authors were unaware of any reports of formal evaluation of the introduction of this new technology into a District General Hospital. This study outlines several aspects of patient care before and after the introduction of neonatal hip ultrasonography to a Fife hospital as an adjunct to a neonatal orthopaedic clinic. After introduction of ultrasound the proportion of patients where the consultant was ‘very confident’ in the diagnosis increased by 29% (95% confidence intervals 9% to 49%); the proportion of children requiring three or more x-rays in the year following referral fell by 46% (95% confidence intervals 27% to 65%) and the proportion of children requiring five or more follow up attendances in the year following referral fell by 56% (95% confidence intervals 38% to 74%). Introduction of this technology has benefited patients by reducing their need to attend clinics and reducing their overall exposure to ionising radiation. There is a continuing need for ultrasonography to be provided in Fife neonatal orthopaedic outpatient clinics.


2020 ◽  
Vol 19 (4) ◽  
pp. 422-428
Author(s):  
Kunal Vakharia ◽  
Muhammad Waqas ◽  
Najya Fayyaz ◽  
Amanda Young ◽  
Elad I Levy ◽  
...  

Abstract BACKGROUND Instantaneous wave-free ratios (iFRs) are functional measures of arterial stenosis that have become essential to interventional cardiology procedures. Their use for intracranial submaximal angioplasty (angioplasty with an undersized balloon) has not been studied extensively. OBJECTIVE To describe the feasibility and technique of iFR measurement for stenosis assessment during intracranial angioplasty. METHODS We present a series of consecutive patients treated between January 1, 2017 and June 30, 2018 with submaximal intracranial angioplasty in whom pre- and postprocedure iFR measurements were obtained with a Verrata-Volcano pressure wire (Philips, Amsterdam, The Netherlands). We collected patient data on age, sex, comorbid conditions, presenting complaints, modified Rankin scale (mRS) score at admission, neurological findings, procedure duration, fluoroscopy time, intraprocedural complications, length of hospital stay, and mRS score at last clinical follow-up (favorable outcome, 0-2). Angiographic stenosis severity and iFR values were recorded before and after angioplasty. RESULTS A total of 12 patients underwent iFR-guided angioplasty during the study period. The median patient age was 69.5 yr (range 48-81 yr). All patients had symptomatic intracranial arterial stenosis (3-basilar, 2-vertebral, 6-middle cerebral, 1-internal carotid). Preangioplasty stenosis ranged from 55% to 90%. The median postangioplasty reduction in stenosis was 17% (range 9%-30%). Preangioplasty values ranged from 0.30 to 0.40 (n = 4). Postangioplasty values ranged from 0.6 to 0.9 (n = 5). iFR values improved considerably in all patients. No procedure-related complications occurred. The median follow-up was 8.9 mo (range 3-25 mo). Follow-up outcomes were favorable in 10 patients. CONCLUSION iFR measurement before and after intracranial angioplasty is feasible. It may be used to assess the adequacy of intracranial angioplasty.


Sign in / Sign up

Export Citation Format

Share Document