scholarly journals The influence of the internal ballistic pressure on the rifled barrel stress response

2020 ◽  
Vol 70 (2) ◽  
pp. 41-46
Author(s):  
Abaci Boukera ◽  
Aleksandar Kari ◽  
Damir Jerković ◽  
Nebojša Hristov

This paper focused on the 12.7 mm gun barrel stress response caused by the pressure of the gunpowder gases. During the firing process, the barrel is loaded by different mechanical, chemical and thermal loads. In this paper except the pressure of the propellant combustion, all the other loads were ignored. The pressure loads are obtained with a mathematical model of the interior ballistic. The Lame equations for the thick-walled cylinder were used to calculate the barrel stress response. The loads are applied on a certain barrel cross-section for a defined time. Two 3D models of the barrel with and without grooves were used to perform a numerical simulation. A comparison between results for the two types of barrels shows a good agreement between the stresses obtained by the analytical and numerical methods.

Author(s):  
Mohamed Gadalla ◽  
Muhammad Jasim ◽  
Omar Ahmad

Abstract The thermal stability parameter is an important parameter for predicting the lifespan of structures. In this paper, a two-dimensional transient heat transfer model of machine gun barrels undergoing continuous firing developed and analyzed for different geometries and thermal properties. The model for the transient thermal analysis is based on the forced convection heat transfer at the inner surface of the gun barrel. Finite element simulations were performed to predict the interior and exterior barrel temperature profiles and temperature contours after continuous firing process. The incomplete Cholesky Conjugate Gradient (ICCG) solver was adopted in solving unsymmetrical thermal transient analyses. The material thermal behavior studied for the basic circular cross section of gun barrels showed that the lowest inner wall temperature was for high rounds was achieved in steel barrels due to the rapid conducted and convective heat transfer to the environment. While the highest inner wall temperature was recorded for ceramic STK4 barrels and an increase of inner wall temperature by 17% was observed as compared to the typical case of circular cross section steel barrel. In general, a higher inner temperature in the gun barrel is undesirable and harm due to the possibility of reaching the cook-off scenario at earlier rounds. Results concluded that non-circular geometries with constrained cross section areas of typical case improve thermal management and the hexagonal geometry had the best thermal management and could provide more rounds for users. In addition, titanium barrels would have a weight drop of 41% while the overall barrel’s temperature increases by 49%.


Author(s):  
MousalrezaFaramarzi Palangar ◽  
Mohammad Mirzaie

Abstract—In this paper, an improved mathematical model for flashover behavior of polluted insulators is proposed based on experimental tests. In order to determine the flashover model of polluted insulators, the relationship between conductivity and salinity of solution pollution layer of the insulator is measured. Then, the leakage of current amplitude of four common insulators versus axial, thermal conductivity and arc constants temperature was determined. The experimental tests show that top leakage distance (TLd) to bottom leakage distance (BLd) ratio of insulators has a significant effect on critical voltage and current. Therefore, critical voltage and current were modeled by TLd to BLd ratio Index (M). Also, salinity of solution pollution layer of the insulators has been applied to this model by resistance pollution parameter. On the other hand, arc constants of each insulator in new model have been identified based on experimental results. Finally, a mathematical model is intended for critical voltage against salinity of solution pollution layer of different insulators. This model depends on insulator profile. There is a good agreement between the experimental tests of pollution insulators obtained in the laboratory and values calculated from the mathematical models developed in the present study.


Author(s):  
MousalrezaFaramarzi Palangar ◽  
Mohammad Mirzaie

In this paper, an improved mathematical model for flashover behavior of polluted insulators is proposed based on experimental tests. In order to determine the flashover model of polluted insulators, the relationship between conductivity and salinity of solution pollution layer of the insulator is measured. Then, the leakage of current amplitude of four common insulators versus axial, thermal conductivity and arc constants temperature was determined. The experimental tests show that top leakage distance (TLd) to bottom leakage distance (BLd) ratio of insulators has a significant effect on critical voltage and current. Therefore, critical voltage and current were modeled by TLd to BLd ratio Index (M). Also, salinity of solution pollution layer of the insulators has been applied to this model by resistance pollution parameter. On the other hand, arc constants of each insulator in new model have been identified based on experimental results. Finally, a mathematical model is intended for critical voltage against salinity of solution pollution layer of different insulators. This model depends on insulator profile. There is a good agreement between the experimental tests of pollution insulators obtained in the laboratory and values calculated from the mathematical models developed in the present study.


Author(s):  
MousalrezaFaramarzi Palangar ◽  
Mohammad Mirzaie

In this paper, an improved mathematical model for flashover behavior of polluted insulators is proposed based on experimental tests. In order to determine the flashover model of polluted insulators, the relationship between conductivity and salinity of solution pollution layer of the insulator is measured. Then, the leakage of current amplitude of four common insulators versus axial, thermal conductivity and arc constants temperature was determined. The experimental tests show that top leakage distance (TLd) to bottom leakage distance (BLd) ratio of insulators has a significant effect on critical voltage and current. Therefore, critical voltage and current were modeled by TLd to BLd ratio Index (M). Also, salinity of solution pollution layer of the insulators has been applied to this model by resistance pollution parameter. On the other hand, arc constants of each insulator in new model have been identified based on experimental results. Finally, a mathematical model is intended for critical voltage against salinity of solution pollution layer of different insulators. This model depends on insulator profile. There is a good agreement between the experimental tests of pollution insulators obtained in the laboratory and values calculated from the mathematical models developed in the present study.


Author(s):  
V. Mizuhira ◽  
Y. Futaesaku

Previously we reported that tannic acid is a very effective fixative for proteins including polypeptides. Especially, in the cross section of microtubules, thirteen submits in A-tubule and eleven in B-tubule could be observed very clearly. An elastic fiber could be demonstrated very clearly, as an electron opaque, homogeneous fiber. However, tannic acid did not penetrate into the deep portion of the tissue-block. So we tried Catechin. This shows almost the same chemical natures as that of proteins, as tannic acid. Moreover, we thought that catechin should have two active-reaction sites, one is phenol,and the other is catechole. Catechole site should react with osmium, to make Os- black. Phenol-site should react with peroxidase existing perhydroxide.


Author(s):  
J. P. Colson ◽  
D. H. Reneker

Polyoxymethylene (POM) crystals grow inside trioxane crystals which have been irradiated and heated to a temperature slightly below their melting point. Figure 1 shows a low magnification electron micrograph of a group of such POM crystals. Detailed examination at higher magnification showed that three distinct types of POM crystals grew in a typical sample. The three types of POM crystals were distinguished by the direction that the polymer chain axis in each crystal made with respect to the threefold axis of the trioxane crystal. These polyoxymethylene crystals were described previously.At low magnifications the three types of polymer crystals appeared as slender rods. One type had a hexagonal cross section and the other two types had rectangular cross sections, that is, they were ribbonlike.


2014 ◽  
Vol 541-542 ◽  
pp. 658-662
Author(s):  
Jian Li ◽  
Yuan Chen ◽  
Yang Chun Yu ◽  
Zhu Xin Tian ◽  
Yu Huang

To study the velocity and pressure distribution of the oil film in a heavy hydrostatic thrust bearing, a mathematical model of the velocity is proposed and the finite volume method (FVM) has been used to simulate the flow field under different working conditions. Some pressure experiments were carried out and the results verified the correctness of the simulation. It is concluded that the pressure distribution varies small under different rotation speed when the surface load on the workbench is constant. But the velocity of the oil film is influenced greatly by the rotation speed. When the rotation speed of the workbench is as quick as enough, the velocity of the oil film on one radial side of the pad will be zero, that is to say the lubrication oil will be drained from the other three sides of the recess.


2021 ◽  
Vol 45 (3) ◽  
Author(s):  
C. M. Durnea ◽  
S. Siddiqi ◽  
D. Nazarian ◽  
G. Munneke ◽  
P. M. Sedgwick ◽  
...  

AbstractThe feasibility of rendering three dimensional (3D) pelvic models of vaginal, urethral and paraurethral lesions from 2D MRI has been demonstrated previously. To quantitatively compare 3D models using two different image processing applications: 3D Slicer and OsiriX. Secondary analysis and processing of five MRI scan based image sets from female patients aged 29–43 years old with vaginal or paraurethral lesions. Cross sectional image sets were used to create 3D models of the pelvic structures with 3D Slicer and OsiriX image processing applications. The linear dimensions of the models created using the two different methods were compared using Bland-Altman plots. The comparisons demonstrated good agreement between measurements from the two applications. The two data sets obtained from different image processing methods demonstrated good agreement. Both 3D Slicer and OsiriX can be used interchangeably and produce almost similar results. The clinical role of this investigation modality remains to be further evaluated.


Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 499
Author(s):  
Caroline Bonazza ◽  
Jiao Zhu ◽  
Roger Hasler ◽  
Rosa Mastrogiacomo ◽  
Paolo Pelosi ◽  
...  

An electronic biosensor for odors was assembled by immobilizing the silk moth Bombyx mori pheromone binding protein (BmorPBP1) on a reduced graphene oxide surface of a field-effect transistor. At physiological pH, the sensor detects the B. mori pheromones, bombykol and bombykal, with good affinity and specificity. Among the other odorants tested, only eugenol elicited a strong signal, while terpenoids and other odorants (linalool, geraniol, isoamyl acetate, and 2-isobutyl-3-methoxypyrazine) produced only very weak responses. Parallel binding assays were performed with the same protein and the same ligands, using the common fluorescence approach adopted for similar proteins. The results are in good agreement with the sensor’s responses: bombykol and bombykal, together with eugenol, proved to be strong ligands, while the other compounds showed only poor affinity. When tested at pH 4, the protein failed to bind bombykol both in solution and when immobilized on the sensor. This result further indicates that the BmorPBP1 retains its full activity when immobilized on a surface, including the conformational change observed in acidic conditions. The good agreement between fluorescence assays and sensor responses suggests that ligand-binding assays in solution can be used to screen mutants of a binding protein when selecting the best form to be immobilized on a biosensor.


2021 ◽  
Vol 7 (1) ◽  
pp. 519-539
Author(s):  
Thiago Minete Cardozo ◽  
Costas Papadopoulos

Abstract Museums have been increasingly investing in their digital presence. This became more pressing during the COVID-19 pandemic since heritage institutions had, on the one hand, to temporarily close their doors to visitors while, on the other, find ways to communicate their collections to the public. Virtual tours, revamped websites, and 3D models of cultural artefacts were only a few of the means that museums devised to create alternative ways of digital engagement and counteract the physical and social distancing measures. Although 3D models and collections provide novel ways to interact, visualise, and comprehend the materiality and sensoriality of physical objects, their mediation in digital forms misses essential elements that contribute to (virtual) visitor/user experience. This article explores three-dimensional digitisations of museum artefacts, particularly problematising their aura and authenticity in comparison to their physical counterparts. Building on several studies that have problematised these two concepts, this article establishes an exploratory framework aimed at evaluating the experience of aura and authenticity in 3D digitisations. This exploration allowed us to conclude that even though some aspects of aura and authenticity are intrinsically related to the physicality and materiality of the original, 3D models can still manifest aura and authenticity, as long as a series of parameters, including multimodal contextualisation, interactivity, and affective experiences are facilitated.