Determination of aquifer characteristics in Eket, Akwa Ibom State, Nigeria, using the vertical electrical sounding method

Author(s):  
Magnus Uzoma Igboekwe
2016 ◽  
Vol 4 (1) ◽  
pp. 1 ◽  
Author(s):  
Chika Osele ◽  
Ajana Onwuemesi ◽  
Emmanuel Anakwuba ◽  
Augustine Chinwuko

<p>Surface geo-electrical survey using vertical electrical sounding (VES) method has been carried out in Onitsha and environs in southwestern part of Anambra state in order to determine the aquifer characteristics and groundwater potential of the area. Eleven vertical electrical soundings were carried out within the area of study using schlumberger array configuration. The interpretation of the vertical electrical sounding (VES) data revealed three to five geoelectric units with depth to the aquiferous layers ranging from 21 to 78m and resistivity of the saturated layers varying between 20 and 5600 ohm-m. Aquifer characteristics such as transmissivity and hydraulic conductivity calculated from interpretated VES result ranged from 2.55m2/day to 29.01m2/day and 0.03m/day to 1.37m/day respectively. This result shows that the water saturated sandstone units of the study area is hydrological good and capable of producing optimum groundwater yield. Furthermore, borehole could be drilled at depth between 40 and 110m in the area for sustainable water supply and hydrochemical study carried out to determine the water quality for domestics and municipal purposes.</p>


2016 ◽  
Vol 8 (1) ◽  
Author(s):  
Gulraiz Akhter ◽  
M. Hasan

AbstractIn order to determine the groundwater resources and potentials of the Khanewal District of Pakistan, a geophysical method in combination with pumping test data were used. An analytical relationship between the aquifer parameters interpreted from surface geoelectrical method and pumping test was established in order to estimate aquifer parameters from surface measurements where no pumping tests exist. For the said purpose, 48 geoelectric investigations were carried out using Schlumberger vertical electrical sounding (VES). Seven of the soundings were conducted where pumping tests had been carried out at borehole sites. The vertical electrical sounding stations were interpreted, and resistivities and thickness parameters were calculated. The values of transmissivity and hydraulic conductivity were calculated using the Dar Zarrouk parameter. Transmissivity values obtained from pumping test data and the VES method range between 954 – 4263 m


Sign in / Sign up

Export Citation Format

Share Document