scholarly journals Efficacy of 23-Gauge Pars Plana Vitrectomy with Intraocular SF6 Gas Tamponade for the Treatment of Intraocular Foreign Body

2018 ◽  
Vol In Press (In Press) ◽  
Author(s):  
Hamidreza Torabi
2020 ◽  
Vol 76 (1) ◽  
pp. 14-23
Author(s):  
Štěpán Rusňák ◽  
Lenka Hecová

Purpose: Penetrating eye trauma with an intraocular foreign body is very frequent, especially in men in their productive age. Pars plana vitrectomy would be the standard surgical method at our department. However, in indicated cases (metallic intraocular bodies in the posterior eye segment in young patients with well transparent ocular media without detached ZSM and without any evident vitreoretinal traction) transscleral extraction of the intraocular foreign body is performed using the exo magnet, eventually endo magnet with a minimal PPV without PVD induction under the visual control of endo-illumination. Materials and Methods: Between June 2003 and June 2018, 66 eyes of 66 patients diagnosed with a penetrating eye trauma caused by an intraocular foreign body located in the posterior eye segment were treated. In 18 eyes (27,3 %) with a metallic foreign body in vitreous (body) or in retina, no PPV or a minimal PPV without PVD was used as a surgical method. In the remaining 48 eyes (72,7 %), a standard 20G, respectively 23G PPV method were used together with PVD induction and the foreign body extraction via endo or exo magnet. Conclusions: As demonstrated by our survey/study, in the cases of a thoroughly considered indication an experimented vitreoretinal surgeon can perform a safe NCT transscleral extraction from the posterior eye segment via exo magnet, eventually endo magnet under the visual control of a contact display system with a minimal PPV. Thereby, the surgeon can enhance the patient´s chance to preserve their own lens and its accommodative abilities as well as reduce the risk of further surgical interventions of the afflicted eye.


Retina ◽  
2015 ◽  
Vol 35 (9) ◽  
pp. 1836-1843 ◽  
Author(s):  
Marta S. Figueroa ◽  
JosÉ M. Ruiz-Moreno ◽  
Fernando Gonzalez del Valle ◽  
Andrea Govetto ◽  
Concepción de la Vega ◽  
...  

2017 ◽  
Vol 2017 ◽  
pp. 1-5 ◽  
Author(s):  
Robert Rejdak ◽  
Tomasz Choragiewicz ◽  
Joanna Moneta-Wielgos ◽  
Dominika Wrzesinska ◽  
Dorota Borowicz ◽  
...  

Purpose.To evaluate visual and safety outcomes of 23-gauge (G) pars plana vitrectomy (PPV) with application of perfluorocarbon liquid (PFCL) for intraoperative protection of the macula during intraocular foreign body (IOFB) removal.Methods.Retrospective study of 42 patients who underwent 23 G PPV for IOFB removal from posterior segment with intraoperative PFCL application for the macula shielding. Collected data included corrected distance visual acuity (CDVA), size of IOFB, and complication rate. The mean follow-up period was 12 months.Results. The mean preoperative CDVA was 0.54 logMAR (SD 0.46), and the final mean CDVA was 0.68 logMAR (SD 0.66). All IOFBs were metallic with mean dimensions of 4.6 mm × 2.1 mm. Twenty-two IOFBs were removed through the corneal tunnel and 20 IOFBs through the sclerotomy. No intraoperative iatrogenic lesion of the macula was observed. As a tamponade, silicon oil was applied in 31 eyes, SF6gas in 5 eyes, air in 4 eyes, and 2 eyes required no tamponade. Secondary retinal detachment was observed in 17% of cases, but at the end of the follow-up, all the retinas were attached.Conclusion. PFCL application during PPV is a safe method of protecting the macula from unexpected falling of the metallic IOFB during its removal.


2020 ◽  
Vol 58 (226) ◽  
Author(s):  
Lily Rajbanshi ◽  
Archana Kumari ◽  
Sanjay Singh

Firecracker induced open globe injury is a big challenge for ophthalmic surgeons. Its associationwith the intraocular foreign body makes the diagnosis and treatment even more difficult resultingin poor anatomical and visual outcomes. We report a case of a 35-year-old male who presented withbilateral, multiple corneal and intraocular foreign body due to firecracker explosion. His vision waslimited to hand movement in both eyes. Combined penetrating keratoplasty and cataract surgerywere done in both eyes followed by pars plana vitrectomy for intraocular foreign body removal.The final best-corrected visual acuity of the patient stood to be 6/6 and 6/9 in the right and left eyerespectively. The encouraging result in our case prompts ophthalmologists for a timely stepwisemultidisciplinary approach in all open globe injuries with intraocular foreign body cases havingpoor initial acuity.


2021 ◽  
Vol 13 (1) ◽  
pp. 22-30
Author(s):  
Bikram Bahadur Thapa ◽  
Sweta Singh ◽  
Gyanendra Lamichhane ◽  
Shanti Gurung ◽  
Saurav Piya

Introduction: Posterior segment retained Intraocular foreign body (IOFB) management is challenging. Facility of pars plana vitrectomy (PPV) and availability of well trained vitreo retina surgeons are the basic need to accomplish this work.  Encircling band provide permanent 360° support to close the anterior retinal break and prevent traction on the retina. The objective of this study is to analyse the clinical characteristics and predictors of the final visual outcome and survival of the globe in cases of retained IOFB in the posterior eye segment. Materials and methods: A hospital based retrospective observational study was conducted. All the patients of retained IOFB in the posterior segment presented from January 2016 to June 2019 were enrolled. Patients presented with visual acuity of NPL were excluded. Statistical analysis was performed using a variety of tests using SPSS version 21.   Results: Forty eyes of 40 patients were included. The mean age was 27.08±10.68 years (range 5-66). 95% of our patients were male. Most of them (52.5%) worked on the farm. 26(65%) of 40 eyes had Zone I injury. The median time spent before presentation was 13.5 day. Retinal detachment, vitreous hemorrhage, and endophthalmitis were present in 15, 23 and 5 eyes, respectively, before IOFB removal. The mean LogMAR visual acuity was improved significantly from 2.50±0.87 to 1.33± 1.01 (p=0.003). Poor presenting visual acuity, retinal detachment and large diameter of IOFB were found as the predictor of poor final visual acuity. Conclusion:  Pars plana vitrectomy by a vitreo retinal surgeon can give encouraging results in the cases of retained posterior segment IOFB. Poor presenting visual acuity, large diameter of IOFB and RD before IOFB removal are predictors of poor visual outcome.


2021 ◽  
Vol 3 (2) ◽  
pp. 120-126
Author(s):  
Hui Wen Lim ◽  
Suyi Siow ◽  
Kiet Phang Ling

Traumatic ocular injury is an uncommon yet leading cause of monocular blindness among the working-age group. Retained intraocular foreign body (IOFB) are associated with 41% of open globe injuries. Pars plana vitrectomy is often required for posterior segment IOFB removal. Advances in vitreoretinal surgical techniques and instrumentation have resulted in better treatment outcomes with reduced ocular morbidity. We report a case of modified ILM forceps with perfluorocarbon liquid-assisted non-magnetic IOFB removal in a young man after a motor vehicle accident with zone one open globe injury and a large glass IOFB in the right eye. We describe the use of perfluoro-N-octane to slide the IOFB extramacularly and reorient the IOFB plane for stable and safe retrieval by ILM end-gripping forceps. The modified design of the ILM end-gripping forceps with adjunctive use of perfluorocarbon liquid in pars plana vitrectomy reduces slippage during IOFB extraction and prevents collateral iatrogenic retinal injury.


Sign in / Sign up

Export Citation Format

Share Document