scholarly journals Healthy Aging Guided by Circadian Rhythm Monitoring Using a Smartwatch-Like Device

2021 ◽  
Vol 8 (3) ◽  
Author(s):  
Adriano Barreto Nogueira ◽  
Manoel Teixeira

: Aging is the main factor for onset of disease. Nonetheless, chronological age does not necessarily correspond to biological age. The regulation of aging, circadian rhythms, and temperature involves the same brain structure: the hypothalamus. We previously showed that the analysis of the circadian rhythm of temperature may predict neurologic signs with 24 hours of antecedence. Our hypothesis is that the circadian rhythm of temperature changes gradually with aging and correlates with biological age. This study aims to assess whether the circadian rhythm of temperature correlates with the chronological age of healthy individuals aged between 18 and 72 years and changes more intensely in individuals with obesity, which is a disease associated with unhealthy aging. To achieve the study goals, 60 individuals will be enrolled and separated into four groups according to age (< or ≥ 45 years) and health status (healthy or obese). The participants will wear a wristband with vital sign sensors and an accelerometer for three days to detect movement during wake period and lack of movement during sleep period. The ratio between the mean skin temperature during the sleep and preceding wake period will be the main parameter to be analyzed in the study. The possible result is that this ratio is higher in healthy young individuals, as well as healthy age-matched individuals. This could imply the discovery of a simple and non-invasive method related to the biological age that could guide the prevention and treatment of aging-related diseases.

Author(s):  
Patrick Veit-Haibach ◽  
Martin W. Huellner ◽  
Martin Banyai ◽  
Sebastian Mafeld ◽  
Johannes Heverhagen ◽  
...  

Abstract Objectives The purpose of this study was the assessment of volumetric CT perfusion (CTP) of the lower leg musculature in patients with symptomatic peripheral arterial disease (PAD) before and after interventional revascularisation. Methods Twenty-nine consecutive patients with symptomatic PAD of the lower extremities requiring interventional revascularisation were assessed prospectively. All patients underwent a CTP scan of the lower leg, and hemodynamic and angiographic assessment, before and after intervention. Ankle-brachial pressure index (ABI) was determined. CTP parameters were calculated with a perfusion software, acting on a no outflow assumption. A sequential two-compartment model was used. Differences in CTP parameters were assessed with non-parametric tests. Results The cohort consisted of 24 subjects with an occlusion, and five with a high-grade stenosis. The mean blood flow before/after (BFpre and BFpost, respectively) was 7.42 ± 2.66 and 10.95 ± 6.64 ml/100 ml*min−1. The mean blood volume before/after (BVpre and BVpost, respectively) was 0.71 ± 0.35 and 1.25 ± 1.07 ml/100 ml. BFpost and BVpost were significantly higher than BFpre and BVpre in the treated limb (p = 0.003 and 0.02, respectively), but not in the untreated limb (p = 0.641 and 0.719, respectively). Conclusions CTP seems feasible for assessing hemodynamic differences in calf muscles before and after revascularisation in patients with symptomatic PAD. We could show that CTP parameters BF and BV are significantly increased after revascularisation of the symptomatic limb. In the future, this quantitative method might serve as a non-invasive method for surveillance and therapy control of patients with peripheral arterial disease. Key Points • CTP imaging of the lower limb in patients with symptomatic PAD seems feasible for assessing hemodynamic differences before and after revascularisation in PAD patients. • This quantitative method might serve as a non-invasive method, for surveillance and therapy control of patients with PAD.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Manjot Kaur Grewal ◽  
Shruti Chandra ◽  
Alan Bird ◽  
Glen Jeffery ◽  
Sobha Sivaprasad

AbstractTo evaluate the effect of aging, intra- and intersession repeatability and regional scotopic sensitivities in healthy and age-related macular degeneration (AMD) eyes. Intra- and intersession agreement and effect of age was measured in healthy individuals. The mean sensitivity (MS) and pointwise retinal sensitivities (PWS) within the central 24° with 505 nm (cyan) and 625 nm (red) stimuli were evaluated in 50 individuals (11 healthy and 39 AMD eyes). The overall intra- and intersession had excellent reliability (intraclass correlation coefficient, ICC > 0.90) and tests were highly correlated (Spearman rs = 0.75–0.86). Eyes with subretinal drusenoid deposit (SDD) had reduced PWS centrally, particularly at inferior and nasal retinal locations compared with controls and intermediate AMD (iAMD) without SDD. There was no difference in MS or PWS at any retinal location between iAMD without SDD and healthy individuals nor between iAMD with SDD and non-foveal atrophic AMD groups. Eyes with SDD have reduced rod function compared to iAMD without SDD and healthy eyes, but similar to eyes with non-foveal atrophy. Our results highlight rod dysfunction is not directly correlated with drusen load and SDD location.


2019 ◽  
Vol 6 (2) ◽  
pp. 349 ◽  
Author(s):  
Rajendra Kumar ◽  
Nithin . ◽  
Sudha Rudrappa

Background: The aim of this study is to determine the success rate and safety of a non-invasive technique to obtain clean-catch midstream urine samples in newborns.Methods: Prospective bedside clinical study. After obtaining written informed consent,120 consecutive newborns admitted in NICU with no dehydration, poor feeding, need for immediate urine sample by invasive method  for whom urine collection was advised for various reasons who met the inclusion criteria were included in the study with consent being taken from the parents. After adequate milk intake supra pubic and lumbar para vertebral areas were stimulated in repeated cycles of 30 s until micturition began.Results: Success rate in obtaining a midstream urine sample within 5 min. The success rate was 90%. The mean time taken to collect urine was 64.24s, for males it was 62.55s and for females 65.93s.Conclusions: The technique has been demonstrated to be safe, quick and effective. The discomfort and time consumption usually associated with bag collection methods as well as invasive techniques can be avoided.


1990 ◽  
Vol 123 (6) ◽  
pp. 633-636 ◽  
Author(s):  
Leo Dunkel ◽  
Ilpo Huhtaniemi

Abstract. To investigate the role of gonadotropins in postnatal testicular activation, testosterone responsiveness to human chorionic gonadotropin was studied in 11 male infants (aged 5-180 days). The boys were given a single im injection of 5000 IU/1.7m2 hCG, and serum and salivary testosterone responses were then measured for 7 days. The results were compared with the serum testosterone responses of 8 older prepubertal boys (aged 1.7-10.4 years) studied with the same protocol. The mean (±sem) basal serum testosterone levels were 2.67±1.27 nmol/l in the infants and 0.09±0.02 nmol/l in the prepubertal boys (p<0.05). Both groups gave a significant response to hCG stimulation (p<0.001, ANOVA, one-way). The stimulated concentrations of serum testosterone were higher in the infants than in the prepubertal boys (p<0.001). The mean basal level of salivary testosterone was 30.5 ±7.0 and the mean maximal level was 97± 10.3 pmol/l in the infants (p<0.001). No age-related changes were observed in either basal or hCG-stimulated levels. In infants the mean (±sem) maximal hCG-stimulated increase was 25 ± 10-fold in serum and 8±4-fold in saliva (p=0.13). A clear stimulatory effect of hCG on testicular testosterone production was found, suggesting that the postnatal increase in serum testosterone concentration in male infants is gonadotropin-mediated. Salivary testosterone concentrations can be increased by hCG, indicating that measurements of salivary testosterone may provide an optional, non-invasive method for assessing gonadal function in children.


2002 ◽  
Vol 43 (5) ◽  
pp. 517-527 ◽  
Author(s):  
L. Olivecrona ◽  
J. Crafoord ◽  
H. Olivecrona ◽  
M. E. Noz ◽  
G. Q. Maguire ◽  
...  

Purpose: To develop a non-invasive method for detection of acetabular cup migration after total hip arthroplasty (THA) with a higher degree of accuracy than routine plain radiography. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients that had undergone THA. Using an in-house developed semiautomated program for volume merging, the pelves in the two examinations were fused and the acetabular cup was visually and numerically evaluated to test the method's accuracy in detecting migration. Results: In the visual evaluation of the best match a 1-mm translation of the cup was detectable. The numerical evaluation, comparing landmarks placed in the images of the acetabular cup and the head of the femur component in the two examinations, showed the mean difference in orientation of acetabular axes to be 2.5°, the mean distance between centre of cup face to be 2.5 mm and the mean distance between centre of the head of the prosthetic femoral component to be 1 mm. Conclusion: This method has a significantly higher accuracy than routine plain radiography in detecting acetabular cup migration and could be used in clinical practice. It gives both a visual and a numerical correlate to migration.


2020 ◽  
Vol 8 (B) ◽  
pp. 851-857
Author(s):  
Ivica Stojanoski ◽  
Toni Krstev ◽  
Lazar Iievski ◽  
Nerhim Tufekgioski ◽  
Sotir Stavridis

BACKGROUND: The extracorporeal shock wave lithotripsy (ESWL) is a non-invasive method in the treatment of urinary tract stones and its discovery has led to a complete change in the therapeutic strategy for urolithiasis. Due to the low morbidity and excellent fragmentation of the stones, ESWL has proven to be an effective and non-invasive method in the treatment of renal stones. AIM: The aim of this retrospective study is to evaluate the efficacy and safety of the ESWL as a monotherapy in the treatment of moderate size kidney stones with stone area (SA) of 100–300 mm². MATERIALS AND METHODS: We made a retrospective study of 98 patients with moderate size kidney stones with SA of 100–300 mm², divided into two subgroups, into a group with a SA of 100–200 mm² and with 200–300 mm², treated with ESWL in the period of November 2018–December 2019. The patients were treated with a third-generation electromagnetic lithotripter (Lithoskop®, Siemens Medical Systems, Erlangen, Germany), with a source of electromagnetic shocks (Pulso™) and dual ultrasonographic/fluoroscopic system for detection of the stones. The stone location, size, maximum energy used, localization technique, number of shock waves, sessions, re-treatment rate, and additional procedures were reviewed. All the patients before the intervention had a complete laboratory and radiological examinations. Postoperatively, patients were monitored on the 1st, 30th, and 90th post-operative days. RESULTS: Ninety-eight patients with solitary kidney stone with a SA of 100–300 mm² were treated with ESWL. The study included 58 men (59.18%) and 44 women (40.81%). The average length and width of the stone were 15.47 ± 2.68 mm and 12.99 ± 2.83 mm, respectively. The average surface area of the stones in our series was 203.78 ± 72.85 mm². The mean number of treatments for the entire series of patients was 1.82 ± 0.91. The mean number of shock waves for the total series of patients was 3899.11 ± 40. The mean energy used for the overall patient series was 110106.17 ± 21489.61 mJ. The total re-treatment rate was 47.95%. The entire rate of additional procedures was 19.38%. The overall success rate (SR) in our study was 77.55%. The efficiency quotient for the upper-middle and lower calyx was 55.57, 57.15, and 30.81, respectively. CONCLUSION: ESWL is a safe and effective method in the treatment of renal stones, and we recommend as the first method in the treatment of moderate size kidney stone with a surface area of 100–300 mm². The treatment of each patient should be individualized and take into account all favored and non-favored factors that influence the decision to choose extracorporeal lithotripsy as a method of treatment of medium-sized stones.


Author(s):  
Fariba Zarei ◽  
Mohammad Reza Sasani ◽  
Banafsheh Zeinali Rafsanjani ◽  
Mahdi Saeedi Moghadam

Introduction: Thyroid nodules are the most common findings among adults. Usually, Fine Needle Aspiration Biopsy (FNAB) can be used to distinguish the malignant and benign lesions. Application of a non-invasive method for determining the chance of malignancy in a nodule is desirable. Thyroid Imaging Reporting and Data System (TIRADS) was introduced to decrease the unnecessary FNABs and to optimize the management of these patients. The objective of this study was to assess the adherence of radiologist’s reports to TIRADS, after 10 years from the introduction of this system to radiologists in Fars Province. Methods: In this retrospective study, sonography report of the patients, who were referred to hospital for FNAB was assessed. If the patients did not have the previous sonography reports or the report was unreadable, they would be excluded from the study. Composition, echogenicity, shape, size, and margin were assessed and scored in this study. As the reports noted to each of the above-mentioned issues, score 1 was assigned to them. SPSS version 15 was used to analyze the data and calculated the standard deviation. Results: Sonography reports of 111 out of 250 patients was evaluated. The mean score of sonography reports from 5 was 2.63±0.86. The percentage of adherence of sonography reports to the expression of the first five categories was 52.61±17.25 %. Echogenic foci were also evaluated in the patients that it existed. The radiologists were reported them in almost 81% of cases. Conclusion: Overall adherence of sonographic report to TIRADS was 57.34%. The adherence can be definitely improved by training the radiologists.


2019 ◽  
Vol 3 (Supplement_1) ◽  
pp. S903-S903 ◽  
Author(s):  
Alice Kane ◽  
Michael B Schultz ◽  
Sarah Mitchell ◽  
Michael MacArthur ◽  
James Mitchell ◽  
...  

Abstract In mammals, the lack of accurate biomarkers for biological age is a current limitation to identifying novel aging interventions. Molecular biomarkers including DNA methylation hold promise but are invasive and currently expensive. The Frailty Index (FI) quantifies the accumulation of health-related deficits and is fast, cheap, and non-invasive. Studies have demonstrated that FI correlates with age and mortality risk in mice and humans. However, the FI has not been modelled to directly predict biological age or life expectancy. We tracked aging male C57BL/6 mice until their natural deaths, scoring them longitudinally with the FI. We find that FI score correlates with and is predictive of age and that some but not all parameters of the FI are individually well-correlated with age. To better predict chronological age, we performed an elastic net regression on the FI termed FRIGHT (Frailty Inferred Geriatric Health Timeline) Age. FRIGHT Age is a strong predictor of age (r2=0.73, median error=47.5 days), but is not superior to chronological age at predicting life expectancy. To better predict mortality, we built a random forest model termed the AFRAID (Analysis of Frailty and Death) score, which predicted survival at multiple ages (r2=0.375, median error = 46.4 days). The FRIGHT and AFRAID models were responsive to chronic treatment with enalapril (30mg/kg/day), an angiotensin converting enzyme inhibitor that extends healthspan, and methionine restriction, a dietary intervention that extends healthspan and lifespan. Our findings underscore the value of assessing non-invasive biomarkers for aging research and may help speed the identification of aging interventions.


2020 ◽  
pp. 1-10
Author(s):  
Jakub Novak ◽  
Andrew Busch ◽  
Pavel Kolar ◽  
Alena Kobesova

BACKGROUND: The abdominal muscles play an important respiratory and stabilization role, and in coordination with other muscles regulate intra-abdominal pressure (IAP) to stabilize the spine. OBJECTIVE: To examine a new, non-invasive method to measure activation of the abdominal wall and compare changes in muscle activation during respiration while breathing under a load, and during instructed breathing. METHODS: Thirty-five healthy individuals completed this observational crossover study. Two capacitive force sensors registered the abdominal wall force during resting breathing stereotype, instructed breathing stereotype and under a load. RESULTS: Mean abdominal wall force increased significantly on both sensors when holding the load compared to resting breathing (Upper Sensor: P< 0.0005, d=-0.46, Lower Sensor: P< 0.0005, d=-0.56). The pressure on both sensors also significantly increased during instructed breathing compared to resting breathing (US: P< 0.0005, d=-0.76, LS: P< 0.0005, d=-0.78). CONCLUSIONS: The use of capacitive force-sensors represent a new, non-invasive method to measure abdominal wall activity. Clinically, belts with capacitive force sensors can be used as a feedback tool to train abdominal wall activation.


2015 ◽  
Vol 75 (3) ◽  
Author(s):  
F. Salajka ◽  
V. Bartoš ◽  
J. Novosad ◽  
J. Št'ásek ◽  
J. Bis ◽  
...  

Background. Pulmonary hypertension (PH) in patients with advanced idiopathic pulmonary fibrosis (IPF) is a complication connected with unfavorable prognosis. Great efforts have been made in attempting to establish a reliable non-invasive method which would enable detection of this complication. In this context a formula using pulmonary function parameters was published with outstanding results. Methods. We tested the formula in 27 IPF patients who underwent a lung function examination, cardiac ultrasonography and catheterisation on the same day. Results. Pulmonary hypertension was detected by catheterisation in 17 patients (63%). In our group, contrary to the published data, the aforementioned formula was neither useful for detecting patients with a high probability of PH nor as a means of calculating the mean pulmonary artery pressure in individual patients (p=0.502 and p=0.833, respectively). Ultrasound examination reached borderline correlation with the values measured by catheterisation when we compare patients with relevant results (r=0.531, p=0.051). However, the examination gave no usable results in 13 patients (48%). Conclusion. Our data suggests that no reliable, noninvasive method is currently available for detecting and confirming PH in IPF patients. We did not confirm the usefulness of the published formula. Further carefully organised studies will be necessary to verify or refute it.


Sign in / Sign up

Export Citation Format

Share Document