scholarly journals Highway PC Bridge Inspection by 3.95 MeV X-Ray/Neutron Source

2021 ◽  
Author(s):  
Mitsuru Uesaka ◽  
Katsuhiro Dobashi ◽  
Yuki Mitsuya ◽  
Jian Yang ◽  
Joichi Kusano

We have developed portable 950 keV/3.95 MeV X-ray/neutron sources and applied them to inspection of PC concrete thicker than 200 mm within reasonable measuring time of seconds - minutes. T-girder-, Box- and slab- bridges are considered. Now we are to start X-ray transmission inspection for highway PC bridge (box) by using 3.95 MeV X-ray sources in Japan in 2020. By obtaining X-ray transmission images of no-grout-filling in PC sheath and thinning of PC wires, we plan to carry out numerical structural analysis to evaluate the degradation of strength. Finally, we are going to propose a technical guideline of nondestructive evaluation (NDE) of PC bridges by taking account of both X-ray inspection and structural analysis. Further, we are trying to detect rainwater detection in PC sheath, and asphalt and floor slab by the 3.95 MeV neutron source. This is expected to be an early degradation inspection. We have done preliminary experiments on X-ray transmission imaging of PC wires and on-grout-filling in the same height PCs in 450–750 mm thick concretes. Moreover, neutron back scattering detection of water in PC sheath is also explained.

Author(s):  
E. Loren Buhle ◽  
Pamela Rew ◽  
Ueli Aebi

While DNA-dependent RNA polymerase represents one of the key enzymes involved in transcription and ultimately in gene expression in procaryotic and eucaryotic cells, little progress has been made towards elucidation of its 3-D structure at the molecular level over the past few years. This is mainly because to date no 3-D crystals suitable for X-ray diffraction analysis have been obtained with this rather large (MW ~500 kd) multi-subunit (α2ββ'ζ). As an alternative, we have been trying to form ordered arrays of RNA polymerase from E. coli suitable for structural analysis in the electron microscope combined with image processing. Here we report about helical polymers induced from holoenzyme (α2ββ'ζ) at low ionic strength with 5-7 mM MnCl2 (see Fig. 1a). The presence of the ζ-subunit (MW 86 kd) is required to form these polymers, since the core enzyme (α2ββ') does fail to assemble into such structures under these conditions.


Author(s):  
K. A. Brookes ◽  
D. Finbow ◽  
Madeleine Samuel

Investigation of the particulate matter contained in the water sample, revealed the presence of a number of different types and certain of these were selected for analysis.An A.E.I. Corinth electron microscope was modified to accept a Kevex Si (Li) detector. To allow for existing instruments to be readily modified, this was kept to a minimum. An additional port is machined in the specimen region to accept the detector, with the liquid nitrogen cooling dewar conveniently housed in the left hand cupboard adjacent to the microscope column. Since background radiation leads to loss in the sensitivity of the instrument, great care has been taken to reduce this effect by screening and manufacturing components that are near the specimen from material of low atomic number. To change from normal transmission imaging to X-ray analysis, the special 4-position specimen rod is inserted through the normal specimen airlock.


Author(s):  
Steve Lindaas ◽  
Chris Jacobsen ◽  
Alex Kalinovsky ◽  
Malcolm Howells

Soft x-ray microscopy offers an approach to transmission imaging of wet, micron-thick biological objects at a resolution superior to that of optical microscopes and with less specimen preparation/manipulation than electron microscopes. Gabor holography has unique characteristics which make it particularly well suited for certain investigations: it requires no prefocussing, it is compatible with flash x-ray sources, and it is able to use the whole footprint of multimode sources. Our method serves to refine this technique in anticipation of the development of suitable flash sources (such as x-ray lasers) and to develop cryo capabilities with which to reduce specimen damage. Our primary emphasis has been on biological imaging so we use x-rays in the water window (between the Oxygen-K and Carbon-K absorption edges) with which we record holograms in vacuum or in air.The hologram is recorded on a high resolution recording medium; our work employs the photoresist poly(methylmethacrylate) (PMMA). Following resist “development” (solvent etching), a surface relief pattern is produced which an atomic force microscope is aptly suited to image.


1981 ◽  
Vol 46 (1) ◽  
pp. 6-19 ◽  
Author(s):  
Viktor Kettman ◽  
Ján Garaj ◽  
Jaroslav Majer

The crystal and molecular structure of [Cr(S2CN(CH2)5)3].2 CHCl3 was found by the X-ray structural analysis method. The value R 0.090 was found for 1 131 observed independent reflections. The substance crystallizes in a space group of symmetry P212121 with the following unit cell dimensions: a = 0.8675 (6), b = 1.815(2), c = 2.155(3) nm. The experimentally observed crustal density was 1.48 Mgm-3 and the value calculated for Z = 4 was 1.51 Mgm-3. The CrS6 coordination polyhedron has the shape of a trigonally distorted octahedron, where the D3 symmetry is a approximately retained. The degree of trigonal distortion expressed as the projection of the chelate S-Cr-S angle onto the plane perpendicular to the C3 pseudo axis is Φ = 41.7° (Φ = 60° for an octahedron). The skeleton of the structure formed by the complex molecules contains channels filled with chloroform molecules. The specific type of complex-chloroform interaction consists of the formation of hydrogen bonds of the chloroform protons with the fully occupied pπ-orbitals of the sulphur atoms in the coordination polyhedra. The low stability and crystal decomposition can be explained by loss of chloroform from the channels.


1999 ◽  
Vol 64 (6) ◽  
pp. 977-985 ◽  
Author(s):  
Bernd Wrackmeyer ◽  
Hans-Jörg Schanz ◽  
Wolfgang Milius ◽  
Catherine McCammon

Sodium hexaethyl-2,4-dicarba-nido-hexaborate(1-) (6), available from hexaethyl-2,4-dicarba- nido-hexaborane(8) (4) by deprotonation, reacts with deuterated methanol, CD3OD, to give back 4 without H/D exchange of the B-H-B hydrogen atom. The reaction of 6 with diethylboron chloride, Et2BCl, affords hexaethyl-2,4-dicarba-closo-hexaborane(6) (7), the first example of a peralkylated carborane of this type. In contrast, the reaction of 6 with boron tribromide, BBr3, leads mainly to 2,3,4,5,6,7-hexaethyl-2,4-dicarba-closo-heptaborane(7) (8), together with the corresponding 1-bromo derivative (9) and the closo-carborane 7 as side products. The reaction of two equivalents of 6 with FeCl2 gives the air-stable sandwich complex bis[hexaethyl-2,4-dicarba-nido-hexaborate(1-)]iron 10 which was characterised by X-ray structural analysis. All products were characterised by 1H, 11B and 13C NMR spectroscopy, and 57Fe Mössbauer spectroscopy was used to study 10.


1987 ◽  
Vol 1987-7 (1) ◽  
pp. 165-174
Author(s):  
Yoshihiro OKAMOTO
Keyword(s):  

1999 ◽  
Vol 23 (1) ◽  
pp. xiv-xiv
Author(s):  
Nader A. Al-Jalal ◽  
Robin G. Pritchard ◽  
Charles A. McAuliffe
Keyword(s):  

6-Methoxy-2-naphthonitrile undergoes photocycloaddition to 2-chloroacrylonitrile to give [2 + 2] cyclobutane adducts (1a and 1b), the structure of one of which (1a) has been unambiguously confirmed by an X-ray structural analysis.


2020 ◽  
Vol 35 (S1) ◽  
pp. S38-S42
Author(s):  
Soraia Rodrigues de Azeredo ◽  
Roberto Cesareo ◽  
Angel Guillermo Bustamante Dominguez ◽  
Ricardo Tadeu Lopes

Precious ornaments from the Museum Royal Tombs of Sipán were analyzed by X-ray computed microtomography (microCT). The ornaments analyzed were golden earrings produced by the Moche culture that flourished along the north coast of present-day Peru between approximately 100 and 600 AD. Sipán, also known as Huava Rajada, is a mochica archaeological complex in the north of Peru. In particular, the spectacular jewelry, mainly composed of gold, silver, and copper alloys, gilded copper, and tumbaga, from the Museum “Royal Tombs of Sipán,” in Lambayeque, north of Peru, are some of the most sophisticated metalworking ever produced of pre-Columbian America. A portable microCT system consisting of a high-resolution flat panel detector and a mini X-ray tube were used for the structural analysis of these ornaments. The microCT images show parts of the internal structure, highlighting the manufacturing technique and gold sheets joining techniques of the Moche artisans. Furthermore, the advantage of using the portable microCT system for nondestructive testing is clear when the sample cannot be taken to the laboratory.


Sign in / Sign up

Export Citation Format

Share Document