scholarly journals New Material for Si-Based Light Source Application for CMOS Technology

2019 ◽  
Author(s):  
Luong Thi Kim Phuong
Author(s):  
Michael T. Bucek ◽  
Howard J. Arnott

It is believed by the authors, with supporting experimental evidence, that as little as 0.5°, or less, knife clearance angle may be a critical factor in obtaining optimum quality ultrathin sections. The degree increments located on the knife holder provides the investigator with only a crude approximation of the angle at which the holder is set. With the increments displayed on the holder one cannot set the clearance angle precisely and reproducibly. The ability to routinely set this angle precisely and without difficulty would obviously be of great assistance to the operator. A device has been contrived to aid the investigator in precisely setting the clearance angle. This device is relatively simple and is easily constructed. It consists of a light source and an optically flat, front surfaced mirror with a minute black spot in the center. The mirror is affixed to the knife by placing it permanently on top of the knife holder.


Author(s):  
X. Lin ◽  
X. K. Wang ◽  
V. P. Dravid ◽  
J. B. Ketterson ◽  
R. P. H. Chang

For small curvatures of a graphitic sheet, carbon atoms can maintain their preferred sp2 bonding while allowing the sheet to have various three-dimensional geometries, which may have exotic structural and electronic properties. In addition the fivefold rings will lead to a positive Gaussian curvature in the hexagonal network, and the sevenfold rings cause a negative one. By combining these sevenfold and fivefold rings with sixfold rings, it is possible to construct complicated carbon sp2 networks. Because it is much easier to introduce pentagons and heptagons into the single-layer hexagonal network than into the multilayer network, the complicated morphologies would be more common in the single-layer graphite structures. In this contribution, we report the observation and characterization of a new material of monolayer graphitic structure by electron diffraction, HREM, EELS.The synthesis process used in this study is reported early. We utilized a composite anode of graphite and copper for arc evaporation in helium.


Author(s):  
F. Shaapur ◽  
M.J. Kim ◽  
Seh Kwang Lee ◽  
Soon Gwang Kim

TEM characterization and microanalysis of the recording media is crucial and complementary to new material system development as well as quality control applications. Due to the type of material generally used for supporting the medium, i.e., a polymer, conventional macro- and microthinning procedures for thin foil preparation are not applicable. Ultramicrotorny (UM) is a viable option and has been employed in previous similar studies. In this work UM has been used for preparation of XTEM samples from a magneto-optical (MO) recording medium in its original production format.The as-received material system consisted of a 4-layer, 2100 Å thick medium including a 300 Å TbFeCo layer enveloped by silicon nitride protective layers supported on a 1.2 mm thick × 135 mm (5.25 in.) diameter polycarbonate disk. Recording tracks had an approximate pitch of 1.6 μm separated by 800 Å deep peripheral grooves. Using a Buehler Isomet low-speed diamond saw, 1 mm wide and 20 mm long strips were cut out of the disk along the recording tracks.


Author(s):  
P.M. Houpt ◽  
A. Draaijer

In confocal microscopy, the object is scanned by the coinciding focal points (confocal) of a point light source and a point detector both focused on a certain plane in the object. Only light coming from the focal point is detected and, even more important, out-of-focus light is rejected.This makes it possible to slice up optically the ‘volume of interest’ in the object by moving it axially while scanning the focused point light source (X-Y) laterally. The successive confocal sections can be stored in a computer and used to reconstruct the object in a 3D image display.The instrument described is able to scan the object laterally with an Ar ion laser (488 nm) at video rates. The image of one confocal section of an object can be displayed within 40 milliseconds (1000 х 1000 pixels). The time to record the total information within the ‘volume of interest’ normally depends on the number of slices needed to cover it, but rarely exceeds a few seconds.


2018 ◽  
Vol 32 (4) ◽  
pp. 182-190 ◽  
Author(s):  
Kenta Matsumura ◽  
Koichi Shimizu ◽  
Peter Rolfe ◽  
Masanori Kakimoto ◽  
Takehiro Yamakoshi

Abstract. Pulse volume (PV) and its related measures, such as modified normalized pulse volume (mNPV), direct-current component (DC), and pulse rate (PR), derived from the finger-photoplethysmogram (FPPG), are useful psychophysiological measures. Although considerable uncertainties exist in finger-photoplethysmography, little is known about the extent of the adverse effects on the measures. In this study, we therefore examined the inter-method reliability of each index across sensor positions and light intensities, which are major disturbance factors of FPPG. From the tips of the index fingers of 12 participants in a resting state, three simultaneous FPPGs having overlapping optical paths were recorded, with their light intensity being changed in three steps. The analysis revealed that the minimum values of three coefficients of Cronbach’s α for ln PV, ln mNPV, ln DC, and PR across positions were .948, .850, .922, and 1.000, respectively, and that those across intensities were .774, .985, .485, and .998, respectively. These findings suggest that ln mNPV and PR can be used for psychophysiological studies irrespective of minor differences in sensor attachment positions and light source intensity, whereas and ln DC can also be used for such studies but under the condition of light intensity being fixed.


Author(s):  
Benoît Verdon

Since the 1950s, the growing interest of clinicians in using projective tests to study normal or pathological aging processes has led to the creation of several thematic tests for older adults. This development reflects their authors’ belief that the TAT is not suitable to the concerns and anxieties of elderly persons. The new material thus refers explicitly to situations related to age; it aims to enable older persons to express needs they cannot verbalize during consultations. The psychodynamic approach to thematic testing is based on the differentiation between the pictures’ manifest and latent content, eliciting responses linked to mental processes and issues the respondent is unaware of. The cards do not necessarily have to show aging characters to elicit identification: The situations shown in the pictures are linked to loss, rivalry, helplessness, and renunciation, all issues elderly respondents can identify with and that lead them to express their mental fragilities and resources. The article first explains the principles underlying four of these thematic tests, then develops several examples of stories told for card 3BM of the TAT, thus showing the effectiveness of this tool for the understanding and differentiation of loss-related issues facing older men and women.


2003 ◽  
Vol 104 ◽  
pp. 557-561 ◽  
Author(s):  
M. R. Howells ◽  
H. Chapman ◽  
S. Hau-Riege ◽  
H. He ◽  
S. Marchesini ◽  
...  

1988 ◽  
Vol 49 (C4) ◽  
pp. C4-41-C4-44
Author(s):  
G. J.T. DAVIDS ◽  
P. B. HARTOG ◽  
J. W. SLOTBOOM ◽  
G. STREUTKER ◽  
A. G. van der SIJDE ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document