scholarly journals Inspiration from Nature:Insights from Crustacean Chemical Sensors Can Lead to Successful Design of Artificial Chemical Sensors

10.5772/30722 ◽  
2012 ◽  
Author(s):  
Kristina S.
Author(s):  
Brian L. Rhoades

A gas reaction chamber has been designed and constructed for the JEM 7A transmission electron microscope which is based on a notably successful design by Hashimoto et. al. but which provides specimen tilting facilities of ± 15° aboutany axis in the plane of the specimen.It has been difficult to provide tilting facilities on environmental chambers for 100 kV microscopes owing to the fundamental lack of available space within the objective lens and the scope of structural investigations possible during dynamic experiments has been limited with previous specimen chambers not possessing this facility.A cross sectional diagram of the specimen chamber is shown in figure 1. The specimen is placed on a platinum ribbon which is mounted on a mica ring of the type shown in figure 2. The ribbon is heated by direct current, and a thermocouple junction spot welded to the section of the ribbon of reduced cross section enables temperature measurement at the point where localised heating occurs.


Author(s):  
Zhang zhaohua ◽  
Luo Dong ◽  
Guo Yisong

Since early 1970's the use of cold stage on SEM for observation of hydrated samples in their natural state has become more and more popular despite its high cost. Experiences gained from earlier experiments indicate that a successful design should incorporate thefollowing features:1. The specimen temperature should be below −135°C (the recrystallization point of water), lower the temperature, better the results.2. The frozen specimen, the cold block in the specimen preparation chamber, as well as the cold stage should be kept under vacuum at all times to keep them frost free.3. Different specimen preparation processes such as fracturing, coating and sublimation should be possible in one compact preparation chamber .


VASA ◽  
2015 ◽  
Vol 44 (5) ◽  
pp. 355-362 ◽  
Author(s):  
Marie Urban ◽  
Alban Fouasson-Chailloux ◽  
Isabelle Signolet ◽  
Christophe Colas Ribas ◽  
Mathieu Feuilloy ◽  
...  

Abstract. Summary: Background: We aimed at estimating the agreement between the Medicap® (photo-optical) and Radiometer® (electro-chemical) sensors during exercise transcutaneous oxygen pressure (tcpO2) tests. Our hypothesis was that although absolute starting values (tcpO2rest: mean over 2 minutes) might be different, tcpO2-changes over time and the minimal value of the decrease from rest of oxygen pressure (DROPmin) results at exercise shall be concordant between the two systems. Patients and methods: Forty seven patients with arterial claudication (65 + / - 7 years) performed a treadmill test with 5 probes each of the electro-chemical and photo-optical devices simultaneously, one of each system on the chest, on each buttock and on each calf. Results: Seventeen Medicap® probes disconnected during the tests. tcpO2rest and DROPmin values were higher with Medicap® than with Radiometer®, by 13.7 + / - 17.1 mm Hg and 3.4 + / - 11.7 mm Hg, respectively. Despite the differences in absolute starting values, changes over time were similar between the two systems. The concordance between the two systems was approximately 70 % for classification of test results from DROPmin. Conclusions: Photo-optical sensors are promising alternatives to electro-chemical sensors for exercise oximetry, provided that miniaturisation and weight reduction of the new sensors are possible.


2021 ◽  
Vol 11 (2) ◽  
pp. 699
Author(s):  
Worapol Tangsopa ◽  
Jatuporn Thongsri

At present, development of manufacturer’s ultrasonic cleaning tank (UCT) to match the requirements from consumers usually relies on computer simulation based on harmonic response analysis (HRA). However, this technique can only be used with single-frequency UCT. For dual frequency, the manufacturer used information from empirical experiment alongside trial-and-error methods to develop prototypes, resulting in the UCT that may not be fully efficient. Thus, lack of such a proper calculational method to develop the dual frequency UCT was a problem that greatly impacted the manufacturers and consumers. To resolve this problem, we proposed a new model of simulation using transient dynamics analysis (TDA) which was successfully applied to develop the prototype of dual frequency UCT, 400 W, 18 L in capacity, eight horn transducers, 28 and 40 kHz frequencies for manufacturing. The TDA can indicate the acoustic pressure at all positions inside the UCT in transient states from the start to the states ready for proper cleaning. The calculation also reveals the correlation between the positions of acoustic pressure and the placement positions of transducers and frequencies. In comparison with the HRA at 28 kHz UCT, this TDA yielded the results more accurately than the HRA simulation, comparing to the experiments. Furthermore, the TDA can also be applied to the multifrequency UCTs as well. In this article, the step-by-step development of methodology was reported. Finally, this simulation can lead to the successful design of the high-performance dual frequencies UCT for the manufacturers.


Agriculture ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 658
Author(s):  
Subin Mattara Chalill ◽  
Snehaunshu Chowdhury ◽  
Ramanujam Karthikeyan

Controlled crop growth parameters, such as average air velocity, air temperature, and relative humidity (RH), inside the greenhouse are necessary prerequisites for commercial greenhouse operation. Frequent overshoots of such parameters are noticed in the Middle East. Traditional heating ventilation and air-conditioning (HVAC) systems in such greenhouses use axial fans and evaporative cooling pads to control the temperature. Such systems fail to respond to the extreme heat load variations during the day. In this study, we present the design and implementation of a single span, commercial greenhouse using box type evaporative coolers (BTEC) as the backbone of the HVAC system. The HVAC system is run by a fully-automated real time feedback-based climate management system (CMS). A full-scale, steady state computational fluid dynamics (CFD) simulation of the greenhouse is carried out assuming peak summer outdoor conditions. A pilot study is conducted to experimentally monitor the environmental parameters in the greenhouse over a 20-h period. The recorded data confirm that the crop growth parameters lie within their required ranges, indicating a successful design and implementation phase of the commercial greenhouse on a pilot scale.


Sign in / Sign up

Export Citation Format

Share Document