scholarly journals Evolution of Biochemical Diagnosis of Acute Coronary Syndrome – Impact Factor of High Sensitivity Cardiac Troponin Assays

10.5772/28634 ◽  
2012 ◽  
Author(s):  
Amparo Galán ◽  
Josep Lupón ◽  
Antoni Bayés-Genis
Author(s):  
Paul Simpson ◽  
Rosy Tirimacco ◽  
Penelope Cowley ◽  
May Siew ◽  
Narelle Berry ◽  
...  

Background The management of patients presenting with symptoms suggestive of acute coronary syndrome is a significant challenge for clinicians. Guidelines for the diagnosis of acute myocardial infarction require a rise and/or fall of cardiac troponin, along with other criteria. Knowing what constitutes a significant delta change from baseline is still unclear and the literature is varied. Methods We compared three methods for determining cardiac troponin delta changes (relative, absolute and z-scores) for detecting acute myocardial infarction in 806 patients presenting to an emergency department with symptoms suggestive of acute coronary syndrome. Blood specimens were collected at admission and 2, 3, 4 and 6 h postadmission and tested on the Roche Elecsys high-sensitivity troponin T assay. Results A positive diagnosis for acute myocardial infarction was found in 39 (4.8%) patients. ROC AUC showed better performance for the absolute and z-score delta change (0.959–0.988 and 0.956–0.988, respectively) compared with relative delta change (0.921–0.960) at all time points in the diagnosis of acute myocardial infarction. Optimal timing for the second sample was at 4–6 h postadmission. Conclusions Although not statistically significant, the results show a trend of absolute and z-score delta change performing better than relative delta change for the diagnosis of acute myocardial infarction. The z-score approach allows for a single cut-off value across multiple high-sensitivity assays which could be useful in the clinical setting. Our study also highlighted the importance of interpreting cardiac troponin changes in the clinical context with a combination of the patient’s clinical history and electrocardiogram.


2019 ◽  
Vol 20 (8) ◽  
pp. 504-509 ◽  
Author(s):  
Erica Rocco ◽  
Giulio La Rosa ◽  
Giovanna Liuzzo ◽  
Luigi M. Biasucci

2017 ◽  
Vol 38 (suppl_1) ◽  
Author(s):  
V.J. Van Den Berg ◽  
V.A.W.M. Umans ◽  
K.M. Akkerhuis ◽  
R.M. Oemrawsingh ◽  
F.W. Asselbergs ◽  
...  

2012 ◽  
Vol 58 (8) ◽  
pp. 1208-1214 ◽  
Author(s):  
Volkher Scharnhorst ◽  
Krisztina Krasznai ◽  
Marcel van 't Veer ◽  
Rolf H Michels

Abstract BACKGROUND New-generation high-sensitivity assays for cardiac troponin have lower detection limits and less imprecision than earlier assays. Reference 99th-percentile cutoff values for these new assays are also lower, leading to higher frequencies of positive test results. When cardiac troponin concentrations are minimally increased, serial testing allows discrimination of myocardial infarction from other causes of increased cardiac troponin. We assessed various measures of short-term variation, including absolute concentration changes, reference change values (RCVs), and indices of individuality (II) for 2 cardiac troponin assays in emergency department (ED) patients. METHODS We collected blood from patients presenting with cardiac chest pain upon arrival in the ED and 2, 6, and 12 h later. Cardiac troponin was measured with the high-sensitivity cardiac troponin T (hs-cTnT) assay (Roche Diagnostics) and a sensitive cTnI assay (Siemens Diagnostics). Cardiac troponin results from 67 patients without acute coronary syndrome or stable angina were used in calculating absolute changes in cardiac troponin, RCVs, and II. RESULTS The 95th percentiles for absolute change in cardiac troponin were 8.3 ng/L for hs-cTnT and 28 ng/L for cTnI. Within-individual and total CVs were 11% and 14% for hs-cTnT and 18% and 21% for cTnI, respectively. RCVs were 38% (hs-cTnT) and 57% (cTnI). The corresponding log-normal RCVs were +46%/−32% for hs-cTnT and +76%/−43% for cTnI. II values were 0.31 (cTnI) and 0.12 (hs-cTnT). CONCLUSIONS The short-term variations and IIs of cardiac troponin were low in ED patients free of ischemic myocardial necrosis. The detection of cardiac troponin variation exceeding reference thresholds can help to identify ED patients with acute myocardial necrosis whereas variation within these limits renders acute coronary syndrome unlikely.


Sign in / Sign up

Export Citation Format

Share Document