scholarly journals Prediction based on the Kennedy-O’Hagan calibration model: asymptotic consistency and other properties

Author(s):  
Rui Tuo ◽  
Jeff Wu
1997 ◽  
Vol 78 (02) ◽  
pp. 855-858 ◽  
Author(s):  
Armando Tripodi ◽  
Veena Chantarangkul ◽  
Marigrazia Clerici ◽  
Barbara Negri ◽  
Pier Mannuccio Mannucci

SummaryA key issue for the reliable use of new devices for the laboratory control of oral anticoagulant therapy with the INR is their conformity to the calibration model. In the past, their adequacy has mostly been assessed empirically without reference to the calibration model and the use of International Reference Preparations (IRP) for thromboplastin. In this study we reviewed the requirements to be fulfilled and applied them to the calibration of a new near-patient testing device (TAS, Cardiovascular Diagnostics) which uses thromboplastin-containing test cards for determination of the INR. On each of 10 working days citrat- ed whole blood and plasma samples were obtained from 2 healthy subjects and 6 patients on oral anticoagulants. PT testing on whole blood and plasma was done with the TAS and parallel testing for plasma by the manual technique with the IRP CRM 149S. Conformity to the calibration model was judged satisfactory if the following requirements were met: (i) there was a linear relationship between paired log-PTs (TAS vs CRM 149S); (ii) the regression line drawn through patients data points, passed through those of normals; (iii) the precision of the calibration expressed as the CV of the slope was <3%. A good linear relationship was observed for calibration plots for plasma and whole blood (r = 0.98). Regression lines drawn through patients data points, passed through those of normals. The CVs of the slope were in both cases 2.2% and the ISIs were 0.965 and 1.000 for whole blood and plasma. In conclusion, our study shows that near-patient testing devices can be considered reliable tools to measure INR in patients on oral anticoagulants and provides guidelines for their evaluation.


Author(s):  
Klimenko Lina Yu ◽  
Shkarlat Galyna L ◽  
Shovkova Zoia V ◽  
Yaremenko Vitaliy D ◽  
Shpychak Oleg S

Metronidazole is the most popular representative of antiprotozoal medicines from the group of 5-nitroimidazoles. Metronidazole blocks the enzymes of alcohol dehydrogenase and acetaldehyde dehydrogenase, therefore when its joint taking with alcohol it is observed the strong intoxication syndrome and fatal poisonings too. Therefore metronidazole can be a potential object of chemical toxicological investigations. The purpose of our paper is to develop HPLC/UV-procedure of metronidazole quantification with application of the system of HPLC-analyzer MiLiChrome® A-0230 implemented in practice of forensic medical laboratories in Russia and Ukraine and carry out step-by-step validation of the developed procedure. Chromatographic conditions: Eluent A (0.2 M LiClO4 – 0.005 M HClO4) and Eluent B (acetonitrile) wereused as the mobile phase components; HPLC microcolumn Ø2×75 mm and ProntoSIL 120-5-C18 AQ, 5 μm were used as an analytical column; temperature was 40°С; flow rate was 100 μl/min; gradient elution mode was from 5% to 100% Eluent B for 40 min, then 100% Eluent B for 3 min; detection was performed at 277 nm. Retention time for metronidazole is 5.95 min. Since metronidazole is easy soluble and stable enough in the solutions of diluted alkalis 0.001 M sodium hydroxide solution has been proposed for preparation of the solutions in developing HPLC/UV-procedure of metronidazole quantification. Validation of the procedure has been carried out in the variants of the method of calibration curve and method of standard by such parameters as in process stability, linearity/calibration model, accuracy and precision within 3 different analytical runs using different batches of reagents and different glassware; experiments have been performed by three different analysts. New procedure of metronidazole quantitative determination by the method of HPLC/UV has been developed. Its validation has been carried out and acceptability for application has been shown.


2021 ◽  
pp. 000370282110123
Author(s):  
Hemalaxmi Rajavelu ◽  
Nilesh J Vasa ◽  
Satyanarayanan Seshadri

A benchtop Laser-Induced Breakdown Spectroscopy (LIBS) is demonstrated to determine the elemental carbon content present in raw coal used for combustion in power plants. The spectral intensities of molecular CN and C2 emission are measured together with the atomic carbon (C) and other inorganic elements (Si, Fe, Mg, Al, Ca, Na, and K) in the LIBS spectrum of coal. The emission persistence time of C2 molecule emission is measured from the coal plasma generated by a nanosecond laser ablation with a wavelength of 266 nm in the Ar atmosphere. The emission persistence time of molecular C2 emission along with the spectral intensities of major ash elements (Fe, Si, Al, and Ca) and carbon emissions (atomic C, molecular CN, and C2) shows a better relationship with the carbon wt% of different coal samples. The calibration model to measure elemental carbon (wt%) is developed by combining the spectral characteristics (Spectral intensity) and the temporal characteristics (Emission persistence time of C2 molecule emission). The temporal characteristic studies combined with the spectroscopic data in the PLSR (Partial Least Square Regression) model has resulted in an improvement in the root mean square error of validation (RMSEV), and the relative standard deviation (RSD) is reduced from 10.86% to 4.12% and from 11.32% to 6.04%, respectively.


Author(s):  
Chen Chen ◽  
Guangming Xiong ◽  
Zhehua Zhang ◽  
Jianwei Gong ◽  
Jianyong Qi ◽  
...  

2021 ◽  
pp. 338890
Author(s):  
Mark Schoot ◽  
Christiaan Kapper ◽  
Gijs van Kessel ◽  
Geert Postma ◽  
Lutgarde MC. Buydens ◽  
...  

Atmosphere ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 645
Author(s):  
Kristen Okorn ◽  
Michael Hannigan

As low-cost sensors have become ubiquitous in air quality measurements, there is a need for more efficient calibration and quantification practices. Here, we deploy stationary low-cost monitors in Colorado and Southern California near oil and gas facilities, focusing our analysis on methane and ozone concentration measurement using metal oxide sensors. In comparing different sensor signal normalization techniques, we propose a z-scoring standardization approach to normalize all sensor signals, making our calibration results more easily transferable among sensor packages. We also attempt several different physical co-location schemes, and explore several calibration models in which only one sensor system needs to be co-located with a reference instrument, and can be used to calibrate the rest of the fleet of sensor systems. This approach greatly reduces the time and effort involved in field normalization without compromising goodness of fit of the calibration model to a significant extent. We also explore other factors affecting the performance of the sensor system quantification method, including the use of different reference instruments, duration of co-location, time averaging, transferability between different physical environments, and the age of metal oxide sensors. Our focus on methane and stationary monitors, in addition to the z-scoring standardization approach, has broad applications in low-cost sensor calibration and utility.


2020 ◽  
pp. emermed-2018-208309
Author(s):  
Hanna Vihonen ◽  
Mitja Lääperi ◽  
Markku Kuisma ◽  
Jussi Pirneskoski ◽  
Jouni Nurmi

BackgroundTo determine if prehospital blood glucose could be added to National Early Warning Score (NEWS) for improved identification of risk of short-term mortality.MethodsRetrospective observational study (2008–2015) of adult patients seen by emergency medical services in Helsinki metropolitan area for whom all variables for calculation of NEWS and a blood glucose value were available. Survival of 24 hours and 30 days were determined. The NEWS parameters and glucose were tested by multivariate logistic regression model. Based on ORs we formed NEWSgluc model with hypoglycaemia (≤3.0 mmol/L) 3, normoglycaemia 0 and hyperglycaemia (≥11.1 mmol/L) 1 points. The scores from NEWS and NEWSgluc were compared using discrimination (area under the curve), calibration (Hosmer-Lemeshow test), likelihood ratio tests and reclassification (continuous net reclassification index (cNRI)).ResultsData of 27 141 patients were included in the study. Multivariable regression model for NEWSgluc parameters revealed a strong association with glucose disturbances and 24-hour and 30-day mortality. Likelihood ratios (LRs) for mortality at 24 hours using a cut-off point of 15 were for NEWSgluc: LR+ 17.78 and LR− 0.96 and for NEWS: LR+ 13.50 and LR− 0.92. Results were similar at 30 days. Risks per score point estimation and calibration model showed glucose added benefit to NEWS at 24 hours and at 30 days. Although areas under the curve were similar, reclassification test (cNRI) showed overall improvement of classification of survivors and non-survivors at 24 days and 30 days with NEWSgluc.ConclusionsIncluding glucose in NEWS in the prehospital setting seems to improve identification of patients at risk of death.


1998 ◽  
Vol 52 (5) ◽  
pp. 717-724 ◽  
Author(s):  
Charity Coffey ◽  
Alex Predoehl ◽  
Dwight S. Walker

The monitoring of the effluent of a rotary dryer has been developed and implemented. The vapor stream between the dryer and the vacuum is monitored in real time by a process fiber-optic coupled near-infrared (NIR) spectrometer. A partial least-squares (PLS) calibration model was developed on the basis of solvents typically used in a chemical pilot plant and uploaded to an acousto-optic tunable filter NIR (AOTF-NIR). The AOTF-NIR is well suited to process monitoring as it electrically scans a crystal and hence has no moving parts. The AOTF-NIR continuously fits the PLS model to the currently collected spectrum. The returned values can be used to follow the drying process and determine when the material can be unloaded from the dryer. The effluent stream was monitored by placing a gas cell in-line with the vapor stream. The gas cell is fiber-optic coupled to a NIR instrument located 20 m away. The results indicate that the percent vapor in the effluent stream can be monitored in real time and thus be used to determine when the product is free of solvent.


Sign in / Sign up

Export Citation Format

Share Document