scholarly journals Fibula Osteocutaneous Flap for Mandible Reconstruction after Ameloblastoma Resection: Amending Technique to Reduce Ischaemic Time

2007 ◽  
Vol 1 (1) ◽  
pp. 39-41
Author(s):  
EK Chee ◽  
T Sara Ahmad ◽  
ES Ng
1995 ◽  
Vol 11 (03) ◽  
pp. 215-219 ◽  
Author(s):  
Achilleas Thoma ◽  
Murray Allen ◽  
Beth Tadeson ◽  
Stuart Archibald ◽  
Stanley Jackson ◽  
...  

Microsurgery ◽  
2021 ◽  
Vol 41 (3) ◽  
pp. 223-232
Author(s):  
Dicle Aksoyler ◽  
Luigi Losco ◽  
Alberto Bolletta ◽  
Alp Ercan ◽  
Shih‐Heng Chen ◽  
...  

2020 ◽  
Vol 13 (12) ◽  
pp. e239286
Author(s):  
Kumar Nilesh ◽  
Prashant Punde ◽  
Nitin Shivajirao Patil ◽  
Amol Gautam

Ossifying fibroma (OF) is a rare, benign, fibro-osseous lesion of the jawbone characterised by replacement of the normal bone with fibrous tissue. The fibrous tissue shows varying amount of calcified structures resembling bone and/or cementum. The central variant of OF is rare, and shows predilection for mandible among the jawbone. Although it is classified as fibro-osseous lesion, it clinically behaves as a benign tumour and can grow to large size, causing bony swelling and facial asymmetry. This paper reports a case of large central OF of mandible in a 40-year-old male patient. The lesion was treated by segmental resection of mandible. Reconstruction of the surgical defect was done using avascular fibula bone graft. Role of three-dimensional printing of jaw and its benefits in surgical planning and reconstruction are also highlighted.


Head & Neck ◽  
2015 ◽  
Vol 38 (3) ◽  
pp. 434-438 ◽  
Author(s):  
Dustin A. Silverman ◽  
Wojciech H. Przylecki ◽  
Jill M. Arganbright ◽  
Yelizaveta Shnayder ◽  
Kiran Kakarala ◽  
...  

2014 ◽  
Vol 654 ◽  
pp. 187-190 ◽  
Author(s):  
Hong Hua Zhao ◽  
Jian Ying Tian ◽  
Dong Song Li ◽  
Chang Sheng Ai

Clinical treatment for mandible defects is Mandible Reconstruction Surgery (MRS) including bone grafts, distraction osteogenesis and bone tissue engineering, however, MRS is operated by doctors without 3D navigation at present which leads to lots of disadvantages such as bad operational control, low positioning accuracy and poor stability. Therefore, a robotic surgical system was designed to assist surgeons on manipulating. For this study, the robot system was given in brief, then mechanical design and control system of the novel three-arm robot.And experiment results in this study show that the robot works stably and accurately. The development of this medical robot system contributes to the promotion and popularization of the MRS in clinics.


Sign in / Sign up

Export Citation Format

Share Document