scholarly journals Decorative values of selected cultivars of climbing roses (Rosa L.) with regard to thermal conditions

2012 ◽  
Vol 60 (1) ◽  
pp. 135-142
Author(s):  
Zofia Włodarczyk ◽  
Agnieszka Perzanowska

In the years 2004-2006 in Kraków, phenological observations of climbing roses were conducted in order to determine the length and dates of their flowering period. The diameters of their flowers were also compared. Eight flowering repeating cultivars were selected for the experiment: 'Climbing Souvenir de la Malmaison', 'Dortmund', 'Golden Showers', 'Goldstern', 'New Dawn', 'Parade', 'Sympathie' and 'White New Dawn'. During the studies, the shrub roses were not artificially watered in order to create conditions similar to those prevailing in public green areas. It was observed that irrespective of the air temperature pattern in a given year, the studied cultivars did not bloom before 15 June. In 2006 high temperatures (above 20<sup>o</sup>C), which continued throughout the whole flowering period, caused its shortening, and the interval between the first and the next flowering in the season lasted longer than in the previous years. In the years 2004-2006, the cultivar 'New Dawn' bloomed the longest. In 2005 the studied cultivars produced larger flowers than the next year. The cultivars 'Dortmund' and 'White New Dawn' were characterised by the smallest diameter of flowers, whereas 'Climbing Souvenir de la Malmaison', 'Golden Showers' and 'Parade' were marked by the largest diameter.

2021 ◽  
Vol 13 (4) ◽  
pp. 640
Author(s):  
Sadroddin Alavipanah ◽  
Dagmar Haase ◽  
Mohsen Makki ◽  
Mir Muhammad Nizamani ◽  
Salman Qureshi

The changing climate has introduced new and unique challenges and threats to humans and their environment. Urban dwellers in particular have suffered from increased levels of heat stress, and the situation is predicted to continue to worsen in the future. Attention toward urban climate change adaptation has increased more than ever before, but previous studies have focused on indoor and outdoor temperature patterns separately. The objective of this research is to assess the indoor and outdoor temperature patterns of different urban settlements. Remote sensing data, together with air temperature data collected with temperature data loggers, were used to analyze land surface temperature (outdoor temperature) and air temperature (indoor temperature). A hot and cold spot analysis was performed to identify the statistically significant clusters of high and low temperature data. The results showed a distinct temperature pattern across different residential units. Districts with dense urban settlements show a warmer outdoor temperature than do more sparsely developed districts. Dense urban settlements show cooler indoor temperatures during the day and night, while newly built districts show cooler outdoor temperatures during the warm season. Understanding indoor and outdoor temperature patterns simultaneously could help to better identify districts that are vulnerable to heat stress in each city. Recognizing vulnerable districts could minimize the impact of heat stress on inhabitants.


Energies ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 860
Author(s):  
Piotr Michalak

Modern buildings with new heating, ventilation and air conditioning (HVAC) systems offer possibility to fit parameters of the indoor environment to the occupants’ requirements. The present paper describes the results of measurements performed in an office room in the first Polish passive commercial office building during four months of normal operation. They were used to calculate parameters describing thermal comfort: vertical air temperature profile, floor surface temperature, predicted mean vote (PMV) and predicted percent of dissatisfied (PPD). Obtained results confirmed good thermal conditions in the analysed room. The average temperature of the floor’s surface varied from 20.6 °C to 26.2 °C. The average vertical air temperature, calculated for working days, was from 22.5 °C to 23.1 °C. The temperature difference between the floor and 5 cm below the ceiling was from −0.9 °C to 6.3 °C. The PMV index varied from 0.52 to 1.50 indicating ‘slightly warm’ sensation, in spite of ‘neutral’ reported by employees. Also measured cooling and heating energy consumption was presented. The performed measurements confirmed the ability of thermally activated building system (TABS) to keep good thermal conditions.


Author(s):  
MARGARYAN V.G. ◽  

The features of the thermal regime of the surface air layer in the Debed river basin are considered. A statistical analysis of the average annual and average seasonal values of air temperature from 1964 to 2018 was carried out, two periods were identified, their time course was shown. The analysis was carried out using data from six meteorological stations representing the lowland, mountain and high-mountain climatic zones of the Debed river basin. A correlation was obtained between the absolute altitude and the monthly average values of air temperature for January and July, which can be used to assess the thermal conditions of unexplored or poorly studied territories and for cartography. The time course of average values of air temperatures for the seasonal period has been studied. Analysis of trend lines of temporal changes in air temperatures shows that in all situations on the territory of the basin as a whole, there is a tendency of temperature growth. Moreover, with a range of interannual fluctuations, a break in the course of temperatures in the early to mid 1990 is clearly visible, after which their significant increase began. It turned out that a significant increase in seasonal temperatures is observed especially over the period 1993-2018, which means that the annual warming after the mid 1990 occurred primarily due to summer and spring seasons. The regular dynamics indicates that in the studied area in terms of temperatures, a tendency of softening winters, a decrease in the water content of rivers, aridization of the climate. The results obtained can be used to assess the regularities of the spatial-temporal distribution of the temperature of the study area, to clarify the thermal balance, for the rational use of heat resources, as well as in the development of strategic programs for longterm analysis.


2018 ◽  
Vol 13 (3) ◽  
pp. 292-298
Author(s):  
ATHANASIOS KAMOUTSIS ◽  
KOSTAS CHRONOPOULOS ◽  
ARISTIDIS MATSOUKIS

Topography and canopy play a decisive role on air temperature (T) conditions in forested areas. Air temperature is a crucial factor in decision making process for the development of these areas. To our knowledge, there is no information regarding the effect of topography along with canopy cover (Pc) on thermal conditions of a vulnerable mountainous forested region of Greece, Mount (Mt) Aenos in the island of Cephalonia, Ionian Islands, Greece. Therefore, the purpose of our work is the investigation of the aforementioned parameters, especially the effect of altitude (alt) and Pc on T of Mt Aenos. Mean values for maximum air temperature (Tx) and Pc were estimated for twelve sites at various alts in Mt Aenos during the period May-October of three consecutive years (2011-2013). The analysis of the results showed that Tx was related to alt and Pc. Altitude has a greater effect on T in relation to Pc. When examining same or similar alts, an increase of Pc up to 51% resulted in a significant decrease of Tx (p<0.05) up to 3.6 °C. Our findings could be taken into account in planning the construction of hiking trails for recreational activities in Mt Aenos, and, in general, in mountainous forest areas of special importance.


2015 ◽  
Vol 2 (3) ◽  
pp. 803-826 ◽  
Author(s):  
Alejandra S. Coronel ◽  
◽  
Susana R. Feldman ◽  
Emliano Jozami ◽  
Kehoe Facundo ◽  
...  

Buildings ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 124 ◽  
Author(s):  
Claire Tam ◽  
Yuqing Zhao ◽  
Zaiyi Liao ◽  
Lian Zhao

Indoor air quality and thermal conditions are important considerations when designing indoor spaces to ensure occupant health, satisfaction, and productivity. Carbon dioxide (CO2) concentration and indoor air temperature are two measurable parameters to assess air quality and thermal conditions within a space. Occupants are progressively affected by the indoor environment as the time spent indoors prolongs. Specifically, there is an interest in carrying out investigations on the indoor environment through surveying existing Heating, Ventilation, Air Conditioning (HVAC) system operations in classrooms. Indoor air temperature and CO2 concentration in multiple lecture halls in Toronto, Canada were monitored; observations consistently show high indoor air temperature (overheating) and high CO2 concentration. One classroom is chosen as a representative case study for this paper. The results verify a strong correlation between the number of occupants and the increase in air temperature and CO2 concentration. Building Energy Simulation (BES) is used to investigate the causes of discomfort in the classroom, and to identify methods for regulating the temperature and CO2 concentration. This paper proposes retro-commissioning strategies that could be implemented in institutional buildings; specifically, the increase of outdoor airflow rate and the addition of occupancy-based pre-active HVAC system control. The proposed retrofit cases reduce the measured overheating in the classrooms by 2-3 °C (indoor temperature should be below 23 °C) and maintain CO2 concentration under 900 ppm (the CO2 threshold is 1000 ppm), showing promising improvements to a classroom’s thermal condition and indoor air quality.


2019 ◽  
Vol 887 ◽  
pp. 467-474
Author(s):  
Radoslav Ponechal ◽  
Renáta Korenková ◽  
Daniela Štaffenová

This study solves a problem of the dynamic thermal performance of the residential attic space in moderate climatic zone. Heat loss into the attic space is difficult to be accurately determined by the quasi-stationary method. It depends on the thermal resistance of the ceiling, thermal resistance of the roof, ventilation characteristics and other details, such as the solar absorption of the roofing material or roof orientation. The paper presents results of some parametric simulative calculations, which were calibrated with measurements of air temperature in the attic space during the summer, winter and transitional season. It compares the mean air temperature in the ventilated and non-ventilated attics. The difference between the use of bright and dark color of the roof cover is also compared. An alternative with half thickness of thermal insulation was also simulated. Based on measurements and then the simulation the adjustment factor adjustment factor for heat transfer coefficient was quantified..


2019 ◽  
Vol 116 ◽  
pp. 00085
Author(s):  
Sylwia Szczęśniak ◽  
Juliusz Walaszczyk

The knowledge about dynamic changing heating and cooling load in existing building is essential for proper energy management. Whenever existing building is analyzed or ventilation system is going optimized, it’s essential to estimate temporary sensible and latent heat based on historical data. The basic conditions for heat calculations are quasi-stable thermal conditions. If supply air temperature significantly varies in short time, what happens very often, the calculations can give untrue results. The procedure described in this article improves usability of measured data affected by rapid supply air temperature changing. Therefore real sensible and latent heat can be calculated, what it is important for future optimization process. Specified, on the basis of varying supply and exhaust air temperatures, thermal loads range from -55.8 kW to 40.7 kW was substitute to more authentic range from -14.1 kW to 51.2 kW received from the conducted simulations. In addition, the data obtained from the simulation showed that latent heat gains were associated with the air temperature in the room, and not with the operation mode of the ventilation unit (day/night) as observed on the basis of historical data.


2018 ◽  
Vol 9 (1) ◽  
pp. 75
Author(s):  
Vadim R. ALABYEV ◽  
Marina N. KRUK ◽  
Mariia A. KOROBITCYNA ◽  
Igor S. STEPANOV

Thermal conditions in petroleum tanks are important for maintaining optimal sanitary and hygienic standards, which contribute to increasing the working capacity of people. Therefore, the set problems are of great importance for research. The main goal of the work is to study the influence of environmental technologies on the economic component. To achieve this goal, the authors substantiated design solutions for the use of refrigeration equipment to improve and normalize thermal conditions in drilling galleries in the extraction of oil by underground. It is established that the main increase in air temperature is observed in the drilling gallery and on the outgoing air jet in the slope. According to the results of thermal surveys, it is determined that the cooling demand of the drilling gallery, provided that the air temperature at the end of the slope does not exceed 35.0°C, is about 1000 kW. It is established that the use of environmental technologies contributes to the improvement of working conditions. And also has a high level of profitability and payback.


Sign in / Sign up

Export Citation Format

Share Document