scholarly journals An Experimental Investigation of Heat Transfer Coefficients for Spiral Plate Heat Exchanger

2008 ◽  
Vol 2 (5) ◽  
Author(s):  
Kaliannan Saravanan ◽  
Rangasamy Rajavel
Author(s):  
Louis C. Burmeister

A formula is derived for the dependence of heat exchanger effectiveness on the number of transfer units for a spiral-plate heat exchanger with equal capacitance rates. The difference-differential equations that describe the temperature distributions of the two counter-flowing fluids, neglecting thermal radiation, are solved symbolically to close approximation. Provision is made for offset inlet and exit of the hot and cold fluids at the outer periphery and for large heat transfer coefficients in entrance regions. The peak effectiveness and the number of transfer units at which it occurs are predicted.


2016 ◽  
Vol 37 (3) ◽  
pp. 19-29 ◽  
Author(s):  
Janusz T. Cieśliński ◽  
Artur Fiuk ◽  
Krzysztof Typiński ◽  
Bartłomiej Siemieńczuk

Abstract This study is focused on experimental investigation of selected type of brazed plate heat exchanger (PHEx). The Wilson plot approach was applied in order to estimate heat transfer coefficients for the PHEx passages. The main aim of the paper was to experimentally check ability of several correlations published in the literature to predict heat transfer coefficients by comparison experimentally obtained data with appropriate predictions. The results obtained revealed that Hausen and Dittus-Boelter correlations underestimated heat transfer coefficient for the tested PHEx by an order of magnitude. The Aspen Plate code overestimated heat transfer coefficient by about 50%, while Muley-Manglik correlation overestimated it from 1% to 25%, dependent on the value of Reynolds number and hot or cold liquid side.


2016 ◽  
Vol 831 ◽  
pp. 188-197 ◽  
Author(s):  
Janusz T. Cieśliński ◽  
Artur Fiuk ◽  
Wojciech Miciak ◽  
Bartłomiej Siemieńczuk

This study is focused on experimental investigation of a selected type of brazed plate heat exchanger (PHEx). The main aim of the paper was to experimentally check the ability of nanofluids to enhance the performance of PHEx. A typical water-Al2O3 nanofluid was tested and compared to that of the base fluid, i.e. water. Nanoparticles were tested at the concentration of 0.1% and 1% by weight. Impact of the 1 day and 3 days break of operation of the tested PHEx on its performance was of particular interest. Pressure drop in all runs was measured as well. The Wilson approach was applied in order to estimate heat transfer coefficients for the PHEx passages. It was observed, that addition of nanoparticles resulted in deterioration of an overall heat transfer coefficient for the selected PHEx and tested conditions, i.e. temperature range and Reynolds number. Moreover, substantial increase of pressure drop was recorded after each break of operation of the tested PHEx.


2007 ◽  
Vol 72 (8-9) ◽  
pp. 833-846 ◽  
Author(s):  
Emila Djordjevic ◽  
Stephan Kabelac ◽  
Slobodan Serbanovic

In this study the transfer coefficient of evaporation heat of the refrigerant 1,1,1,2-tetrafluoroethane (R-134a) in a vertical plate heat exchanger was experimentally investigated. The results are presented as the dependancy of the mean heat transfer coefficient for the whole heat exchanger on the mean vapor quality. The influences of mass flux, heat flux and flow configuration on the heat transfer coefficient were also taken into account and a comparison with previously published experimental data and literature correlations was made. .


2014 ◽  
Vol 18 (4) ◽  
pp. 1355-1360 ◽  
Author(s):  
Rajavel Rangasamy

An experimental and numerical study of heat transfer and flow characteristics of spiral plate heat exchanger was carried out. The effects of geometrical aspects of the spiral plate heat exchanger and fluid properties on the heat transfer characteristics were also studied. Three spiral plate heat exchangers with different plate spacing (4mm, 5mm and 6 mm) were designed, fabricated and tested. Physical models have been experimented for different process fluids and flow conditions. Water is taken as test fluid. The effect of mass flow rate and Reynolds number on heat transfer coefficient has been studied. Correlation has been developed to predict Nusselt numbers. Numerical models have been simulated using CFD software package FLUENT 6.3.26. The numerical Nusselt number have been calculated and compared with that of experimental Nusselt number.


Sign in / Sign up

Export Citation Format

Share Document