scholarly journals Simultaneous Determination of Six Major Constituents of the Herbal Formula Insampaedok-san Using HPLC-PDA

2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
Chang-Seob Seo ◽  
Jung Hoon Kim ◽  
Hyeun-Kyoo Shin

A simple, rapid, and accurate high-performance liquid chromatographic method was applied to the quantitative analysis of six components of a traditional herbal formulation, Insampaedok-san (ISPDS): liquiritin (1), ferulic acid (2), naringin (3), hesperidin (4), neohesperidin (5), and glycyrrhizin (6). The six components were separated within 35 min using a Gemini C18 column maintained at 40°C. The mobile phase was composed of 1.0% (v/v) aqueous acetic acid (A) and 1.0% (v/v) acetic acid in acetonitrile (B) by gradient elution. The flow rate was 1.0 mL/min and the detector was a photodiode array (PDA) set at 254, 280, and 320 nm. The calibration curves showed good linearity (R2=1.0000) for different concentration ranges. The recovery of each component was in the range of 92.62%–105.96%, with a relative standard deviation (RSD) of less than 4.0%. The RSDs for intra- and interday precision were 0.04%–1.70% and 0.06%–2.56%, respectively. The concentration of each of the six components of ISPDS was in the range 0.72–9.88 mg g−1.

2020 ◽  
Vol 16 (8) ◽  
pp. 1059-1067
Author(s):  
Jéssica Maurício Batista ◽  
Christian Fernandes

Background: Linezolid is a synthetic broad-spectrum antibacterial belonging to the class of oxazolidinones. Linezolid for intravenous infusion is isotonized with dextrose. In acidic environment, the dehydration of dextrose produces furan derivatives, 5-hydroxymethylfurfural (5-HMF) being the main one. The determination of this degradation product is of fundamental importance, since there is evidence it is cytotoxic, genotoxic, mutagenic and carcinogenic. However, there is no official method for the determination of 5-HMF in drug products. Objective: The aim of this study was to develop and validate a high performance liquid chromatographic method to quantify 5-HMF in injection of linezolid. Methods: The chromatographic separation, after optimization, was performed on C18 (150 x 4.6 mm, 5 μm) column. Mobile phase was composed of 14 mM potassium phosphate buffer pH 3.0 ([H+] = 1.0 x 10-3) and methanol in gradient elution at 1.0 mL min-1. The injection volume was 10 μL and detection was performed at 285 nm. Results: The method was optimized and validated, showing selectivity, linearity in the range from 0.075 to 9.0 μg mL-1, precision (RSD ≤ 2.0%), accuracy (mean recovery of 100.07%) and robustness for temperature and pH variation. Conclusion: The method was shown to be adequate to determine 5-HMF in injection containing linezolid in routine analysis.


2009 ◽  
Vol 92 (2) ◽  
pp. 404-409 ◽  
Author(s):  
Abdalla A Elshanawane ◽  
Samia M Mostafa ◽  
Mohamed S Elgawish

Abstract A high-performance liquid chromatographic method was developed for the simultaneous determination of 2 ternary mixtures containing amiloride hydrochloride, atenolol, hydrochlorothiazide, and chlorthalidone used in hypertension therapy. The use of cyanopropyl column results in satisfactory separation of both mixtures. The mobile phase consisted of 10 mM KH2PO4 buffer (pH 4.5) and methanol in a ratio of (75 25 v/v), at a flow rate of 1 mL/min. UV detector was operated at 275 nm. Calibration graphs were linear in the concentration ranges of 210, 20200, 10100, and 550 g/mL for amiloride hydrochloride, atenolol, hydrochlorothiazide, and chlorthalidone, respectively. Intraday and interday precision values (relative standard deviation) were <1.13 for mixture I (amiloride hydrochloride, atenolol, chlorthalidone), and <0.93 for mixture II (amiloride hydrochloride, atenolol, hydrochlorothiazide). The method was successfully applied for the determination of the 2 combinations in laboratory-prepared mixtures and commercial pharmaceutical formulation with high accuracy and precision. Statistical comparison of the results with those of the published methods showed excellent agreement and indicates no significant difference between them.


2009 ◽  
Vol 74 (12) ◽  
pp. 1455-1465 ◽  
Author(s):  
Valéria Guzsvány ◽  
Zsigmond Papp ◽  
Sanja Lazic ◽  
Ferenc Gaál ◽  
Luka Bjelica ◽  
...  

A simple first-order derivative spectrophotometric method was developed for the simultaneous determination of imidacloprid and 6-chloronicotinic acid (6-CNA). By using the zero-crossing approach, imidacloprid was determined at 249 nm and 6-CNA at 236 nm with detection limits of 0.32 and 0.17 ?g mL-1, respectively, and relative standard deviations not exceeding 1.2 % in the case of model systems. The proposed method was applied for the determination of imidacloprid and 6-CNA in commercial formulations. A conventional spectrophotometric method (at 270 nm) was also employed for the determination of the content of imidacloprid in the same commercial formulations. The results of the developed spectrophotometric methods were in good agreement with those obtained by the high-performance liquid chromatographic method.


2013 ◽  
Vol 9 (2) ◽  
pp. 26-29 ◽  
Author(s):  
AK Hemanth Kumar ◽  
V Sudha ◽  
Geetha Ramachandran

A high performance liquid chromatographic method for determination of rifabutin in human plasma was  developed. The method involved deproteinisation of the sample with acetonitrile and analysis of the  supernatant using a reversed-phase C18 column (250mm) and UV detection at a wavelength of 265nm.  The assay was specific for rifabutin and linear from 0.025 to 10.0μg/ml. The relative standard deviation  of intra- and inter-day assays was lower than 10%. The method was able to remove interfering materials  in plasma, yielding an average recovery of rifabutin from plasma of 101%. Due to its simplicity, the assay  can be used for pharmacokinetic studies of rifabutin. SAARC Journal of Tuberculosis, Lung Diseases & HIV/AIDS; 2012; IX(2) 26-29 DOI: http://dx.doi.org/10.3126/saarctb.v9i2.7975


2008 ◽  
Vol 91 (1) ◽  
pp. 67-72 ◽  
Author(s):  
Juliana Sippel ◽  
Letcia L Sfair ◽  
Elfrides E S Schapoval ◽  
Martin Steppe

Abstract A new high-performance liquid chromatographic method was developed and validated for clopidogrel determination in pharmaceutical formulations. The system consisted of an ACE 5 octadecylsilane (C18; 150 4.6 mm id), 5.0 m particle size column; methanol0.1 triethylamine (75 + 25, v/v), pH 5.3, mobile phase at a flow rate of 1.2 mL/min; and a diode array detector set at 220 nm. Specificity, linearity, precision, accuracy, and robustness were the parameters evaluated. The retention time for clopidogrel was 6.8 min. To estimate specificity, an aqueous sample solution was subjected to degradation by ultraviolet light and by acid, alkaline, and oxidation media. The peaks of degradation products did not interfere with the compound signal, and there was no interference when a placebo solution was analyzed. Linearity over a concentration range of 10.0 to 90.0 g/mL was shown (correlation coefficient = 0.9998). Low values of relative standard deviation indicated the adequate intraday and interday precision. The average recovery was found as 99.16. In the robustness test, small modifications to the mobile phase composition did not affect the determination of clopidogrel. The proposed method proved to be simple, fast, and cost efficient for the intended use.


Author(s):  
Saniye Özcan ◽  
Serkan Levent ◽  
Nafiz Öncü Can

: The alkyl esters of p-hydroxybenzoic acid at the C-4 position, “the parabens,” including methyl, ethyl, propyl, and butyl, are widely used as antimicrobial preservatives in foods, cosmetics, and pharmaceuticals. Official regulations on the use of these compounds make their analysis essential for the estimation of their exposure. On this basis, the presented study was realized to develop a simple, selective and cheap high-performance liquid chromatographic method for the quantitative determination of methyl paraben (MP), ethyl paraben (EP), n-propyl paraben (NPP), isopropyl paraben (IPP), n-butyl paraben (NBP), isobutyl paraben (IBP) and benzyl paraben (BP) in pharmaceuticals and cosmetic products. The chromatographic separation of the analytes was achieved under flow rate gradient elution conditions using a C18-bonded core-shell silica particle column (2.6 μm particle size, 150 × 3.0 mm from Phenomenex Co.). The samples were injected into the system as aliquots of 1.0 μL, and the compounds were detected by using a photodiode array detector set at 254 nm wavelength. With this technique, seven paraben derivatives can be determined in the concentration range of 250-2000 ng/mL. The recovery of the method is in the range of 99.95-13.84%, and the RSD is at a maximum value of 3.95%. The proposed method was fully validated and successfully applied to different pharmaceutical and cosmetic samples (n=16), including syrups, suspensions, oral sprays, gels, etc. At least one paraben derivative was detected in six of the samples, and was determined quantitatively. The maximum amount of a paraben derivative found in the analyzed samples is 321.7 ng/mL, which was MP. To the best of our knowledge, this is the first LC method, which is applicable both on pharmaceutical and cosmetic samples.


2009 ◽  
Vol 4 (2) ◽  
pp. 1934578X0900400 ◽  
Author(s):  
Xiao Chi Ma ◽  
Bao Jing Zhang ◽  
Xiu Lan Xin ◽  
Shan Shan Huang ◽  
Sha Deng ◽  
...  

A high-performance liquid chromatographic method was applied to the determination of gamabufotalin, telocinobufagin, bufotalin, cinobufotalin, bufalin, cinobufagin and resibufogenin in three traditional Chinese medicinal preparations containing ChanSu. The compounds were separated on a YMC-C18 column (250 × 4.6 mm, 5 um) with a gradient of acetonitrile and 0.3% aqueous acetic acid ( v / v) at a flow rate of 0.8 mL min−1 and detected at 296 nm. Complete separation was obtained within 35 min for the seven bufadienolides. The calibration curves showed good linearity (r2 > 0.999) within the test range. The recovery was 95.5% - 105.9%. The assay could simultaneously determine seven major bufadienolides of the three Chinese medicinal preparations of ChanSu in 35 min. The results obtained suggested that the developed HPLC assay could be comprehensively utilized for the quality control of the three traditional Chinese medicinal preparations of ChanSu used in the clinic.


Sign in / Sign up

Export Citation Format

Share Document